SELECT 
  cscart_product_descriptions.product_id, 
  cscart_product_descriptions.short_description, 
  IF(
    cscart_product_descriptions.short_description = '' 
    OR cscart_product_descriptions.short_description IS NULL, 
    cscart_product_descriptions.full_description, 
    ''
  ) AS full_description, 
  cscart_product_descriptions.meta_keywords, 
  cscart_product_descriptions.meta_description, 
  cscart_product_descriptions.search_words, 
  cscart_product_descriptions.promo_text, 
  cscart_product_descriptions.unit_name 
FROM 
  cscart_product_descriptions 
WHERE 
  cscart_product_descriptions.product_id IN (
    13176, 13162, 13169, 13232, 13225, 13190, 
    13183, 13239, 13204, 13197, 13246, 
    13218, 13211, 13253, 13302, 13303, 
    13308, 13309, 13306, 13307, 13310, 
    13311, 13312, 13313, 13304, 13305, 
    13319, 6962, 6966, 6967, 6965, 6963, 
    6952, 6953, 6947, 6959, 3425, 6958, 
    6960, 6968, 6961, 6964, 6957, 6956, 
    6954, 6955, 6948, 6950, 6949, 13298, 
    13299, 13300, 13301, 13124, 13125, 
    13126, 13098, 13105, 13112, 13118, 
    13064, 13071, 13078, 13085, 13091, 
    13314, 13316, 13315, 13317, 13318, 
    12956, 12958, 13014, 13028, 13040, 
    13052, 12960, 12974, 12988, 13000, 
    12926, 12942
  ) 
  AND cscart_product_descriptions.lang_code = 'en'

Query time 0.00180

JSON explain

{
  "query_block": {
    "select_id": 1,
    "cost_info": {
      "query_cost": "82.84"
    },
    "table": {
      "table_name": "cscart_product_descriptions",
      "access_type": "range",
      "possible_keys": [
        "PRIMARY",
        "product_id"
      ],
      "key": "PRIMARY",
      "used_key_parts": [
        "product_id",
        "lang_code"
      ],
      "key_length": "9",
      "rows_examined_per_scan": 82,
      "rows_produced_per_join": 82,
      "filtered": "100.00",
      "index_condition": "((`test2_gaseus`.`cscart_product_descriptions`.`product_id` in (13176,13162,13169,13232,13225,13190,13183,13239,13204,13197,13246,13218,13211,13253,13302,13303,13308,13309,13306,13307,13310,13311,13312,13313,13304,13305,13319,6962,6966,6967,6965,6963,6952,6953,6947,6959,3425,6958,6960,6968,6961,6964,6957,6956,6954,6955,6948,6950,6949,13298,13299,13300,13301,13124,13125,13126,13098,13105,13112,13118,13064,13071,13078,13085,13091,13314,13316,13315,13317,13318,12956,12958,13014,13028,13040,13052,12960,12974,12988,13000,12926,12942)) and (`test2_gaseus`.`cscart_product_descriptions`.`lang_code` = 'en'))",
      "cost_info": {
        "read_cost": "74.64",
        "eval_cost": "8.20",
        "prefix_cost": "82.84",
        "data_read_per_join": "374K"
      },
      "used_columns": [
        "product_id",
        "lang_code",
        "short_description",
        "full_description",
        "meta_keywords",
        "meta_description",
        "search_words",
        "promo_text",
        "unit_name"
      ]
    }
  }
}

Result

product_id short_description full_description meta_keywords meta_description search_words promo_text unit_name
3425 <p>free of oil- and grease, for inert gas, fuel gas and oxygen, BAM - approved,consisting of: 2 HP double shut-off valve, 2 pressure regulator HR 20 acc. to ISO 7291, BAM - approved with membrabe and HP-contact gauges with inductive-contact, in Ruhestellung geöffnet, bei steigendem Druck schließend, incl. 2 Meter langem, 2 pol. Anschlußkabel, Farbe "blau", Abblaseventile mit montiertem Cu-Rohrbogen (270°, 10x1 mm), 1 change over block and 2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p><p>inlet pressure max: 300 bar<br><br>outlet pressure: 20 bar fixed<br><br>flow max: 170 Nm³/h air at 20 bar outle tpressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 40/20 bar<br><br>width x height x depth: 875 x 325 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p>
6947 flexible Metall hose with two anti kink springs and anti whip cable assembled complete mounted on hose, length: 1.000 mminlet W21,8x1/14RHf nut acc. to DIN 477-1, No. 6, with 90° angle<br />outlet M20x1,5RHk nut - 12S
6948 free of oil- and grease, acc. to ISO 7291, with metal diaphragm, single stage, with safety gauges acc. to ISO 5171inlet pressure max: 100 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max: 75 Nm³/h compr. air at 20 bar outlet pressure <br />inlet: (rear): M 24x1,5 RHk - S16 nut<br />outlet: G3/4RH x 18mm brazing piece<br />relief valve with mounted copper pipe bend (270 °, 10x1 mm)<br />inlet gauge: 0 – 160/100 bar<br />working gauge: 0 – 40/20 bar<br />width x height x depth: 170 x 200 x 106 mm<br />With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "N", additional sticker on foil: "No cost-free redemption when foil is damaged "<br />The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br />Test report and test report 2.2<br />with sticker "not for oxygen use"<br /><br />Due to the cooling energy evolving from the decompression, the output of the regulator is strongly limited and does not comply with the above mentioned value indicated for the use of compressed air.<br />For continously high flow the additional use of a gas pre heater may be necessary.
