Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
unit_name |
| 22 |
|
<p>In-line dome pressure reducer Vulkan LD1 MD on both sides. G 1 RHi, single-stage design, without pressure gauge. Maximum inlet pressure: 100 bar (oxygen max. 40 bar!). Output pressure: 0.5 - 99 bar adjustable (oxygen 0.5 - 39 bar!). Maximum output: 2,400 Nm³/h (oxygen 2,100 Nm³/h). Inlet and outlet: G1RHi. Width x height x depth: 130 x 170 x 130 mm. Optionally also available with control pressure reducer. Available for various gas types (please select in the selection window!): Oxygen: Item No. 108535 (pe max. 40 bar pa 0.5 - 39 bar!). CO2/Argon: Item No. 106535. Helium: Item No. 10653526Nitrogen: Item no. 103535Hydrogen: Item no. 104535Compressed air: Item no. 107535</p> |
|
|
|
|
|
| 23 |
|
<p>In-line dome pressure reducer Vulkan LD1 MD on both sides. G 1 RHi, single-stage design, without pressure gauge. Maximum inlet pressure: 100 bar (oxygen max. 40 bar!). Output pressure: 0.5 - 99 bar adjustable (oxygen 0.5 - 39 bar!). Maximum output: 2,400 Nm³/h (oxygen 2,100 Nm³/h). Inlet and outlet: G1RHi. Width x height x depth: 130 x 170 x 130 mm. Optionally also available with control pressure reducer. Available for various gas types (please select in the selection window!): Oxygen: Item No. 108535 (pe max. 40 bar pa 0.5 - 39 bar!). CO2/Argon: Item No. 106535. Helium: Item No. 10653526Nitrogen: Item no. 103535Hydrogen: Item no. 104535Compressed air: Item no. 107535</p> |
|
|
|
|
|
| 24 |
|
<p>In-line dome pressure reducer Vulkan LD1 MD on both sides. G 1 RHi, single-stage design, without pressure gauge. Maximum inlet pressure: 100 bar (oxygen max. 40 bar!). Output pressure: 0.5 - 99 bar adjustable (oxygen 0.5 - 39 bar!). Maximum output: 2,400 Nm³/h (oxygen 2,100 Nm³/h). Inlet and outlet: G1RHi. Width x height x depth: 130 x 170 x 130 mm. Optionally also available with control pressure reducer. Available for various gas types (please select in the selection window!): Oxygen: Item No. 108535 (pe max. 40 bar pa 0.5 - 39 bar!). CO2/Argon: Item No. 106535. Helium: Item No. 10653526Nitrogen: Item no. 103535Hydrogen: Item no. 104535Compressed air: Item no. 107535</p> |
|
|
|
|
|
| 1334 |
|
Vulkan LDS1 PN25 line dome pressure reducer with control pressure reducer, complete with control pressure reducer, material: brass/Viton, single-stage design, maximum inlet pressure: 25 bar, output pressure: 0.5 – 16 bar adjustable, maximum output: 1,100 Nm³/h air at 16 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
|
| 1335 |
|
Vulkan LDS1 PN25 line dome pressure reducer with control pressure reducer, complete with control pressure reducer, material: brass/Viton, single-stage design, maximum inlet pressure: 25 bar, output pressure: 0.5 – 16 bar adjustable, maximum output: 1,100 Nm³/h air at 16 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
|
| 1336 |
|
Vulkan LDS1 PN25 line dome pressure reducer with control pressure reducer, complete with control pressure reducer, material: brass/Viton, single-stage design, maximum inlet pressure: 25 bar, output pressure: 0.5 – 16 bar adjustable, maximum output: 1,100 Nm³/h air at 16 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
|
| 1337 |
|
Vulkan LDS1 PN25 line dome pressure reducer with control pressure reducer, complete with control pressure reducer, material: brass/Viton, single-stage design, maximum inlet pressure: 25 bar, output pressure: 0.5 – 16 bar adjustable, maximum output: 1,100 Nm³/h air at 16 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
|
| 1338 |
|
Vulkan LDS1 PN25 line dome pressure reducer with control pressure reducer, complete with control pressure reducer, material: brass/Viton, single-stage design, maximum inlet pressure: 25 bar, output pressure: 0.5 – 16 bar adjustable, maximum output: 1,100 Nm³/h air at 16 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
|
| 1339 |
|
Vulkan LDS1 PN25 line dome pressure reducer with control pressure reducer, complete with control pressure reducer, material: brass/Viton, single-stage design, maximum inlet pressure: 25 bar, output pressure: 0.5 – 16 bar adjustable, maximum output: 1,100 Nm³/h air at 16 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
|
| 1340 |
|
Vulkan LDS1 PN25 line dome pressure reducer with control pressure reducer, complete with control pressure reducer, material: brass/Viton, single-stage design, maximum inlet pressure: 25 bar, output pressure: 0.5 – 16 bar adjustable, maximum output: 1,100 Nm³/h air at 16 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
|
| 1341 |
|
Vulkan LDS1 PN25 line dome pressure reducer with control pressure reducer, complete with control pressure reducer, material: brass/Viton, single-stage design, maximum inlet pressure: 25 bar, output pressure: 0.5 – 16 bar adjustable, maximum output: 1,100 Nm³/h air at 16 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
|
| 1342 |
|
Vulkan LDS1 PN25 line dome pressure reducer with control pressure reducer, complete with control pressure reducer, material: brass/Viton, single-stage design, maximum inlet pressure: 25 bar, output pressure: 0.5 – 16 bar adjustable, maximum output: 1,100 Nm³/h air at 16 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
|
| 1343 |
|
Vulkan LDS1 PN25 line dome pressure reducer with control pressure reducer, complete with control pressure reducer, material: brass/Viton, single-stage design, maximum inlet pressure: 25 bar, output pressure: 0.5 – 16 bar adjustable, maximum output: 1,100 Nm³/h air at 16 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
|
| 1344 |
|
Vulkan LDS1 PN25 line dome pressure reducer with control pressure reducer, complete with control pressure reducer, material: brass/Viton, single-stage design, maximum inlet pressure: 25 bar, output pressure: 0.5 – 16 bar adjustable, maximum output: 1,100 Nm³/h air at 16 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
