Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
| 12956 |
|
Single-bundle acetylene manifold station Vulkan TecLine EB10 (with standard gauges). Complete on stainless steel base plate, acc. to ISO 14114, with HA10 regulator acc. to ISO 7291, automatic quick cut-off valve acc. to ISO 15615, flashback arrestor acc. to ISO 5175, and main shut-off valve. Manual switching. Inlet pressure max 26 bar, outlet pressure 0–1.5 bar. Max. flow 10 Nm³/h at 1.5 bar. Dimensions: 700 × 190 × 160 mm, 14 kg. |
|
|
|
|
| 12958 |
|
Single-bundle acetylene manifold station Vulkan TecLine EB20 (with standard gauges). Complete on stainless steel base plate, acc. to ISO 14114, with HA10/H20 regulator acc. to ISO 7291, automatic quick cut-off valve acc. to ISO 15615, flashback arrestor acc. to ISO 5175, and main shut-off valve. Manual switching. Inlet pressure max 26 bar, outlet pressure 0–1.5 bar. Max. flow 18 Nm³/h at 1.5 bar. Dimensions: 970 × 190 × 160 mm, 16 kg. |
|
|
|
|
| 13028 |
|
Single-bundle manifold station Vulkan TecLine EB120/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator HR60 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 15–60 bar. Max. flow 450 Nm³/h at 60 bar. With standard pressure gauges. Dimensions: N/A mm, N/A kg. |
|
|
|
|
| 13040 |
|
Single-bundle manifold station Vulkan TecLine EB200/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator HR200 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 15–200 bar. Max. flow 480 Nm³/h at 200 bar. With standard pressure gauges. Dimensions: 390 × 240 × 240 mm, N/A kg. |
|
|
|
|
| 13052 |
|
Single-bundle manifold station Vulkan TecLine EB270/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator HR270 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 15–270 bar. Max. flow 480 Nm³/h at 270 bar. With standard pressure gauges. Dimensions: 390 × 240 × 240 mm, N/A kg. |
|
|
|
|
| 13085 |
|
Manual manifold base station Vulkan TecLine BS 75/300 Effect. Modular add-on system (Modula Vareo). Complete on stainless steel base plate: 1× distributing block Modula Vareo (2 inlets, shut-off valves, non-return valves, sinter-metal filters), 1× manifold fin regulator HR60 Effect acc. to ISO 7291 (adiabatic compression tested), 1× main shut-off valve. Manual switching. Inlet max 300 bar, outlet 0–60 bar. Max. flow 140 Nm³/h at 60 bar. Dimensions: 570 × 250 × 210 mm, 10 kg. |
|
|
|
|