6949 <p>acc to DIN EN ISO 2503, class 10, single stage, with double flowmeter for exact control of the flow in Nl/min, with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 200 bar</p><p>outlet pressure: 1,5 bar pre adjusted<br><br>flow: 2 x 2-23 Nl/min. adjustable<br><br>inlet: W 24,32x1/14 RH nut acc. to DIN 477-1, no. 1<br><br>outlet: 2x G 1/4 RHk x 6 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 315/200 bar<br><br>width x height x depth: 250 x 230 x 130 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p>
6950 acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:200 bar<br />outlet pressure: 10 - 200 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 24,32x1/14 RH nut acc. to DIN 477-1, no. 10<br />outlet connection: W24,32x1/14RH male acc. to DIN 477-1, no. 10<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
6952 <p>free of oil- and grease, for inert gas, fuel gas and oxygen, adiabatic compression tested,consisting of: HP double shut-off valve, with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p><p>inlet: M 20x1,5 RHak -12S usuage for 1 cylinder or bundles<br><br>outlet: M 24 x 1.5 RHak - 16S to connect a main pressure regulator<br><br>width x height x depth: 370 x 205 x 160 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", <br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p>
6953 <p>free of oil- and grease, for inert gas, fuel gas and oxygen, adiabatic compression tested,consisting of:</p><p>1 HP double shut-off valve, <br><br>2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate,<br><br>inlet pressure max: 300 bar<br><br>inlets (bottom): 2 x M 20x1, 5 RHak-12S for operating 2 x 1 cylinder or bundle<br><br>outlet: M 24 x 1.5 RHak - 16S to connect a main pressure regulator<br><br>width x height x depth: 370 x 205 x 160 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", <br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p>
6954 <p>free of oil- and grease, for inert gas, fuel gas and oxygen, consisting of:</p><p>1 distribution block with an input with sintered filter, non-return valve and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate,<br><br>inlet pressure max: 300 bar<br><br>input (bottom): M 20x1, 5 RHak-12S for operating of cylinder<br><br>outlet (left): M 20x1, 5 RHk-12S nut to connect to a manifold<br><br>outlet (right): M 20x1, 5 RHak-12S to connect to further manifold module <br><br>Width x height x depth: 315x 167 x 110 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p>
6955 <p>free of oil- and grease, for inert gas, fuel gas and oxygen, consisting of:</p><p>1 distribution block with an input with sintered filter, non-return valve and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate,<br><br>inlet pressure max: 300 bar<br><br>input (bottom): M 20x1, 5 RHak-12S for operating of cylinder<br><br>outlet (right): M 20x1, 5 RHk-12S nut to connect to a manifold<br><br>outlet (left): M 20x1, 5 RHak-12S to connect to further manifold module <br><br>Width x height x depth: 315x 167 x 110 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p>
6956 <p>free of oil- and grease, for inert gas, fuel gas and oxygen, consisting of:</p><p>1 distribution block with an input with sintered filter, non-return valve and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate,<br><br>inlet pressure max: 300 bar<br><br>input (bottom): M 20x1, 5 RHak-12S for operating of cylinder<br><br>outlet (right): M 20x1, 5 RHk-12S nut to connect to a manifold<br><br>outlet (left): M 20x1, 5 RHak-12S to connect to further manifold module <br><br>Width x height x depth: 915x 167 x 110 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p>
6957 <p>free of oil- and grease, for inert gas, fuel gas and oxygen, consisting of:</p><p>1 distribution block with an input with sintered filter, non-return valve and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate,<br><br>inlet pressure max: 300 bar<br><br>input (bottom): M 20x1, 5 RHak-12S for operating of cylinder<br><br>outlet (right): M 20x1, 5 RHk-12S nut to connect to a manifold<br><br>outlet (left): M 20x1, 5 RHak-12S to connect to further manifold module <br><br>Width x height x depth: 915 x 167 x 110 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p>
6958 <p>free of oil- and grease, for oxygen, consisting of: 2 HP shut-off valve, 2 pressure regulator H 40 acc. to ISO 7291, adiabatic compression tested acc. to ISO7291, with metal diaphragm and HP-contact gauges with inductive-contact, 2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p><p>inlet pressure max: 300 bar<br><br>outlet pressure: 28 bar fixed<br><br>flow max: 125 Nm³/h air at 28 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 60/40 bar<br><br>width x height x depth: 875 x 325 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p>
6959 <p>free of oil- and grease, for oxygen,consisting of: 2 HP shut-off valve, 2 pressure regulator H20 acc to ISO 7291, single stage, adiabatic compression tested acc. to ISO7291, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 1 change over block and 2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p><p>inlet pressure max: 300 bar<br><br>outlet pressure: 15 bar fixed<br><br>flow max: 75 Nm³/h air at 15 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 40/20 bar<br><br>width x height x depth: 875 x 325 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p>