|
| 1355 |
|
Vulkan LDS1 PN25 line dome pressure reducer with control pressure reducer, complete with control pressure reducer, material: brass/Viton, single-stage design, maximum inlet pressure: 25 bar, output pressure: 0.5 – 16 bar adjustable, maximum output: 1,100 Nm³/h air at 16 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
|
| 3426 |
|
<p>acc. to DIN EN ISO 2503, class 20, single stage, with double flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valvesinlet pressure max: 200 bar</p><p>outlet pressure: 2x 2,5 bar pre adjusted<br><br>flow: 2 x 3,0 - 30,0 Nl/min. adjustable<br><br>inlet: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br><br>outlet: 2x G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth: 250 x 230 x 130 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape<br><br><br><br>Replaces article 2264551189</p> |
|
|
|
|
|
| 3427 |
|
<p>acc to DIN EN ISO 2503, class 10, single stage, with double flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 200 bar</p><p>outlet pressure: 1,5 bar pre adjusted<br><br>flow: 2 x 4 – 42 Nl/min. adjustable<br><br>inlet: W 24,32x1/14 RH nut acc. to DIN 477-1, no. 10<br><br>outlet: 2x G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth: 250 x 230 x 130 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3428 |
|
according to drawing no. 95 100 130, with inlet pressure gauge and shut-off valve,Inlet pressure max: 12 bar<br />Outlet pressure: fixed at approx. 0.5 - 0.7 bar<br />Inlet: 7/16" x 28 NS2<br />Output: compression fitting 4 mm Ms nickel-plated<br />Inlet pressure gauge: 0 - 16 bar<br />Output pressure gauge: without (no connection available)<br />With flyer provided by Linde - Linde #43586000<br />Accessory pack: bag with 3 O-rings #11207000<br /><br />Minimum order quantity 300 pieces |
|
|
|
|
|
| 3431 |
|
<p>acc. ISO 7291, single stage, with safety pressure gauges acc. ISO 5171</p><p>inlet pressure max: 25 bar<br><br>outlet pressure: 0 – 1,5 bar regelbar<br><br>Flow max: 18 Nm³/h at 1,5 bar outlet pressure <br><br>inlet connection: M24x1,5RHak male<br><br>outlet connection: M24x1,5RHak male<br><br>inlet pressure gauge: 0 – 40/ 25 bar<br><br>outlet pressure gauge: 0 – 2,5/ 1,5 bar<br><br>Width x heighth x depth: 232 x 185 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape and certificate 2.2</p> |
|
|
|
|
|
| 3432 |
|
<p>appropriate electrical equipment,marking: Ex II 1 G D [EEx ia] IIC, </p><p>to alarm and control in case of pressure drop, to connect 2 solenoid valves (230v 50Hz) and contact gauges with inductive contact, with integrated optical and acoustical signal, connection of additional external alarm possible, complete in box with potential free contact to connect contact gauges in explosive areas of group II, <br><br>box must be installed outside the explosive area, <br><br>power supply: 230V/ 50Hz</p> |
|
|
|
|
|
| 3433 |
|
<p>for connecting, monitoring and switching two contact pressure gauges with inductive contacts and two solenoid valves, with internal signal display "Gas type operation OK empty" for each channel, extraction side selectable, with "Empty message hold function" (alarm must be acknowledged),Inputs: 2 x inductive contact</p><p>Output: 2 x solenoid valve 230V 50Hz<br><br>with potential-free contacts,<br><br>completely in plastic housing<br><br>Width x height x depth: 300 x 230 x 190 mm<br><br>With operating instructions, CE declaration of conformity for the electrical part, electr. Execution according to current VDE and European regulations, affixed type plate with Linde logo, glass front pane with Linde logo, Linde type designation, affixed Linde lettering, individually packed in a carton, with Linde adhesive tape</p> |
|
|
|
|
|
| 3435 |
|
single stage with safety gauge acc. to ISO 5171, inlet pressure max: 20 bar<br />outlet pressure: 0 – 4 bar adjustable<br />flow max: 10 kg/h at 4 bar working pressure<br />inlet: W 21,8x1/14 LH nut acc. to DIN 477<br />outlet: G 3/8 LHk x 9 mm tail-piece EN 560<br />outlet gauge: 0 – 6/4 bar<br />width x height x depth: 198 x 134 x 75 mm<br />with Linde-Logo on body, with Linde-tape and Linde operating manual<br /> |
|
|
|
|
|
| 3439 |
|
acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,<br />with shut off valve<br />inlet pressure max:200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />flow max:48 Nm³/h air at 10 bar outlet pressure <br />inlet connection: W 24,32x1/14 RH nut acc. to DIN 477-1, no. 10<br />outlet connection: G 1/4RH x 6mm tail-piece acc. EN560<br />inlet gauge: 0 – 315 /200 bar<br />working gauge: 0 – 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3440 |
|
<p>acc to DIN EN ISO 2503, class 3, double stage, with safety gauges acc. to DIN ISO 5171, with shut off valve</p><p>inlet pressure max: 200 bar<br><br>outlet pressure: 0 – 10 bar adjustable<br><br>flow max: 28 Nm³/h air at 10 bar outlet pressure <br><br>inlet: W24,32x1/14RH nut acc. to DIN 477-1, no. 10<br><br>outlet: G 1/4 RHk male with 6mm tail-piece,<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 16/10 bar<br><br>width x height x depth: 240 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3441 |
|
according to DIN EN ISO 2503, with inlet pressure compensation for constant downstream pressure when the inlet pressure falls, with safety pressure gauges in accordance with ISO 5171, with shut-off valveInput pressure max: 200 bar<br />Output pressure: 0 – 30.0 bar<br />Performance: 40 Nm³/h compressed air at 30 bar back pressure<br />Input: W 24.32x1/14 RH Ü-nut according to DIN 477-1, No. 10<br />Output: G 3/8 RHk x 9 mm hose nozzle according to EN 560<br />Input pressure gauge: 0 – 315/200 bar<br />Output pressure gauge: 0 - 60/40 bar<br />Width x Height x Depth: 210 x 230 x 75 mm<br />with Linde logo on the housing, with Linde operating instructions and Linde adhesive tape |
