| 3425 |
|
<p>free of oil- and grease, for inert gas, fuel gas and oxygen, BAM - approved,consisting of: 2 HP double shut-off valve, 2 pressure regulator HR 20 acc. to ISO 7291, BAM - approved with membrabe and HP-contact gauges with inductive-contact, in Ruhestellung geöffnet, bei steigendem Druck schließend, incl. 2 Meter langem, 2 pol. Anschlußkabel, Farbe "blau", Abblaseventile mit montiertem Cu-Rohrbogen (270°, 10x1 mm), 1 change over block and 2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p><p>inlet pressure max: 300 bar<br><br>outlet pressure: 20 bar fixed<br><br>flow max: 170 Nm³/h air at 20 bar outle tpressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 40/20 bar<br><br>width x height x depth: 875 x 325 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
| 6947 |
|
flexible Metall hose with two anti kink springs and anti whip cable assembled complete mounted on hose, length: 1.000 mminlet W21,8x1/14RHf nut acc. to DIN 477-1, No. 6, with 90° angle<br />outlet M20x1,5RHk nut - 12S |
|
|
|
|
| 6948 |
|
free of oil- and grease, acc. to ISO 7291, with metal diaphragm, single stage, with safety gauges acc. to ISO 5171inlet pressure max: 100 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max: 75 Nm³/h compr. air at 20 bar outlet pressure <br />inlet: (rear): M 24x1,5 RHk - S16 nut<br />outlet: G3/4RH x 18mm brazing piece<br />relief valve with mounted copper pipe bend (270 °, 10x1 mm)<br />inlet gauge: 0 – 160/100 bar<br />working gauge: 0 – 40/20 bar<br />width x height x depth: 170 x 200 x 106 mm<br />With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "N", additional sticker on foil: "No cost-free redemption when foil is damaged "<br />The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br />Test report and test report 2.2<br />with sticker "not for oxygen use"<br /><br />Due to the cooling energy evolving from the decompression, the output of the regulator is strongly limited and does not comply with the above mentioned value indicated for the use of compressed air.<br />For continously high flow the additional use of a gas pre heater may be necessary. |
|
|
|
|
| 6949 |
|
<p>acc to DIN EN ISO 2503, class 10, single stage, with double flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 200 bar</p><p>outlet pressure: 1,5 bar pre adjusted<br><br>flow: 2 x 2-23 Nl/min. adjustable<br><br>inlet: W 24,32x1/14 RH nut acc. to DIN 477-1, no. 1<br><br>outlet: 2x G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth: 250 x 230 x 130 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
| 6950 |
|
acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:200 bar<br />outlet pressure: 10 - 200 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 24,32x1/14 RH nut acc. to DIN 477-1, no. 10<br />outlet connection: W24,32x1/14RH male acc. to DIN 477-1, no. 10<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
| 6952 |
|
<p>free of oil- and grease, for inert gas, fuel gas and oxygen, adiabatic compression tested,consisting of: HP double shut-off valve, with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p><p>inlet: M 20x1,5 RHak -12S usuage for 1 cylinder or bundles<br><br>outlet: M 24 x 1.5 RHak - 16S to connect a main pressure regulator<br><br>width x height x depth: 370 x 205 x 160 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", <br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
| 6953 |
|
<p>free of oil- and grease, for inert gas, fuel gas and oxygen, adiabatic compression tested,consisting of:</p><p>1 HP double shut-off valve, <br><br>2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate,<br><br>inlet pressure max: 300 bar<br><br>inlets (bottom): 2 x M 20x1, 5 RHak-12S for operating 2 x 1 cylinder or bundle<br><br>outlet: M 24 x 1.5 RHak - 16S to connect a main pressure regulator<br><br>width x height x depth: 370 x 205 x 160 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", <br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
| 6954 |
|
<p>free of oil- and grease, for inert gas, fuel gas and oxygen, consisting of:</p><p>1 distribution block with an input with sintered filter, non-return valve and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate,<br><br>inlet pressure max: 300 bar<br><br>input (bottom): M 20x1, 5 RHak-12S for operating of cylinder<br><br>outlet (left): M 20x1, 5 RHk-12S nut to connect to a manifold<br><br>outlet (right): M 20x1, 5 RHak-12S to connect to further manifold module <br><br>Width x height x depth: 315x 167 x 110 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
| 6955 |
|
<p>free of oil- and grease, for inert gas, fuel gas and oxygen, consisting of:</p><p>1 distribution block with an input with sintered filter, non-return valve and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate,<br><br>inlet pressure max: 300 bar<br><br>input (bottom): M 20x1, 5 RHak-12S for operating of cylinder<br><br>outlet (right): M 20x1, 5 RHk-12S nut to connect to a manifold<br><br>outlet (left): M 20x1, 5 RHak-12S to connect to further manifold module <br><br>Width x height x depth: 315x 167 x 110 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
| 6956 |
|
<p>free of oil- and grease, for inert gas, fuel gas and oxygen, consisting of:</p><p>1 distribution block with an input with sintered filter, non-return valve and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate,<br><br>inlet pressure max: 300 bar<br><br>input (bottom): M 20x1, 5 RHak-12S for operating of cylinder<br><br>outlet (right): M 20x1, 5 RHk-12S nut to connect to a manifold<br><br>outlet (left): M 20x1, 5 RHak-12S to connect to further manifold module <br><br>Width x height x depth: 915x 167 x 110 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
| 6957 |
|
<p>free of oil- and grease, for inert gas, fuel gas and oxygen, consisting of:</p><p>1 distribution block with an input with sintered filter, non-return valve and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate,<br><br>inlet pressure max: 300 bar<br><br>input (bottom): M 20x1, 5 RHak-12S for operating of cylinder<br><br>outlet (right): M 20x1, 5 RHk-12S nut to connect to a manifold<br><br>outlet (left): M 20x1, 5 RHak-12S to connect to further manifold module <br><br>Width x height x depth: 915 x 167 x 110 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