6960 <p>free of oil- and grease, for oxygen, consisting of: 2 HP shut-off valve, 2 pressure regulator HR 40 acc. to ISO 7291, adiabatic compression tested acc. to ISO7291, with metal diaphragm and HP-contact gauges with inductive-contact, 2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p><p>inlet pressure max: 300 bar<br><br>outlet pressure: 28 bar fixed<br><br>flow max: 250 Nm³/h air at 28 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 60/40 bar<br><br>width x height x depth: 875 x 325 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p>
6961 <p>free of oil- and grease, for hydrogen an forming gas,consisting of: 2 HP shut-off valve, 2 pressure regulator H40 acc to ISO 7291, single stage, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 2 solenoid valves 230VAC, 1 double non return valve and 2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p> <p>inlet pressure max: 300 bar<br><br>outlet pressure: 25 bar fixed<br><br>flow max: 125 Nm³/h air at 40 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 60/40 bar<br><br>width x height x depth: 1.095 x 325 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "H", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2<br><br>With note labeld: "not for oxygen use"</p>
6962 <p>free of oil- and grease, for hydrogen and forming gas, consisting of: 2 HP shut-off valve, 2 pressure regulator H20 acc to ISO 7291, single stage, with metal diaphragm and HP-contact gauges with inductive-contact (NO), electric cable blue, length 2.000mm</p> <p>2 solenoid valves 230VAC, <br><br>1 double non return valve and <br><br>2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate<br><br>inlet pressure max: 300 bar<br><br>outlet pressure: 15 bar fixed<br><br>flow max: 75 Nm³/h air at 15 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 40/20 bar<br><br>width x height x depth: 1095 x 300 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "H", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2<br><br>with warning note:"not to use with oxygen"</p>
6963 <p>free of oil- and grease, for nitrogen and compressed air,consisting of: 2 HP shut-off valve, 2 pressure regulator H40 acc. to ISO 7291, single stage, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 2 solenoid valves 230VAC, 1 double non return valve and 2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p><p>inlet pressure max: 300 bar<br><br>outlet pressure: 40 bar fixed<br><br>flow max: 125 Nm³/h air at 40 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 60/40 bar<br><br>width x height x depth: 1.095 x 325 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "N", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2<br><br>With sticker "Not for oxygen use"</p>
6964 <p>free of oil- and grease, for nitrogen, compressed air and helium use, consisting of: 2 HP shut-off valve, 2 pressure regulator HR40 acc to ISO 7291, single stage, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 2 solenoid valves 230VAC, 1 double non return valve and 2 distribution blocks, each with an input with sintered filter, non-return valve, connection for a safety valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p> <p>inlet pressure max: 300 bar<br><br>outlet pressure: 40 bar fixed<br><br>flow max: 250 Nm³/h air at 40 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 60/40 bar<br><br>width x height x depth: 1095 x 320 x 160 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "N", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2<br><br>labeld with sticker "not for oxygen use"</p>
6965 <p>free of oil- and grease, for oxygen,consisting of: 2 HP shut-off valve, 2 pressure regulator H40 acc to ISO 7291, single stage, adiabatic compression tested, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 2 solenoid valves 230VAC, 1 double non return valve and 2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p> <p>inlet pressure max: 300 bar<br><br>outlet pressure: 25 bar fixed<br><br>flow max: 125 Nm³/h air at 25 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 60/40 bar<br><br>width x height x depth: 1.095 x 325 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p>
6966 <p>Automatic manifold Vulkan 300 bar Linde free of oil- and grease, for oxygen,consisting of: 2 HP shut-off valve, 2 pressure regulator H20 acc to ISO 7291, single stage, adiabatic compression tested acc. to ISO7291, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 2 solenoid valves 230VAC, 1 double non return valve and 2 distribution blocks, each with an input with sintered filter, non-return valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p> <p>inlet pressure max: 300 bar<br><br>outlet pressure: 15 bar fixed<br><br>flow max: 75 Nm³/h air at 15 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 40/20 bar<br><br>width x height x depth: 1095 x 300 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The product fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p>