|
|
|
|
|
| 3442 |
|
<p>acc to DIN EN ISO 2503 class 0, double stage, with safety gauges acc. to DIN ISO 5171, including shut off valve</p><p>inlet pressure max: 200 bar<br><br>outlet pressure: 0 – 1,5 bar adjustable<br><br>flow max: 5 Nm³/h air at 1,5 bar outlet pressure <br><br>inlet: W24,32x1/14RH nut acc. to DIN 477-1, no. 10<br><br>outlet: G 1/4 RHk male with 6 mm tail-piece,<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 2,5/1,5 bar<br><br>width x height x depth: 240 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3443 |
|
acc. to ISO 2503, class 5, single stage, with high pressure compensation for constant working pressure, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 200 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max.: 75 Nm³/h air at 10 bar working pressure<br />Inlet connection: W24,32x1/14RH nut acc. to DIN 477-1, no. 10<br />outlet connection: G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 315/200 bar<br />working gauge: 0 - 40/20 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3444 |
|
acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max:200 bar<br />outlet pressure: 0 – 40 bar adjustable<br />flow max: 120 Nm³/h at 40 bar working pressure<br />inlet connection: W24,32x1/14RHf nut acc. to DIN 477-1, no. 10<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 60/40 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3445 |
|
acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max:200 bar<br />outlet pressure: 0 – 60 bar adjustable<br />flow max: 140 Nm³/h at 60 bar working pressure<br />inlet connection: W24,32x1/14 RHf nut acc. to DIN 477-1, no. 10<br />outlet connection: G 1/4RHak acc. to EN560<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 100/60 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3446 |
|
<p>acc. to ISO 2503, class 3, single stage, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 200 bar<br>outlet pressure: 0 – 10 bar adjustable<br>flow max.: 48 Nm³/h air at 10 bar working pressure<br>Inlet connection: M19x1,5 LH nut acc. to DIN 477-1, no. 14<br>outlet connection:G 3/8 RHk x 9 mm tailpiece acc. to EN 560<br>inlet gauge: 0 - 315/200 bar<br>working gauge: 0 - 16/10 bar<br>width x height x depth: 210 x 190 x 75 mm<br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3447 |
|
acc. to ISO 2503, class 3, single stage, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />flow max.: 48 Nm³/h air at 10 bar working pressure<br />Inlet connection: W21,8x1/14LH nut acc. to DIN 477-1, no. 1<br />outlet connection:G 3/8 RHk x 9 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 315/200 bar<br />working gauge: 0 - 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3448 |
|
<p>acc to DIN EN ISO 2503, class 3, double stage, with safety gauges acc. to DIN ISO 5171</p><p>inlet pressure max: 200 bar<br><br>outlet pressure: 0 – 10 bar adjustable<br><br>flow max: 28 Nm³/h air at 10 bar outlet pressure <br><br>inlet: W21,8x1/14LH nut acc. to DIN 477-1, no. 1<br><br>outlet: G 3/8 LHk male with 9mm tail-piece,<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 16/10 bar<br><br>width x height x depth: 240 x 190 x 75 mm</p> |
|
|
|
|
|
| 3449 |
|
acc. to ISO 2503, class 5, single stage, with high pressure compensation for constant working pressure, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 200 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max.: 75 Nm³/h air at 10 bar working pressure<br />Inlet connection: W21,8x1/14LH nut acc. to DIN 477-1, no. 1<br />outlet connection: G 3/8 LHk x 9 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 315/200 bar<br />working gauge: 0 - 40/20 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3450 |
|
acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max:200 bar<br />outlet pressure: 0 – 40 bar adjustable<br />flow max: 120 Nm³/h at 40 bar working pressure<br />inlet connection: W21,8x1/14LHf nut acc. to DIN 477-1, no. 1<br />outlet connection: G 3/8LH x 9mm tail-piece<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 60/40 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3451 |
|
acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max:200 bar<br />outlet pressure: 0 – 60 bar adjustable<br />flow max: 140 Nm³/h at 60 bar working pressure<br />inlet connection: W21,8x1/14LHf nut acc. to DIN 477-1, no. 1<br />outlet connection: G 3/8LHak acc. to EN560<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 100/60 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3452 |
|
<p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,</p><p>with shut off valve<br><br>inlet pressure max: 200 bar<br><br>outlet pressure: 0 - 30 Nl/min. (0 – 10 bar) adjustable<br><br>flow max: 30 Nl/min. at 10 bar outlet pressure <br><br>inlet connection: W 21,8x1/14 LH nut acc. to DIN 477-1, no. 1<br><br>outlet connection: G 3/8 LHk x 9 mm tail-piece acc. EN560<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 30 Nl/min.<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3453 |
|
<p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,</p><p>with shut off valve<br><br>inlet pressure max: 200 bar<br><br>outlet pressure: 0 - 50 Nl/min. (0 – 10 bar) adjustable<br><br>flow max: 50 Nl/min. at 10 bar outlet pressure <br><br>inlet connection: W 21,8x1/14 LH nut acc. to DIN 477-1, no. 1<br><br>outlet connection: G 3/8 LHk x 9 mm tail-piece acc. EN560<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 50 Nl/min.<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3454 |
|
