Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
unit_name |
| 6949 |
|
<p>acc to DIN EN ISO 2503, class 10, single stage, with double flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 200 bar</p><p>outlet pressure: 1,5 bar pre adjusted<br><br>flow: 2 x 2-23 Nl/min. adjustable<br><br>inlet: W 24,32x1/14 RH nut acc. to DIN 477-1, no. 1<br><br>outlet: 2x G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth: 250 x 230 x 130 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 13098 |
|
Manual manifold base station Vulkan TecLine BS 100/300 Effect. Modular add-on system (Modula Vareo). Complete on stainless steel base plate: 1× distributing block Modula Vareo (2 inlets, shut-off valves, non-return valves, sinter-metal filters), 1× manifold fin regulator HR40 Effect acc. to ISO 7291 (adiabatic compression tested), 1× main shut-off valve. Manual switching. Inlet max 300 bar, outlet 15–40 bar. Max. flow 290 Nm³/h at 40 bar. Dimensions: 590 × 270 × 210 mm, 14 kg. |
|
|
|
|
|
| 13105 |
|
Manual manifold base station Vulkan TecLine BS 120/300 Effect. Modular add-on system (Modula Vareo). Complete on stainless steel base plate: 1× distributing block Modula Vareo (2 inlets, shut-off valves, non-return valves, sinter-metal filters), 1× manifold fin regulator HR60 Effect acc. to ISO 7291 (adiabatic compression tested), 1× main shut-off valve. Manual switching. Inlet max 300 bar, outlet 15–60 bar. Max. flow 450 Nm³/h at 60 bar. Dimensions: 590 × 270 × 210 mm, 14 kg. |
|
|
|
|
|
| 13112 |
|
Manual manifold base station Vulkan TecLine BS 200/300. Modular add-on system (Modula Vareo). Complete on stainless steel base plate: 1× distributing block Modula Vareo (2 inlets, shut-off valves, non-return valves, sinter-metal filters), 1× manifold manifold regulator LHR 300/200 acc. to ISO 7291 (adiabatic compression tested), 1× main shut-off valve. Manual switching. Inlet max 300 bar, outlet 15–200 bar. Max. flow 480 Nm³/h at 200 bar. Dimensions: 590 × 330 × 285 mm, 12 kg. |
|
|
|
|
|
| 13118 |
|
Manual manifold base station Vulkan TecLine BS 270/300. Modular add-on system (Modula Vareo). Complete on stainless steel base plate: 1× distributing block Modula Vareo (2 inlets, shut-off valves, non-return valves, sinter-metal filters), 1× manifold manifold regulator acc. to ISO 7291 (adiabatic compression tested), 1× main shut-off valve. Manual switching. Inlet max 300 bar, outlet 15–270 bar. Max. flow 480 Nm³/h at 270 bar. Dimensions: 590 × 330 × 285 mm, 12 kg. |
|
|
|
|
|
| 13124 |
|
Manual manifold base station for acetylene bundles Vulkan TecLine BSA 10 B. Complete on stainless steel base plate acc. to ISO 14114: 1× distributing block Modula Vareo with automatic quick cut-off valve acc. to ISO 15615, 1× flashback arrestor acc. to ISO 5175, 1× manifold fin regulator HA10 acc. to ISO 7291, 1× main shut-off valve. Manual switching. Inlet max 26 bar, outlet 0–1.5 bar. Max. flow 10 Nm³/h. Dimensions: 850 × 250 × 210 mm, 15 kg. |
|
|
|
|
|
| 13125 |
|
Manual manifold base station for acetylene bundles Vulkan TecLine BSA 20 B. Complete on stainless steel base plate acc. to ISO 14114: 1× distributing block Modula Vareo with automatic quick cut-off valve acc. to ISO 15615, 1× flashback arrestor acc. to ISO 5175, 1× manifold regulator H20 acetylene acc. to ISO 7291, 1× main shut-off valve. Manual switching. Inlet max 26 bar, outlet 0–1.5 bar. Max. flow 18 Nm³/h. Dimensions: 980 × 250 × 230 mm, 19 kg. |
|
|
|
|
|
| 13126 |
|
Manual manifold base station for acetylene bundles Vulkan TecLine BSA 40 B. Complete on stainless steel base plate acc. to ISO 14114: 1× distributing block Modula Vareo with automatic quick cut-off valve acc. to ISO 15615, 1× flashback arrestor acc. to ISO 5175, 1× manifold fin regulator HA40 acc. to ISO 7291, 1× main shut-off valve. Manual switching. Inlet max 26 bar, outlet 0–1.5 bar. Max. flow 38 Nm³/h. Dimensions: 980 × 275 × 210 mm, 26 kg. |
|
|
|
|
|
| 13298 |
|
Manifold station Modula Vareo VS for oxygen, inert and fuel gases (except acetylene). Vareo distribution block with 2 inlets M 24×1.5 RH for connecting 2 cylinders or bundles up to 300 bar. Equipped with 2 sinter filters, 2 non-return valves (NRV), 2 shut-off valves, and 2 connections for additional manifold stations or base station Vareo. Fully assembled on base plate. Material: brass. Dimensions: 195 × 205 × 240 mm. |
|
|
|
|
|
| 13299 |
|
Manifold station Modula Vareo VS for acetylene. Vareo distribution block with 2 inlets W 21.8×1/14 LH for connecting 2 cylinders or bundles up to 300 bar. Equipped with 2 sinter filters, 2 non-return valves (NRV), 2 shut-off valves, and 2 connections for additional manifold stations or base station Vareo. Fully assembled on base plate. Material: brass. Dimensions: 195 × 205 × 240 mm. |
|
|
|
|
|
| 13300 |
|
Manifold station Modula Vareo VSD for oxygen, inert and fuel gases (except acetylene). Without non-return valve and sinter filter. Vareo distribution block with 2 inlets M 24×1.5 RH for connecting 2 cylinders or bundles up to 300 bar. 2 shut-off valves and 2 connections for additional manifold stations or base station Vareo. Fully assembled on base plate. Material: brass. Dimensions: 195 × 205 × 240 mm. |
|
|
|
|
|
| 13301 |
|
Manifold station Modula Vareo VSL for oxygen, inert and fuel gases (except acetylene). Without shut-off valve. Vareo distribution block with 2 inlets M 24×1.5 RH for connecting 2 cylinders or bundles up to 300 bar. 2 sinter filters, 2 non-return valves and 2 connections for additional manifold stations or base station Vareo. Fully assembled on base plate. Material: brass. Dimensions: 195 × 205 × 240 mm. |
|
|
|
|
|