6967 <p>free of oil- and grease, for MISON,consisting of: 2 HP shut-off valve, 2 pressure regulator HR20 acc to ISO 7291, single stage, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 2 solenoid valves 230VAC, 1 double non return valve and 2 distribution blocks, each with an input with sintered filter, non-return valve, connection for a safety valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p><p>inlet pressure max: 300 bar<br><br>outlet pressure: 20 bar fixed<br><br>flow max: 160 Nm³/h air at 20 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 40/20 bar<br><br>width x height x depth: 1095 x 475 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "N", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2<br><br>with warning note:"not to use with oxygen"</p>
6968 <p>free of oil- and grease, for oxygen use, consisting of: 2 HP shut-off valve, 2 pressure regulator HR40 acc. to ISO 7291, adiabatic compression tested acc. to ISO 7291 single stage, with metal diaphragm and HP-contact gauges with inductive-contact (NO), 2 solenoid valves 230VAC, 1 double non return valve and 2 distribution blocks, each with an input with sintered filter, non-return valve, connection for a safety valve, purge valve and high-pressure gauge and connection for a cylinder/bundle manifold module, completely mounted on stainless steel base plate</p><p>inlet pressure max: 300 bar<br><br>outlet pressure: 25 bar fixed<br><br>flow max: 250 Nm³/h air at 40 bar outlet pressure <br><br>inlet: 2 x M 20x1,5 RHak -12S usuage for 2x1 cylinders or bundles<br><br>outlet: G 3/4 RH x 18 mm soldered bush<br><br>inlet gauge: 0 – 400/300 bar<br><br>outlet gauge: 0 – 60/40 bar<br><br>width x height x depth: 1095 x 325 x 195 mm<br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p>
12926 Single-cylinder manifold station Vulkan TecLine SE10/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator H10 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 0–10 bar adjustable. Max. flow 50 Nm³/h at 10 bar. With standard pressure gauges. Dimensions: 420 × 260 × 110 mm, 4.5 kg.
12942 Single-cylinder manifold station Vulkan TecLine SE20/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator H20 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 0–20 bar adjustable. Max. flow 75 Nm³/h at 20 bar. With standard pressure gauges. Dimensions: 420 × 320 × 110 mm, 5.0 kg.
12956 Single-bundle acetylene manifold station Vulkan TecLine EB10 (with standard gauges). Complete on stainless steel base plate, acc. to ISO 14114, with HA10 regulator acc. to ISO 7291, automatic quick cut-off valve acc. to ISO 15615, flashback arrestor acc. to ISO 5175, and main shut-off valve. Manual switching. Inlet pressure max 26 bar, outlet pressure 0–1.5 bar. Max. flow 10 Nm³/h at 1.5 bar. Dimensions: 700 × 190 × 160 mm, 14 kg.
12958 Single-bundle acetylene manifold station Vulkan TecLine EB20 (with standard gauges). Complete on stainless steel base plate, acc. to ISO 14114, with HA10/H20 regulator acc. to ISO 7291, automatic quick cut-off valve acc. to ISO 15615, flashback arrestor acc. to ISO 5175, and main shut-off valve. Manual switching. Inlet pressure max 26 bar, outlet pressure 0–1.5 bar. Max. flow 18 Nm³/h at 1.5 bar. Dimensions: 970 × 190 × 160 mm, 16 kg.
12960 Single-bundle manifold station Vulkan TecLine EB60/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator H20 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 0–20 bar. Max. flow 75 Nm³/h at 20 bar. With standard pressure gauges. Dimensions: 420 × 320 × 110 mm, 5.0 kg.
12974 Single-bundle manifold station Vulkan TecLine EB70/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator HR40 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 0–40 bar. Max. flow 120 Nm³/h at 40 bar. With standard pressure gauges. Dimensions: N/A mm, N/A kg.
12988 Single-bundle manifold station Vulkan TecLine EB75/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator HR60 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 0–60 bar. Max. flow 140 Nm³/h at 60 bar. With standard pressure gauges. Dimensions: 370 × 280 × 110 mm, N/A kg.
13000 Single-bundle manifold station Vulkan TecLine EB80/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator HR20 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 0–20 bar. Max. flow 170 Nm³/h at 20 bar. With standard pressure gauges. Dimensions: 440 × 350 × 130 mm, N/A kg.
13014 Single-bundle manifold station Vulkan TecLine EB100/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator HR40 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 15–40 bar. Max. flow 290 Nm³/h at 40 bar. With standard pressure gauges. Dimensions: 440 × 370 × 130 mm, N/A kg.
13028 Single-bundle manifold station Vulkan TecLine EB120/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator HR60 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 15–60 bar. Max. flow 450 Nm³/h at 60 bar. With standard pressure gauges. Dimensions: N/A mm, N/A kg.
13040 Single-bundle manifold station Vulkan TecLine EB200/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator HR200 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 15–200 bar. Max. flow 480 Nm³/h at 200 bar. With standard pressure gauges. Dimensions: 390 × 240 × 240 mm, N/A kg.
13052 Single-bundle manifold station Vulkan TecLine EB270/300. Complete on stainless steel base plate, with HP shut-off valve, manifold fin regulator HR270 acc. to ISO 7291 (adiabatic compression tested), and main shut-off valve. Manual switching. Inlet pressure max 300 bar, outlet pressure 15–270 bar. Max. flow 480 Nm³/h at 270 bar. With standard pressure gauges. Dimensions: 390 × 240 × 240 mm, N/A kg.