acc to DIN EN ISO 2503, class 3, with high pressure compensation for constant working pressure, single stage, with shut off valve, with safety gauges acc. to ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />Flow max: 48 Nm³/h compressed air at 10 bar working pressure<br />inlet: W 21,8x1/14 RH Ü-Mutter nach DIN 477-1, No. 6<br />outlet:G 1/4 RHk x 6 mm tail-piece acc. to EN 560<br />inlet gauge: 0 – 315/200 bar<br />outlet gauge: 0 – 16/10 bar<br />width x hight x depth: 210 x 190 x 75 mm<br />with metal diaphragm, 5m hose #400 206 01, 2 hose clamp VA #400 223, 1 tail piece #402 003, 1 nut #402 021, 1 cylinder rack #410 040 01, complete blistered with label "free of oil and grease" with operating manual Linde in box |
|
|
|
|
|
| 3455 |
|
acc to DIN EN ISO 2503, class 3, with high pressure compensation for constant working pressure, single stage, with shut off valve, with safety gauges acc. to ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />Flow max: 48 Nm³/h compressed air at 10 bar working pressure<br />inlet: W 24,32x1/14 RH Ü-Mutter nach DIN 477-1, No. 10<br />Ausgang:G 1/4 RHk x 6 mm Tülle nach EN 560<br />outlet:G 1/4 RHk x 6 mm tail-piece acc. to EN 560<br />inlet gauge:0 – 315/200 bar<br />outlet gauge: 0 – 16/10 bar<br />width x hight x depth: 210 x 190 x 75 mm<br />with metal diaphragm, 5m hose #400 206 01, 2 hose clamp VA #400 223, 1 tail piece #402 003, 1 nut #402 021, 1 cylinder rack #410 040 01, complete blistered with label "free of oil and grease" with operating manual Linde in box |
|
|
|
|
|
| 3456 |
|
<p>acc to DIN EN ISO 2503, class 5, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar</p><p>outlet pressure: 0 – 20 bar adjustable<br><br>flow max: 75 Nm³/h at 20 bar working pressure<br><br>inlet connection: W21,8x1/14RHf nut acc. to DIN 477-1, no. 6<br><br>outlet connection: G 1/4RH x 6mm tail-piece<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 40/ 20 bar<br><br>width x height x depth: 210 x 210 x 75 mm</p> |
|
|
|
|
|
| 3457 |
|
<p>acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar</p><p>outlet pressure: 0 – 40 bar adjustable<br><br>flow max: 120 Nm³/h at 40 bar working pressure<br><br>inlet connection: W21,8x1/14RHf nut acc. to DIN 477-1, no. 6<br><br>outlet connection: G 1/4RH x 6mm tail-piece<br><br>inlet gauge: 0 – 315/200 bar<br><br>working gauge: 0 – 60/40 bar<br><br>width x height x depth: 210 x 210 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3458 |
|
<p>acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar</p><p>outlet pressure: 0 – 60 bar adjustable<br><br>flow max: 140 Nm³/h at 60 bar working pressure<br><br>inlet connection: W21,8x1/14 RHf nut acc. to DIN 477-1, no. 6<br><br>outlet connection: G 1/4RHak acc. to EN560<br><br>inlet gauge: 0 – 315/200 bar<br><br>working gauge: 0 – 100/60 bar<br><br>width x height x depth: 210 x 210 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3459 |
|
acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:200 bar<br />outlet pressure: 10 - 200 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: W 21,8x1/14 RH male DIN 477-1, no. 6<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3460 |
|
compressed air, acc. to ISO 2503, class 3, single stage, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />flow max.: 48 Nm³/h air at 10 bar working pressure<br />Inlet connection: G 5/8 RH screw acc. to DIN 477-1, no. 13<br />outlet connection:G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 315/200 bar<br />working gauge: 0 - 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3461 |
|
acc. to ISO 2503, class 5, single stage, with high pressure compensation for constant working pressure, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 200 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max.: 75 Nm³/h air at 10 bar working pressure<br />Inlet connection: G5/8RH screw acc. to DIN 477-1, no. 13<br />outlet connection: G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 315/200 bar<br />working gauge: 0 - 40/20 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3462 |
|
acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max:200 bar<br />outlet pressure: 0 – 40 bar adjustable<br />flow max: 120 Nm³/h at 40 bar working pressure<br />inlet connection: G5/8RH screw acc. to DIN 477-1, no. 13<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 60/40 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3463 |
|
acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max:200 bar<br />outlet pressure: 0 – 60 bar adjustable<br />flow max: 140 Nm³/h at 60 bar working pressure<br />inlet connection: G5/8RH screw acc. to DIN 477-1, no. 13<br />outlet connection: G 1/4RH acc. to EN560<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 100/60 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3464 |
|
acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:200 bar<br />outlet pressure: 10 - 200 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />Inlet connection: G 5/8 RHaf screw acc. to DIN 477-1, no. 13<br />Outlet connection: G 5/8 RHif acc. to DIN 477-1, no. 13<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3465 |
|
acc to DIN EN ISO 2503, class 3, single stage, adiabatic compression tested acc. to DIN EN ISO 2503,with safety gauges acc. to DIN ISO 5171<br />inlet pressure max:200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />flow max:48 Nm³/h air at 10 bar outlet pressure <br />inlet connection: G ¾ RH nut acc. to DIN 477<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 315 /200 bar<br />working gauge: 0 – 16/ 10 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3466 |
|
