Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
unit_name |
| 12684 |
|
Compact single-stage semi-automatic pressure control station (manifold) for two cylinders, designed for technical, medical, corrosive, laboratory and high-purity gases. Features automatic switchover via pressure difference between two connected cylinders — when one cylinder is depleted, the system automatically switches to the full cylinder. Equipped with 2 main single-stage pressure regulators (one per side), inlet and outlet pressure gauges (Ø 50 mm, DIN 837), 50 µm inlet filter and relief valve. Includes 2 stainless steel corrugated metal hoses (1,000 mm) for cylinder connection. Completely mounted on a stainless steel base plate with fixing holes. Inlet: cylinder connection according to DIN 477 Part 1 or Part 5. Outlet: compression fitting or alternatively 1/4" NPT-F thread. Maximum inlet pressure up to 300 bar depending on standard. Outlet pressure ranges from 1.5 to 30 bar; special ranges up to 60 bar. Temperature range: -40 to +70 °C. Body materials: chrome-plated brass, stainless steel or Monel. Diaphragm: stainless steel or Hastelloy. Seat: PCTFE. ECD suitable. Leak rate < 1×10⁻⁸ mbar·l/s (He). ATEX and PED compliant. Options: shut-off or metering valve, purge system, contact gauge or pressure transmitter. |
|
|
|
|
|
| 12714 |
|
Compact two-stage semi-automatic pressure control station (manifold) for two cylinders, designed for technical, medical, corrosive, laboratory and high-purity gases. Two-stage regulation ensures highly stable outlet pressure. Features automatic switchover via pressure difference — when one cylinder is depleted, the system automatically switches to the full cylinder. Equipped with 2 main two-stage pressure regulators (one per side), inlet and outlet pressure gauges (Ø 50 mm, DIN 837), 50 µm inlet filter and relief valve per stage. Includes 2 stainless steel corrugated metal hoses (1,000 mm) for cylinder connection. Completely mounted on a stainless steel base plate with fixing holes. Inlet: cylinder connection according to DIN 477 Part 1 or Part 5. Outlet: compression fitting or alternatively 1/4" NPT-F thread. Maximum inlet pressure up to 300 bar depending on standard. Outlet pressure ranges from 1.5 to 30 bar; special ranges up to 60 bar. Temperature range: -40 to +70 °C. Body materials: chrome-plated brass, stainless steel or Monel. Diaphragm: stainless steel or Hastelloy. Seat: PCTFE. ECD suitable. Leak rate < 1×10⁻⁸ mbar·l/s (He). ATEX and PED compliant. Options: shut-off or metering valve, purge system, contact gauge or pressure transmitter. |
|
|
|
|
|
| 13162 |
|
Automatic switching manifold Vulkan TecLine AM 35/300 K Effect. Complete on stainless steel base plate including: 2× manifold regulator H20 Effect acc. to ISO 7291 (adiabatic compression tested) 1× in-line regulator AD 35 1× automatic change-over block, 1× main shut-off valve. 2× contact gauges acc. to DIN EN 837-1 with Reed switch. Inlet pressure max 300 bar, outlet pressure 0–10 bar. Max. flow 50 Nm³/h. Diaphragm: PTFE. Dimensions: 530 × 400 × 210 mm. |
|
|
|
|
|
| 13169 |
|
Automatic switching manifold Vulkan TecLine AM 35/300 KH Effect. Complete on stainless steel base plate including: 2× manifold regulator H20 Effect acc. to ISO 7291 (adiabatic compression tested) 1× automatic change-over block, 1× main shut-off valve. 2× contact gauges acc. to DIN EN 837-1 with Reed switch. Inlet pressure max 300 bar, outlet pressure 0–20 bar. Max. flow 75 Nm³/h. Diaphragm: PTFE. Dimensions: 450 × 340 × 210 mm. |
|
|
|
|
|
| 13176 |
|
Automatic switching manifold Vulkan TecLine AM 35/300 H Effect. Complete on stainless steel base plate including: 2× manifold regulator H20 Effect acc. to ISO 7291 (adiabatic compression tested) 1× automatic change-over block, 1× main shut-off valve. Inlet pressure max 300 bar, outlet pressure 0–20 bar. Max. flow 75 Nm³/h. Diaphragm: PTFE. Dimensions: 450 × 340 × 210 mm. |