13064 Manual manifold base station Vulkan TecLine BS 50/300. Modular add-on system (Modula Vareo). Complete on stainless steel base plate: 1× distributing block Modula Vareo (2 inlets, shut-off valves, non-return valves, sinter-metal filters), 1× manifold fin regulator H10 Effect acc. to ISO 7291 (adiabatic compression tested), 1× main shut-off valve. Manual switching. Inlet max 300 bar, outlet 0–10 bar. Max. flow 50 Nm³/h at 10 bar. Dimensions: 570 × 250 × 210 mm, 10 kg.
13071 Manual manifold base station Vulkan TecLine BS 60/300 Effect. Modular add-on system (Modula Vareo). Complete on stainless steel base plate: 1× distributing block Modula Vareo (2 inlets, shut-off valves, non-return valves, sinter-metal filters), 1× manifold fin regulator H20 Effect acc. to ISO 7291 (adiabatic compression tested), 1× main shut-off valve. Manual switching. Also available with incorporated gas pre-heater GPH 200 or GPH 400. Inlet max 300 bar, outlet 0–20 bar. Max. flow 75 Nm³/h at 20 bar. Dimensions: 570 × 250 × 210 mm, 10 kg.
13078 Manual manifold base station Vulkan TecLine BS 70/300 Effect. Modular add-on system (Modula Vareo). Complete on stainless steel base plate: 1× distributing block Modula Vareo (2 inlets, shut-off valves, non-return valves, sinter-metal filters), 1× manifold fin regulator HR40 Effect acc. to ISO 7291 (adiabatic compression tested), 1× main shut-off valve. Manual switching. Inlet max 300 bar, outlet 0–40 bar. Max. flow 120 Nm³/h at 40 bar. Dimensions: 570 × 250 × 210 mm, 10 kg.
13085 Manual manifold base station Vulkan TecLine BS 75/300 Effect. Modular add-on system (Modula Vareo). Complete on stainless steel base plate: 1× distributing block Modula Vareo (2 inlets, shut-off valves, non-return valves, sinter-metal filters), 1× manifold fin regulator HR60 Effect acc. to ISO 7291 (adiabatic compression tested), 1× main shut-off valve. Manual switching. Inlet max 300 bar, outlet 0–60 bar. Max. flow 140 Nm³/h at 60 bar. Dimensions: 570 × 250 × 210 mm, 10 kg.
13091 Manual manifold base station Vulkan TecLine BS 80/300 Effect. Modular add-on system (Modula Vareo). Complete on stainless steel base plate: 1× distributing block Modula Vareo (2 inlets, shut-off valves, non-return valves, sinter-metal filters), 1× manifold fin regulator HR20 Effect acc. to ISO 7291 (adiabatic compression tested), 1× main shut-off valve. Manual switching. Inlet max 300 bar, outlet 0–20 bar. Max. flow 170 Nm³/h at 20 bar. Dimensions: 590 × 250 × 210 mm, 11 kg.
13098 Manual manifold base station Vulkan TecLine BS 100/300 Effect. Modular add-on system (Modula Vareo). Complete on stainless steel base plate: 1× distributing block Modula Vareo (2 inlets, shut-off valves, non-return valves, sinter-metal filters), 1× manifold fin regulator HR40 Effect acc. to ISO 7291 (adiabatic compression tested), 1× main shut-off valve. Manual switching. Inlet max 300 bar, outlet 15–40 bar. Max. flow 290 Nm³/h at 40 bar. Dimensions: 590 × 270 × 210 mm, 14 kg.
13105 Manual manifold base station Vulkan TecLine BS 120/300 Effect. Modular add-on system (Modula Vareo). Complete on stainless steel base plate: 1× distributing block Modula Vareo (2 inlets, shut-off valves, non-return valves, sinter-metal filters), 1× manifold fin regulator HR60 Effect acc. to ISO 7291 (adiabatic compression tested), 1× main shut-off valve. Manual switching. Inlet max 300 bar, outlet 15–60 bar. Max. flow 450 Nm³/h at 60 bar. Dimensions: 590 × 270 × 210 mm, 14 kg.
13112 Manual manifold base station Vulkan TecLine BS 200/300. Modular add-on system (Modula Vareo). Complete on stainless steel base plate: 1× distributing block Modula Vareo (2 inlets, shut-off valves, non-return valves, sinter-metal filters), 1× manifold manifold regulator LHR 300/200 acc. to ISO 7291 (adiabatic compression tested), 1× main shut-off valve. Manual switching. Inlet max 300 bar, outlet 15–200 bar. Max. flow 480 Nm³/h at 200 bar. Dimensions: 590 × 330 × 285 mm, 12 kg.