acc to DIN EN ISO 2503, class 3, with high pressure compensation for constant working pressure, single stage, with shut off valve, with safety gauges acc. to ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0 – 10 bar adjustable<br />Flow max: 48 Nm³/h compressed air at 10 bar working pressure<br />inlet: G3/4 RH Ü-Mutter nach DIN 477-1, No. 9<br />outlet:G 1/4 RHk x 6 mm tail-piece acc. to EN 560<br />inlet gauge: 0 – 315/200 bar<br />outlet gauge: 0 – 16/10 bar<br />width x hight x depth: 210 x 190 x 75 mm<br />with metal diaphragm, 5m hose #400 206 01, 2 hose clamp VA #400 223, 1 tail piece #402 003, 1 nut #402 021, 1 cylinder rack #410 040 01, complete blistered with label "free of oil and grease" with operating manual Linde in box |
|
|
|
|
|
| 3467 |
|
<p>acc to DIN EN ISO 2503,class 3, double stage, adiabatic compression tested acc. to DIN EN ISO 2503,with safety gauges acc. to DIN ISO 5171</p><p>inlet pressure max: 200 bar<br><br>outlet pressure: 0 – 10 bar adjustable<br><br>flow max: 28 Nm³/h air at 10 bar outlet pressure <br><br>inlet: G3/4RH nut acc. to DIN 477-1, no. 9<br><br>outlet: G 1/4 RHk male with 6mm tail-piece,<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 16/10 bar<br><br>width x height x depth: 240 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3468 |
|
<p>nach ISO 2503, Klasse 5, zweistufige Bauart, mit Vordruckausgleich für konstanten Hinterdruck bei fallendem Vordruck, mit Sicherheitsmanometern nach ISO 5171, mit AbsperrventilEingangsdruck max: 200 bar</p><p>Ausgangsdruck: 0 – 20 bar regelbar<br><br>Leistung max: 60 Nm³/h Druckluft bei 20 bar Hinterdruck <br><br>Eingang: G 3/4 RH Ü-Mutter nach DIN 477-1<br><br>Ausgang:G 3/8 RHk x 9 mm Tülle nach EN 560<br><br>Eingangsmanometer:0 – 315/200 bar<br><br>Ausgangsmanometer: 0 – 40/20 bar<br><br>Breite x Höhe x Tiefe: 240 x 210 x 75 mm<br><br>mit Linde-Logo auf Gehäuse, mit Linde-Bedienungsanleitung und Linde-Klebeband</p> |
|
|
|
|
|
| 3469 |
|
acc to DIN EN ISO 2503, class 5, single stage, adiabatic compression tested acc. to DIN EN ISO 2503, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max:200 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max: 75 Nm³/h at 20 bar working pressure<br />inlet connection: G3/4 RHf nut acc. to DIN 477-1, no. 9<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 315 /200 bar<br />working gauge: 0 – 40/ 20 bar<br />width x height x depth: 210 x 210 x 75 mm |
|
|
|
|
|
| 3470 |
|
acc. to ISO 2503, single stage with safety gauges acc. to ISO 5171inlet pressure max:200 bar<br />outlet pressure: 10 - 200 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: G3/4 RH nut acc. to DIN 477-1, no. 9<br />outlet connection: G 3/4 RH male acc. to DIN 477-1, no. 9<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 150 x 210 x 120 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3471 |
|
acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure, with metal diaphragm, with safety gauges acc. to DIN ISO 5171inlet pressure max:200 bar<br />outlet pressure: 0 – 40 bar adjustable<br />flow max: 120 Nm³/h at 40 bar working pressure<br />inlet connection: G3/4RHf nut acc. to DIN 477-1, no. 9<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 60/40 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3472 |
|
acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure, with metal diaphragm, with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0 – 60 bar adjustable<br />flow max:140 Nm³/h at 60 bar working pressure<br />inlet connection: G3/4 RHf nut acc. to DIN 477-1, no. 9<br />outlet connection: G 1/4RHak acc. to EN560<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 100/60 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3473 |
|
<p>acc to DIN EN ISO 2503, class 10, single stage, with flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 200 bar</p><p>outlet pressure: 4 bar pre adjusted<br><br>flow: 8,5 - 85 Nl/min. adjustable<br><br>inlet: W 24,32x1/14 RH nut acc. to DIN 477-1, no. 10<br><br>outlet: G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth:: 210 x 230 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3474 |
|
<p>acc to ISO 2503, class 20, single stage, with flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 200 bar</p><p>outlet pressure: 4,5 bar pre adjusted<br><br>flow: 5,0 – 50,0 Nl/min. adjustable<br><br>inlet: W 24,32x1/14 RH nut acc. to DIN 477-1<br><br>outlet: G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth:: 210 x 230 x 75 mm<br><br><br><br>replaces item 223615</p> |
|
|
|
|
|
| 3475 |
|
acc to DIN EN ISO 2503, class 10, single stage with flowmeter, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 1,5 bar fixed<br />flow: 2,0 - 23,0 Nl/min. forming gas adjustable<br />Inlet connection: W 21,8x1/14 LH nut acc. to DIN 477-1, no. 1<br />outlet connection: G 3/8 LHk x 9mm tailpiece EN 560<br />inlet gauge: 0 – 315/200 bar<br />width x height x depth: 210 x 230 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3476 |
|
<p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171, with shut off valve,inlet pressure max: 200 bar</p><p>outlet pressure: 0 – 10 bar adjustable<br><br>flow max: 48 Nm³/h at 10 bar outlet pressure <br><br>inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br><br>outlet connection: G 1/4RH x 6mm tail-piece<br><br>inlet gauge: 0 – 315/200 bar<br><br>working gauge: 0 – 16/10 bar<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3477 |
|
acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0-10 bar<br />flow: 0 – 20 Nl/min. adjustable<br />Inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 – 315/200 bar<br />outlet gauge: 0 – 20 Nl/min. double scale Ar/CO2 (0 - 10 bar)<br />width x height x depth: 210 x 230 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3478 |
|
acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171, with shut off valve,inlet pressure max: 200 bar<br />outlet pressure: 0 – 10 bar <br />flow: 0 – 30 Nl/min. adjustable<br />inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 30 Nl/min. (0 - 10 bar)<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde tape |