|
|
|
|
|
| 13183 |
|
Automatic switching manifold Vulkan TecLine AM 40/300 K Effect. Complete on stainless steel base plate including: 2× manifold fin regulator HR40 Effect acc. to ISO 7291 (adiabatic compression tested) 1× automatic change-over block, 1× main shut-off valve. 2× contact gauges acc. to DIN EN 837-1 with Reed switch. Inlet pressure max 300 bar, outlet pressure 0–28 bar. Max. flow 120 Nm³/h. Diaphragm: PTFE. Dimensions: 530 × 400 × 210 mm. |
|
|
|
|
|
| 13190 |
|
Automatic switching manifold Vulkan TecLine AM 40/300 Effect. Complete on stainless steel base plate including: 2× manifold fin regulator HR40 Effect acc. to ISO 7291 (adiabatic compression tested) 1× automatic change-over block, 1× main shut-off valve. Inlet pressure max 300 bar, outlet pressure 0–28 bar. Max. flow 120 Nm³/h. Diaphragm: PTFE. Dimensions: 530 × 400 × 210 mm. |
|
|
|
|
|
| 13197 |
|
Automatic switching manifold Vulkan TecLine AM 45/300 K Effect. Complete on stainless steel base plate including: 2× manifold fin regulator HR20 Effect acc. to ISO 7291 (adiabatic compression tested) 1× automatic change-over block, 1× main shut-off valve. 2× contact gauges acc. to DIN EN 837-1 with Reed switch. Inlet pressure max 300 bar, outlet pressure 0–20 bar. Max. flow 170 Nm³/h. Diaphragm: PTFE. Dimensions: 500 × 370 × 230 mm. |
|
|
|
|
|
| 13204 |
|
Automatic switching manifold Vulkan TecLine AM 45/300 Effect. Complete on stainless steel base plate including: 2× manifold fin regulator HR20 Effect acc. to ISO 7291 (adiabatic compression tested) 1× automatic change-over block, 1× main shut-off valve. Inlet pressure max 300 bar, outlet pressure 0–20 bar. Max. flow 170 Nm³/h. Diaphragm: PTFE. Dimensions: 500 × 370 × 230 mm. |
|
|
|
|
|
| 13211 |
|
Automatic switching manifold Vulkan TecLine AM 55/300 K Effect. Complete on stainless steel base plate including: 2× manifold fin regulator HR40 Effect acc. to ISO 7291 (adiabatic compression tested) 1× automatic change-over block, 1× main shut-off valve. 2× contact gauges acc. to DIN EN 837-1 with Reed switch. Inlet pressure max 300 bar, outlet pressure 0–28 bar. Max. flow 250 Nm³/h. Diaphragm: Rubber (SS for O₂). Dimensions: 500 × 380 × 230 mm. |
|
|
|
|
|
| 13218 |
|
Automatic switching manifold Vulkan TecLine AM 55/300 Effect. Complete on stainless steel base plate including: 2× manifold fin regulator HR40 Effect acc. to ISO 7291 (adiabatic compression tested) 1× automatic change-over block, 1× main shut-off valve. Inlet pressure max 300 bar, outlet pressure 0–28 bar. Max. flow 250 Nm³/h. Diaphragm: Rubber (SS for O₂). Dimensions: 500 × 380 × 230 mm. |
|
|
|
|
|
| 13225 |
|
Automatic switching manifold Vulkan TecLine AM 35/300 KM Effect. Complete on stainless steel base plate including: 2× manifold regulator H20 Effect acc. to ISO 7291 (adiabatic compression tested) 1× in-line regulator AD 35 2× solenoid valves 24V AC, normally closed 1× automatic change-over block, 1× main shut-off valve. 2× contact gauges acc. to DIN EN 837-1 with Reed switch. Inlet pressure max 300 bar, outlet pressure 0–10 bar. Max. flow 50 Nm³/h. Diaphragm: PTFE. Dimensions: 690 × 430 × 210 mm. |
|
|
|
|
|
| 13232 |
|
Automatic switching manifold Vulkan TecLine AM 35/300 KHM Effect. Complete on stainless steel base plate including: 2× manifold regulator H20 Effect acc. to ISO 7291 (adiabatic compression tested) 2× solenoid valves 24V AC, normally closed 1× automatic change-over block, 1× main shut-off valve. 2× contact gauges acc. to DIN EN 837-1 with Reed switch. Inlet pressure max 300 bar, outlet pressure 0–20 bar. Max. flow 75 Nm³/h. Diaphragm: PTFE. Dimensions: 690 × 350 × 210 mm. |