13118 Manual manifold base station Vulkan TecLine BS 270/300. Modular add-on system (Modula Vareo). Complete on stainless steel base plate: 1× distributing block Modula Vareo (2 inlets, shut-off valves, non-return valves, sinter-metal filters), 1× manifold manifold regulator acc. to ISO 7291 (adiabatic compression tested), 1× main shut-off valve. Manual switching. Inlet max 300 bar, outlet 15–270 bar. Max. flow 480 Nm³/h at 270 bar. Dimensions: 590 × 330 × 285 mm, 12 kg.
13124 Manual manifold base station for acetylene bundles Vulkan TecLine BSA 10 B. Complete on stainless steel base plate acc. to ISO 14114: 1× distributing block Modula Vareo with automatic quick cut-off valve acc. to ISO 15615, 1× flashback arrestor acc. to ISO 5175, 1× manifold fin regulator HA10 acc. to ISO 7291, 1× main shut-off valve. Manual switching. Inlet max 26 bar, outlet 0–1.5 bar. Max. flow 10 Nm³/h. Dimensions: 850 × 250 × 210 mm, 15 kg.
13125 Manual manifold base station for acetylene bundles Vulkan TecLine BSA 20 B. Complete on stainless steel base plate acc. to ISO 14114: 1× distributing block Modula Vareo with automatic quick cut-off valve acc. to ISO 15615, 1× flashback arrestor acc. to ISO 5175, 1× manifold regulator H20 acetylene acc. to ISO 7291, 1× main shut-off valve. Manual switching. Inlet max 26 bar, outlet 0–1.5 bar. Max. flow 18 Nm³/h. Dimensions: 980 × 250 × 230 mm, 19 kg.
13126 Manual manifold base station for acetylene bundles Vulkan TecLine BSA 40 B. Complete on stainless steel base plate acc. to ISO 14114: 1× distributing block Modula Vareo with automatic quick cut-off valve acc. to ISO 15615, 1× flashback arrestor acc. to ISO 5175, 1× manifold fin regulator HA40 acc. to ISO 7291, 1× main shut-off valve. Manual switching. Inlet max 26 bar, outlet 0–1.5 bar. Max. flow 38 Nm³/h. Dimensions: 980 × 275 × 210 mm, 26 kg.
13162 Automatic switching manifold Vulkan TecLine AM 35/300 K Effect. Complete on stainless steel base plate including: 2× manifold regulator H20 Effect acc. to ISO 7291 (adiabatic compression tested) 1× in-line regulator AD 35 1× automatic change-over block, 1× main shut-off valve. 2× contact gauges acc. to DIN EN 837-1 with Reed switch. Inlet pressure max 300 bar, outlet pressure 0–10 bar. Max. flow 50 Nm³/h. Diaphragm: PTFE. Dimensions: 530 × 400 × 210 mm.
13169 Automatic switching manifold Vulkan TecLine AM 35/300 KH Effect. Complete on stainless steel base plate including: 2× manifold regulator H20 Effect acc. to ISO 7291 (adiabatic compression tested) 1× automatic change-over block, 1× main shut-off valve. 2× contact gauges acc. to DIN EN 837-1 with Reed switch. Inlet pressure max 300 bar, outlet pressure 0–20 bar. Max. flow 75 Nm³/h. Diaphragm: PTFE. Dimensions: 450 × 340 × 210 mm.
13176 Automatic switching manifold Vulkan TecLine AM 35/300 H Effect. Complete on stainless steel base plate including: 2× manifold regulator H20 Effect acc. to ISO 7291 (adiabatic compression tested) 1× automatic change-over block, 1× main shut-off valve. Inlet pressure max 300 bar, outlet pressure 0–20 bar. Max. flow 75 Nm³/h. Diaphragm: PTFE. Dimensions: 450 × 340 × 210 mm.
13183 Automatic switching manifold Vulkan TecLine AM 40/300 K Effect. Complete on stainless steel base plate including: 2× manifold fin regulator HR40 Effect acc. to ISO 7291 (adiabatic compression tested) 1× automatic change-over block, 1× main shut-off valve. 2× contact gauges acc. to DIN EN 837-1 with Reed switch. Inlet pressure max 300 bar, outlet pressure 0–28 bar. Max. flow 120 Nm³/h. Diaphragm: PTFE. Dimensions: 530 × 400 × 210 mm.
13190 Automatic switching manifold Vulkan TecLine AM 40/300 Effect. Complete on stainless steel base plate including: 2× manifold fin regulator HR40 Effect acc. to ISO 7291 (adiabatic compression tested) 1× automatic change-over block, 1× main shut-off valve. Inlet pressure max 300 bar, outlet pressure 0–28 bar. Max. flow 120 Nm³/h. Diaphragm: PTFE. Dimensions: 530 × 400 × 210 mm.
13197 Automatic switching manifold Vulkan TecLine AM 45/300 K Effect. Complete on stainless steel base plate including: 2× manifold fin regulator HR20 Effect acc. to ISO 7291 (adiabatic compression tested) 1× automatic change-over block, 1× main shut-off valve. 2× contact gauges acc. to DIN EN 837-1 with Reed switch. Inlet pressure max 300 bar, outlet pressure 0–20 bar. Max. flow 170 Nm³/h. Diaphragm: PTFE. Dimensions: 500 × 370 × 230 mm.