|
|
|
|
|
| 3479 |
|
acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0-10 bar<br />flow: 0 – 20 Nl/min. adjustable<br />Inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 – 315/200 bar<br />outlet gauge: 0 – 30 Nl/min. double scale Ar/CO2 (0 - 10 bar)<br />width x height x depth: 210 x 230 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3480 |
|
<p>acc to DIN EN ISO 2503,class 3, double stage, with safety gauges acc. to DIN ISO 5171</p><p>inlet pressure max: 200 bar<br><br>outlet pressure: 0 – 10 bar adjustable<br><br>flow max: 28 Nm³/h air at 10 bar outlet pressure <br><br>inlet: W21,8x1/14RH nut acc. to DIN 477-1, no. 6<br><br>outlet: G 1/4 RHk male with 6mm tail-piece,<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 16/10 bar<br><br>width x height x depth: 240 x 190 x 75 mm</p> |
|
|
|
|
|
| 3481 |
|
<p>acc to DIN EN ISO 2503, class 10, single stage with flowmeter, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar</p><p>outlet pressure: 1,5 bar fixed<br><br>flow: 1,0 – 14,0 Nl/min. argon adjustable<br><br>Inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br><br>outlet connection: G 1/4 RHk x 6mm tailpiece EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth: 210 x 230 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3482 |
|
<p>acc to ISO 2503, class 20, single stage, with flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 200 bar</p><p>outlet pressure: 2,5 bar pre adjusted<br><br>flow: 1,0 – 30 Nl/min. adjustable<br><br>inlet: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6,<br><br>outlet: G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth:: 210 x 230 x 75 mm<br><br>With Linde-Logo stamped on body, with Linde operating manual and Linde tape<br><br><br><br>replaces article 22645589!</p> |
|
|
|
|
|
| 3483 |
|
acc to DIN EN ISO 2503, class 20, single stage with flowmeter, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauge acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 2,5 bar fixed<br />flow: 3-30 Nl/min. Mison adjustable<br />Inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4 RHk x 6mm tailpiece EN 560<br />inlet gauge: 0 – 315/200 bar<br />width x height x depth: 210 x 230 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3488 |
|
according to ISO 2503, class 3,single stage with high-pressure compensation, with safety gauges according to ISO 5171, including shut off valveinlet pressure max.: 300 bar<br />working pressure: 0 - 10 bar adjustable <br />flow max. 48 Nm³/h compressed air at 10 bar working pressure<br />inlet connection: W 30x2 RH acc. to DIN 477-5, no. 54<br />outlet connection: G 1/4 RH x 6 mm acc. to EN 560<br />cylinder gauge 0 - 400/300 bar<br />working gauge: 0 - 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3489 |
|
acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:300 bar<br />outlet pressure: 10 - 100 bar adjustable<br />flow max:380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 24,32x1/14 RH male DIN 477-1, no. 10<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 160/100 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3490 |
|
acc. to ISO 2503, single stage with safety gauges acc. to ISO5171inlet pressure max: 300 bar<br />outlet pressure: 10 - 300 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 24,32x1/14 RH male DIN 477-1, no. 10<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3491 |
|
acc. to ISO 2503, class3, with high pressure compensation, single stage with safety gauges acc. to DIN ISO 5171inlet pressure max:300 bar<br />outlet pressure: 0 – 10 bar adjustable<br />flow max: 48 Nm³/h at 10 bar outlet pressure<br />inlet connection: W 30x2LHk nut acc. to DIN 477-5, Nr. 57<br />outlet connection: G 3/8 LHk x 9mm tail-piece acc. to DIN EN 560<br />inlet gauge: 0 – 400 / 300 bar<br />working gauge: 0 – 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3492 |
|
acc. to ISO 2503, class 5, single stage, with high pressure compensation for constant working pressure, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 300 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max.: 75 Nm³/h air at 10 bar working pressure<br />Inlet connection: W30x2LH nut acc. to DIN 477-5 no. 57<br />outlet connection: G 3/8 LHk x 9 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 400/300 bar<br />working gauge: 0 - 40/20 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3493 |
|
<p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,</p><p>with shut off valve<br><br>inlet pressure max: 200 bar<br><br>outlet pressure: 0 - 50 Nl/min. (0 – 10 bar) adjustable<br><br>flow max: 50 Nl/min. at 10 bar outlet pressure <br><br>inlet connection: W 30x2 LH nut acc. to DIN 477-5 no. 57<br><br>outlet connection: G 3/8 LHk x 9 mm tail-piece acc. EN560<br><br>inlet gauge: 0 – 400/300 bar<br><br>working gauge: 0 – 50 Nl/min.<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3494 |
|
<p>acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar</p><p>outlet pressure: 0 – 60 bar adjustable<br><br>flow max: 140 Nm³/h at 60 bar working pressure<br><br>inlet connection: W30x2 RHf nut acc. to DIN 477-5, no. 54<br><br>outlet connection: G 1/4RHak acc. to EN560<br><br>inlet gauge: 0 – 400/300 bar<br><br>working gauge: 0 – 100/60 bar<br><br>width x height x depth: 210 x 210 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3495 |
|
acc. to ISO 2503, single stage with safety gauges acc. to ISO 5171inlet pressure max:300 bar<br />outlet pressure: 10 - 100 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 21,8x1/14 RH male DIN 477-1, no. 6<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 160/100 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3496 |
|
acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max: 300 bar<br />outlet pressure: 10 - 300 bar adjustable<br />flow max:380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 21,8x1/14 RH male DIN 477-1, no. 6<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3497 |
|
according to ISO 2503, class 3, adiabatic compression tested, single stage with high-pressure compensation, with safety gauges according to ISO 5171, including shut off valveinlet pressure max.: 300 bar<br />working pressure: 0 - 10 bar adjustable <br />flow max. 48 Nm³/h compressed air at 10 bar working pressure<br />inlet connection: W 30x2 RH acc. to DIN 477-5, no. 59<br />outlet connection: G 1/4 RH x 6 mm acc. to EN 560<br />cylinder gauge 0 - 400/300 bar<br />working gauge: 0 - 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3498 |
|
acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:300 bar<br />outlet pressure: 10 - 100 bar adjustable<br />flow max:380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 59<br />outlet connection: G3/4RHf male DIN 477-1, no. 9<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 160/100 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3499 |
|
According to DIN EN ISO 7291, single-stage design, with safety pressure gaugesDIN ISO 5171, chrome-plated lifter, hard PVC locking cone, with metal membrane,<br />Inlet pressure max: 300 bar<br />Output pressure: 0 – 10 bar adjustable<br />Output max: 90 Nm³/h compressed air at 10 bar back pressure<br />Input (rear): M 24x1.5 RHk - S16 Ü-nut<br />Output: G3/4RH x 18mm solder socket<br />Input pressure gauge: 0 – 400/300 bar<br />Output pressure gauge: 0 – 16/10 bar<br />Blow-off valve with mounted Cu pipe bend (270°, 10x1 mm)<br />Width x Height x Depth: 160 x 326 x 108 mm<br />With manufacturer's declaration, operating instructions, shrink-wrapped in food-safe foil with sticker with Linde number/oil and fat-free on cardboard, individually packed in foamed cardboard, with Linde adhesive tape, "glass fork symbol" (according to Regulation (EC) 1935/2004, Annex II) on foil and cardboard, code letter "N".<br />The pressure reducer meets the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and the LFGB and is suitable for contact with food gases.<br />Factory certificate 2.2 and test report<br />With sticker, nameplate and warning “not for oxygen” |
|
|
|
|
|
| 3500 |
|
<p>free of oil- and grease, for oxygen, acc. to ISO 7291 with metal diaphragm, single stage, adiabatic compression tested acc. to ISO 7291, with safety gauges acc. to ISO 5171inlet pressure max: 300 bar</p><p>outlet pressure: 0 – 40 bar adjustable<br><br>flow max: 125 Nm³/h compr. air at 40 bar outlet pressure <br><br>inlet (on the back): M 24x1,5 RHk - S16 nut<br><br>outlet: G3/4RH x 18mm brazing connection<br><br>inlet gauge: 0 – 400/300 bar<br><br>working gauge: 0 – 60/40 bar<br><br>width x height x depth: 170 x 200 x 106 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
|
| 3501 |
|
free of oil- and grease, for oxygen, acc. to ISO 7291 with metal diaphragm, single stage, adiabatic compression tested acc. to ISO7291, with safety gauges acc. to ISO 5171inlet pressure max: 300 bar<br />outlet pressure: 15 – 40 bar adjustable<br />flow max: 250 Nm³/h compr. air at 40 bar outlet pressure <br />inlet (on the back): M 24x1,5 RHk - S16 nut<br />outlet: G3/4RH x 18mm brazing connection<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 60/40 bar<br />width x height x depth: 200 x 330 x 110 mm<br />With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br />The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br />Test report and test report 2.2 |
|
|
|
|
|
| 3502 |
|
<p>acc to ISO2503, single stage, with flowmeter for exact control of the flow in Nl/min, TÜV – approved following Pressure equipment Directive 97/23/EG with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 300 bar</p><p>outlet pressure: 1,5 bar pre adjusted<br><br>flow: 2 – 23 Nl/min. adjustable<br><br>inlet: W 30x2 LH nut acc. to DIN 477-5<br><br>outlet: G 3/8 LHk x 9 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 400/300 bar<br><br>width x height x depth:: 210 x 230 x 75 mm</p> |
|
|
|
|
|
| 3503 |
|
acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171, with shut off valve,inlet pressure max: 300 bar<br />outlet pressure: 0 – 10 bar <br />flow: 0 – 30 Nl/min. adjustable<br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 30 Nl/min. (0 - 10 bar)<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde tape |
|
|
|
|
|
| 3913 |
|
<p>oxygen 300 baracc. to DIN 477-5 No. 595-pack #911025 in PE-foil bag</p><p>incl. test report 2.2</p> |
|
|
|
|
|
| 3914 |
|
<p>inert gases and fuel gases 300 baracc. to DIN 477- 5, No. 54, 56 und 575-pack #911028 in PE-foil bag</p><p>incl. test report 2.2</p> |
|
|
|
|
|
| 3933 |
|
<p>In-line dome pressure reducer Vulkan LD1 MD on both sides. G 1 RHi, single-stage design, without pressure gauge. Maximum inlet pressure: 100 bar (oxygen max. 40 bar!). Output pressure: 0.5 - 99 bar adjustable (oxygen 0.5 - 39 bar!). Maximum output: 2,400 Nm³/h (oxygen 2,100 Nm³/h). Inlet and outlet: G1RHi. Width x height x depth: 130 x 170 x 130 mm. Optionally also available with control pressure reducer. Available for various gas types (please select in the selection window!): Oxygen: Item No. 108535 (pe max. 40 bar pa 0.5 - 39 bar!). CO2/Argon: Item No. 106535. Helium: Item No. 10653526Nitrogen: Item no. 103535Hydrogen: Item no. 104535Compressed air: Item no. 107535</p> |
|
|
|
|
|
| 3934 |
|