|
|
|
|
|
| 13239 |
|
Automatic switching manifold Vulkan TecLine AM 40/300 KM Effect. Complete on stainless steel base plate including: 2× manifold regulator H40 Effect acc. to ISO 7291 (adiabatic compression tested) 2× solenoid valves 24V AC, normally closed 1× automatic change-over block, 1× main shut-off valve. 2× contact gauges acc. to DIN EN 837-1 with Reed switch. Inlet pressure max 300 bar, outlet pressure 0–40 bar. Max. flow 120 Nm³/h. Diaphragm: PTFE (SS for O₂). Dimensions: 690 × 350 × 210 mm. |
|
|
|
|
|
| 13246 |
|
Automatic switching manifold Vulkan TecLine AM 45/300 KM Effect. Complete on stainless steel base plate including: 2× manifold fin regulator HR20 Effect acc. to ISO 7291 (adiabatic compression tested) 2× solenoid valves 24V AC, normally closed 1× automatic change-over block, 1× main shut-off valve. 2× contact gauges acc. to DIN EN 837-1 with Reed switch. Inlet pressure max 300 bar, outlet pressure 0–20 bar. Max. flow 170 Nm³/h. Diaphragm: Rubber. Dimensions: 720 × 385 × 210 mm. |
|
|
|
|
|
| 13253 |
|
Automatic switching manifold Vulkan TecLine AM 55/300 KM Effect. Complete on stainless steel base plate including: 2× manifold fin regulator HR40 Effect acc. to ISO 7291 (adiabatic compression tested) 2× solenoid valves 24V AC, normally closed 1× automatic change-over block, 1× main shut-off valve. 2× contact gauges acc. to DIN EN 837-1 with Reed switch. Inlet pressure max 300 bar, outlet pressure 0–40 bar. Max. flow 250 Nm³/h. Diaphragm: Rubber (SS for O₂). Dimensions: 720 × 385 × 210 mm. |
|
|
|
|
|
| 13260 |
|
Automatic switching manifold Vulkan LabLine AM 35/300 Effect, chrome-plated. Complete on stainless steel base plate: 2× manifold regulator H20 Effect acc. to ISO 7291, 2× ND-purge valves, 1× in-line regulator AD 35, 1× automatic change-over block, 1× main shut-off valve, without contact gauge. Inlet max 300 bar, outlet 0–10 bar, max flow 50 Nm³/h at 10 bar. Stainless steel diaphragm, gas purity up to 5.0. Dimensions: 450 × 420 × 210 mm. |
|
|
|
|
|
| 13267 |
|
Automatic switching manifold Vulkan LabLine AM 35/300 K Effect, chrome-plated. Complete on stainless steel base plate: 2× manifold regulator H20 Effect acc. to ISO 7291, 2× ND-purge valves, 1× in-line regulator AD 35, 1× automatic change-over block, 1× main shut-off valve, 2× contact gauges with Reed switch. Inlet max 300 bar, outlet 0–10 bar, max flow 50 Nm³/h at 10 bar. Stainless steel diaphragm, gas purity up to 5.0. Dimensions: 450 × 420 × 210 mm. |
|
|
|
|
|
| 13302 |
|
Connecting pipe Vareo VB 90° bent, 2 × 150 mm. Copper tube, DN10, PN300. Inlet: M 24×1.5 RH U-nut. Outlet: M 24×1.5 RH U-nut. Manifold station → base station, for cylinders. |
|
|
|
|
|
| 13303 |
|
Connecting pipe Vareo VB 90° bent Acetylene, 2 × 150 mm. Steel tube, DN10, PN300. Inlet: M 24×1.5 RH U-nut. Outlet: W 21.8×1/14 LH U-nut. Manifold station → base station, for cylinders. |
|
|
|
|
|
| 13306 |
|
Connecting pipe Vareo VF straight, 400 mm. Copper tube, DN10, PN300. Inlet: M 24×1.5 RH U-nut. Outlet: M 24×1.5 RH U-nut. Between two manifold stations, for cylinders. |
|
|
|
|
|
| 13307 |
|
Connecting pipe Vareo VF straight Acetylene, 400 mm. Steel tube, DN10, PN26. Inlet: M 24×1.5 RH U-nut. Outlet: M 24×1.5 RH U-nut. Between two manifold stations, for cylinders. |
|
|
|
|
|
| 13308 |
|
Connecting pipe Vareo VBP 90° bent, 900 × 150 mm. Copper tube, DN10, PN300. Inlet: M 24×1.5 RH U-nut. Outlet: M 24×1.5 RH U-nut. Manifold station → base station, for bundles. |
|
|
|
|
|
| 13309 |
|
Connecting pipe Vareo VBP 90° bent Acetylene, 900 × 150 mm. Steel tube, DN10, PN300. Inlet: M 24×1.5 RH U-nut. Outlet: M 24×1.5 RH U-nut. Manifold station → base station, for bundles. |
|
|
|
|
|