13204 Automatic switching manifold Vulkan TecLine AM 45/300 Effect. Complete on stainless steel base plate including: 2× manifold fin regulator HR20 Effect acc. to ISO 7291 (adiabatic compression tested) 1× automatic change-over block, 1× main shut-off valve. Inlet pressure max 300 bar, outlet pressure 0–20 bar. Max. flow 170 Nm³/h. Diaphragm: PTFE. Dimensions: 500 × 370 × 230 mm.
13211 Automatic switching manifold Vulkan TecLine AM 55/300 K Effect. Complete on stainless steel base plate including: 2× manifold fin regulator HR40 Effect acc. to ISO 7291 (adiabatic compression tested) 1× automatic change-over block, 1× main shut-off valve. 2× contact gauges acc. to DIN EN 837-1 with Reed switch. Inlet pressure max 300 bar, outlet pressure 0–28 bar. Max. flow 250 Nm³/h. Diaphragm: Rubber (SS for O₂). Dimensions: 500 × 380 × 230 mm.
13218 Automatic switching manifold Vulkan TecLine AM 55/300 Effect. Complete on stainless steel base plate including: 2× manifold fin regulator HR40 Effect acc. to ISO 7291 (adiabatic compression tested) 1× automatic change-over block, 1× main shut-off valve. Inlet pressure max 300 bar, outlet pressure 0–28 bar. Max. flow 250 Nm³/h. Diaphragm: Rubber (SS for O₂). Dimensions: 500 × 380 × 230 mm.
13225 Automatic switching manifold Vulkan TecLine AM 35/300 KM Effect. Complete on stainless steel base plate including: 2× manifold regulator H20 Effect acc. to ISO 7291 (adiabatic compression tested) 1× in-line regulator AD 35 2× solenoid valves 24V AC, normally closed 1× automatic change-over block, 1× main shut-off valve. 2× contact gauges acc. to DIN EN 837-1 with Reed switch. Inlet pressure max 300 bar, outlet pressure 0–10 bar. Max. flow 50 Nm³/h. Diaphragm: PTFE. Dimensions: 690 × 430 × 210 mm.
13232 Automatic switching manifold Vulkan TecLine AM 35/300 KHM Effect. Complete on stainless steel base plate including: 2× manifold regulator H20 Effect acc. to ISO 7291 (adiabatic compression tested) 2× solenoid valves 24V AC, normally closed 1× automatic change-over block, 1× main shut-off valve. 2× contact gauges acc. to DIN EN 837-1 with Reed switch. Inlet pressure max 300 bar, outlet pressure 0–20 bar. Max. flow 75 Nm³/h. Diaphragm: PTFE. Dimensions: 690 × 350 × 210 mm.
13239 Automatic switching manifold Vulkan TecLine AM 40/300 KM Effect. Complete on stainless steel base plate including: 2× manifold regulator H40 Effect acc. to ISO 7291 (adiabatic compression tested) 2× solenoid valves 24V AC, normally closed 1× automatic change-over block, 1× main shut-off valve. 2× contact gauges acc. to DIN EN 837-1 with Reed switch. Inlet pressure max 300 bar, outlet pressure 0–40 bar. Max. flow 120 Nm³/h. Diaphragm: PTFE (SS for O₂). Dimensions: 690 × 350 × 210 mm.
13246 Automatic switching manifold Vulkan TecLine AM 45/300 KM Effect. Complete on stainless steel base plate including: 2× manifold fin regulator HR20 Effect acc. to ISO 7291 (adiabatic compression tested) 2× solenoid valves 24V AC, normally closed 1× automatic change-over block, 1× main shut-off valve. 2× contact gauges acc. to DIN EN 837-1 with Reed switch. Inlet pressure max 300 bar, outlet pressure 0–20 bar. Max. flow 170 Nm³/h. Diaphragm: Rubber. Dimensions: 720 × 385 × 210 mm.
13253 Automatic switching manifold Vulkan TecLine AM 55/300 KM Effect. Complete on stainless steel base plate including: 2× manifold fin regulator HR40 Effect acc. to ISO 7291 (adiabatic compression tested) 2× solenoid valves 24V AC, normally closed 1× automatic change-over block, 1× main shut-off valve. 2× contact gauges acc. to DIN EN 837-1 with Reed switch. Inlet pressure max 300 bar, outlet pressure 0–40 bar. Max. flow 250 Nm³/h. Diaphragm: Rubber (SS for O₂). Dimensions: 720 × 385 × 210 mm.
13298 Manifold station Modula Vareo VS for oxygen, inert and fuel gases (except acetylene). Vareo distribution block with 2 inlets M 24×1.5 RH for connecting 2 cylinders or bundles up to 300 bar. Equipped with 2 sinter filters, 2 non-return valves (NRV), 2 shut-off valves, and 2 connections for additional manifold stations or base station Vareo. Fully assembled on base plate. Material: brass. Dimensions: 195 × 205 × 240 mm.