<p>In-line dome pressure reducer Vulkan LD1 MD on both sides. G 1 RHi, single-stage design, without pressure gauge. Maximum inlet pressure: 100 bar (oxygen max. 40 bar!). Output pressure: 0.5 - 99 bar adjustable (oxygen 0.5 - 39 bar!). Maximum output: 2,400 Nm³/h (oxygen 2,100 Nm³/h). Inlet and outlet: G1RHi. Width x height x depth: 130 x 170 x 130 mm. Optionally also available with control pressure reducer. Available for various gas types (please select in the selection window!): Oxygen: Item No. 108535 (pe max. 40 bar pa 0.5 - 39 bar!). CO2/Argon: Item No. 106535. Helium: Item No. 10653526Nitrogen: Item no. 103535Hydrogen: Item no. 104535Compressed air: Item no. 107535</p> |
|
|
|
|
|
| 3935 |
|
<p>In-line dome pressure reducer Vulkan LD1 MD on both sides. G 1 RHi, single-stage design, without pressure gauge. Maximum inlet pressure: 100 bar (oxygen max. 40 bar!). Output pressure: 0.5 - 99 bar adjustable (oxygen 0.5 - 39 bar!). Maximum output: 2,400 Nm³/h (oxygen 2,100 Nm³/h). Inlet and outlet: G1RHi. Width x height x depth: 130 x 170 x 130 mm. Optionally also available with control pressure reducer. Available for various gas types (please select in the selection window!): Oxygen: Item No. 108535 (pe max. 40 bar pa 0.5 - 39 bar!). CO2/Argon: Item No. 106535. Helium: Item No. 10653526Nitrogen: Item no. 103535Hydrogen: Item no. 104535Compressed air: Item no. 107535</p> |
|
|
|
|
|
| 6948 |
|
free of oil- and grease, acc. to ISO 7291, with metal diaphragm, single stage, with safety gauges acc. to ISO 5171inlet pressure max: 100 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max: 75 Nm³/h compr. air at 20 bar outlet pressure <br />inlet: (rear): M 24x1,5 RHk - S16 nut<br />outlet: G3/4RH x 18mm brazing piece<br />relief valve with mounted copper pipe bend (270 °, 10x1 mm)<br />inlet gauge: 0 – 160/100 bar<br />working gauge: 0 – 40/20 bar<br />width x height x depth: 170 x 200 x 106 mm<br />With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "N", additional sticker on foil: "No cost-free redemption when foil is damaged "<br />The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br />Test report and test report 2.2<br />with sticker "not for oxygen use"<br /><br />Due to the cooling energy evolving from the decompression, the output of the regulator is strongly limited and does not comply with the above mentioned value indicated for the use of compressed air.<br />For continously high flow the additional use of a gas pre heater may be necessary. |
|
|
|
|
|
| 6949 |
|
<p>acc to DIN EN ISO 2503, class 10, single stage, with double flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 200 bar</p><p>outlet pressure: 1,5 bar pre adjusted<br><br>flow: 2 x 2-23 Nl/min. adjustable<br><br>inlet: W 24,32x1/14 RH nut acc. to DIN 477-1, no. 1<br><br>outlet: 2x G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth: 250 x 230 x 130 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 6950 |
|
acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:200 bar<br />outlet pressure: 10 - 200 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 24,32x1/14 RH nut acc. to DIN 477-1, no. 10<br />outlet connection: W24,32x1/14RH male acc. to DIN 477-1, no. 10<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 6951 |
|
acc to EN 13918, class 10, single stage, with flowmeter for exact control of the flow in Nl/min, TÜV – approved following Pressure equipment Directive 97/23/EG with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 300 bar<br />outlet pressure: 1,5 bar pre adjusted<br />flow: 4 – 32 Nl/min. adjustable<br />inlet: W 30x2 RH nut acc. to DIN 477-5<br />outlet: G 1/4 RHk x 6 mm tail-piece acc. EN 560<br />inlet gauge: 0 – 400/300 bar<br />width x height x depth:: 210 x 230 x 75 mm |
|
|
|
|
|
| 6954 |
|
<p>free of oil- and grease, for inert gas, fuel gas and oxygen, consisting of:</p><p>1 distribution block with an input with sintered filter, non-return valve and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate,<br><br>inlet pressure max: 300 bar<br><br>input (bottom): M 20x1, 5 RHak-12S for operating of cylinder<br><br>outlet (left): M 20x1, 5 RHk-12S nut to connect to a manifold<br><br>outlet (right): M 20x1, 5 RHak-12S to connect to further manifold module <br><br>Width x height x depth: 315x 167 x 110 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
|
| 6955 |
|
<p>free of oil- and grease, for inert gas, fuel gas and oxygen, consisting of:</p><p>1 distribution block with an input with sintered filter, non-return valve and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate,<br><br>inlet pressure max: 300 bar<br><br>input (bottom): M 20x1, 5 RHak-12S for operating of cylinder<br><br>outlet (right): M 20x1, 5 RHk-12S nut to connect to a manifold<br><br>outlet (left): M 20x1, 5 RHak-12S to connect to further manifold module <br><br>Width x height x depth: 315x 167 x 110 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
|
| 6956 |
|
<p>free of oil- and grease, for inert gas, fuel gas and oxygen, consisting of:</p><p>1 distribution block with an input with sintered filter, non-return valve and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate,<br><br>inlet pressure max: 300 bar<br><br>input (bottom): M 20x1, 5 RHak-12S for operating of cylinder<br><br>outlet (right): M 20x1, 5 RHk-12S nut to connect to a manifold<br><br>outlet (left): M 20x1, 5 RHak-12S to connect to further manifold module <br><br>Width x height x depth: 915x 167 x 110 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
|
| 6957 |
|
<p>free of oil- and grease, for inert gas, fuel gas and oxygen, consisting of:</p><p>1 distribution block with an input with sintered filter, non-return valve and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate,<br><br>inlet pressure max: 300 bar<br><br>input (bottom): M 20x1, 5 RHak-12S for operating of cylinder<br><br>outlet (right): M 20x1, 5 RHk-12S nut to connect to a manifold<br><br>outlet (left): M 20x1, 5 RHak-12S to connect to further manifold module <br><br>Width x height x depth: 915 x 167 x 110 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
|