| 6958 |
|
<p>free of oil- and grease, for oxygen, consisting of: 2 HP shut-off valve, 2 pressure regulator H 40 acc. to ISO 7291, adiabatic compression tested acc. to ISO7291, with metal diaphragm and HP-contact gauges with inductive-contact, 2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p><p>inlet pressure max: 300 bar<br><br>outlet pressure: 28 bar fixed<br><br>flow max: 125 Nm³/h air at 28 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 60/40 bar<br><br>width x height x depth: 875 x 325 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
| 6959 |
|
<p>free of oil- and grease, for oxygen,consisting of: 2 HP shut-off valve, 2 pressure regulator H20 acc to ISO 7291, single stage, adiabatic compression tested acc. to ISO7291, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 1 change over block and 2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p><p>inlet pressure max: 300 bar<br><br>outlet pressure: 15 bar fixed<br><br>flow max: 75 Nm³/h air at 15 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 40/20 bar<br><br>width x height x depth: 875 x 325 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
| 6960 |
|
<p>free of oil- and grease, for oxygen, consisting of: 2 HP shut-off valve, 2 pressure regulator HR 40 acc. to ISO 7291, adiabatic compression tested acc. to ISO7291, with metal diaphragm and HP-contact gauges with inductive-contact, 2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p><p>inlet pressure max: 300 bar<br><br>outlet pressure: 28 bar fixed<br><br>flow max: 250 Nm³/h air at 28 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 60/40 bar<br><br>width x height x depth: 875 x 325 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
| 6963 |
|
<p>free of oil- and grease, for nitrogen and compressed air,consisting of: 2 HP shut-off valve, 2 pressure regulator H40 acc. to ISO 7291, single stage, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 2 solenoid valves 230VAC, 1 double non return valve and 2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p><p>inlet pressure max: 300 bar<br><br>outlet pressure: 40 bar fixed<br><br>flow max: 125 Nm³/h air at 40 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 60/40 bar<br><br>width x height x depth: 1.095 x 325 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "N", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2<br><br>With sticker "Not for oxygen use"</p> |
|
|
|
|
| 6967 |
|
<p>free of oil- and grease, for MISON,consisting of: 2 HP shut-off valve, 2 pressure regulator HR20 acc to ISO 7291, single stage, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 2 solenoid valves 230VAC, 1 double non return valve and 2 distribution blocks, each with an input with sintered filter, non-return valve, connection for a safety valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p><p>inlet pressure max: 300 bar<br><br>outlet pressure: 20 bar fixed<br><br>flow max: 160 Nm³/h air at 20 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 40/20 bar<br><br>width x height x depth: 1095 x 475 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "N", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2<br><br>with warning note:"not to use with oxygen"</p> |
|
|
|
|
| 6968 |
|
<p>free of oil- and grease, for oxygen use, consisting of: 2 HP shut-off valve, 2 pressure regulator HR40 acc. to ISO 7291, adiabatic compression tested acc. to ISO 7291 single stage, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 2 solenoid valves 230VAC, 1 double non return valve and 2 distribution blocks, each with an input with sintered filter, non-return valve, connection for a safety valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p><p>inlet pressure max: 300 bar<br><br>outlet pressure: 25 bar fixed<br><br>flow max: 250 Nm³/h air at 40 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 60/40 bar<br><br>width x height x depth: 1095 x 325 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
| 12684 |
|
Compact single-stage semi-automatic pressure control station (manifold) for two cylinders, designed for technical, medical, corrosive, laboratory and high-purity gases. Features automatic switchover via pressure difference between two connected cylinders — when one cylinder is depleted, the system automatically switches to the full cylinder. Equipped with 2 main single-stage pressure regulators (one per side), inlet and outlet pressure gauges (Ø 50 mm, DIN 837), 50 µm inlet filter and relief valve. Includes 2 stainless steel corrugated metal hoses (1,000 mm) for cylinder connection. Completely mounted on a stainless steel base plate with fixing holes. Inlet: cylinder connection according to DIN 477 Part 1 or Part 5. Outlet: compression fitting or alternatively 1/4" NPT-F thread. Maximum inlet pressure up to 300 bar depending on standard. Outlet pressure ranges from 1.5 to 30 bar; special ranges up to 60 bar. Temperature range: -40 to +70 °C. Body materials: chrome-plated brass, stainless steel or Monel. Diaphragm: stainless steel or Hastelloy. Seat: PCTFE. ECD suitable. Leak rate < 1×10⁻⁸ mbar·l/s (He). ATEX and PED compliant. Options: shut-off or metering valve, purge system, contact gauge or pressure transmitter. |
|
|
|
|
| 12752 |
|
Tessssssst |
|
|
|
|
| 13148 |
|
Single-cylinder manifold station Vulkan LabLine SE 10/2 300 (with standard gauges), chrome-plated. Modular add-on system. Manual switching. Complete on stainless steel base plate: 1× HP shut-off valve, 1× manifold regulator H10/2 double stage acc. to ISO 7291, 1× main shut-off valve, 1× purge valve, 1× cylinder rack. Inlet max 300 bar, outlet 0–10 bar. Max. flow 30 Nm³/h at 10 bar. Stainless steel diaphragm, gas purity up to 5.0. Dimensions: 480 × 280 × 110 mm. |
|
|
|
|