13299 Manifold station Modula Vareo VS for acetylene. Vareo distribution block with 2 inlets W 21.8×1/14 LH for connecting 2 cylinders or bundles up to 300 bar. Equipped with 2 sinter filters, 2 non-return valves (NRV), 2 shut-off valves, and 2 connections for additional manifold stations or base station Vareo. Fully assembled on base plate. Material: brass. Dimensions: 195 × 205 × 240 mm.
13300 Manifold station Modula Vareo VSD for oxygen, inert and fuel gases (except acetylene). Without non-return valve and sinter filter. Vareo distribution block with 2 inlets M 24×1.5 RH for connecting 2 cylinders or bundles up to 300 bar. 2 shut-off valves and 2 connections for additional manifold stations or base station Vareo. Fully assembled on base plate. Material: brass. Dimensions: 195 × 205 × 240 mm.
13301 Manifold station Modula Vareo VSL for oxygen, inert and fuel gases (except acetylene). Without shut-off valve. Vareo distribution block with 2 inlets M 24×1.5 RH for connecting 2 cylinders or bundles up to 300 bar. 2 sinter filters, 2 non-return valves and 2 connections for additional manifold stations or base station Vareo. Fully assembled on base plate. Material: brass. Dimensions: 195 × 205 × 240 mm.
13302 Connecting pipe Vareo VB 90° bent, 2 × 150 mm. Copper tube, DN10, PN300. Inlet: M 24×1.5 RH U-nut. Outlet: M 24×1.5 RH U-nut. Manifold station → base station, for cylinders.
13303 Connecting pipe Vareo VB 90° bent Acetylene, 2 × 150 mm. Steel tube, DN10, PN300. Inlet: M 24×1.5 RH U-nut. Outlet: W 21.8×1/14 LH U-nut. Manifold station → base station, for cylinders.
13304 Connecting pipe Vareo VU 2×bent (offset), 300 mm. Copper tube, DN10, PN300. Inlet: M 24×1.5 RH U-nut. Outlet: M 24×1.5 RH U-nut. Manifold station → automatic manifold, for cylinders.
13305 Connecting pipe Vareo VU 2×bent (offset) Acetylene, 400 mm. Steel tube, DN10, PN26. Inlet: M 24×1.5 RH U-nut. Outlet: M 24×1.5 RH U-nut. Manifold station → automatic manifold, for cylinders.
13306 Connecting pipe Vareo VF straight, 400 mm. Copper tube, DN10, PN300. Inlet: M 24×1.5 RH U-nut. Outlet: M 24×1.5 RH U-nut. Between two manifold stations, for cylinders.
13307 Connecting pipe Vareo VF straight Acetylene, 400 mm. Steel tube, DN10, PN26. Inlet: M 24×1.5 RH U-nut. Outlet: M 24×1.5 RH U-nut. Between two manifold stations, for cylinders.
13308 Connecting pipe Vareo VBP 90° bent, 900 × 150 mm. Copper tube, DN10, PN300. Inlet: M 24×1.5 RH U-nut. Outlet: M 24×1.5 RH U-nut. Manifold station → base station, for bundles.
13309 Connecting pipe Vareo VBP 90° bent Acetylene, 900 × 150 mm. Steel tube, DN10, PN300. Inlet: M 24×1.5 RH U-nut. Outlet: M 24×1.5 RH U-nut. Manifold station → base station, for bundles.
13310 Connecting pipe Vareo VP straight, 900 mm. Copper tube, DN10, PN300. Inlet: M 24×1.5 RH U-nut. Outlet: M 24×1.5 RH U-nut. Between two manifold stations, for bundles.
13311 Connecting pipe Vareo VP straight Acetylene, 900 mm. Steel tube, DN10, PN26. Inlet: M 24×1.5 RH U-nut. Outlet: M 24×1.5 RH U-nut. Between two manifold stations, for bundles.
13312 Connecting pipe Vareo VPU 2×bent (offset), 900 mm. Copper tube, DN10, PN300. Inlet: M 24×1.5 RH U-nut. Outlet: M 24×1.5 RH U-nut. Manifold station → automatic manifold, for bundles.
13313 Connecting pipe Vareo VPU 2×bent (offset) Acetylene, 900 mm. Steel tube, DN10, PN26. Inlet: M 24×1.5 RH U-nut. Outlet: M 24×1.5 RH U-nut. Manifold station → automatic manifold, for bundles.
13314 Purge valve Vareo for Vareo VS/BS with clamp ring compression fitting 10 mm. For purging one inlet on the Vareo block, integrated in Vareo distribution block. Complete with clamp ring compression fitting 10 mm at outlet for blow-off pipe connection. Note: when retrofitting into Vareo block, the spindle must be set and checked for tightness.
13315 Purge valve Vareo for Vareo VS/BS with angle valve EV UM M24×1.5RH-16S, for all technical gases except acetylene. Inlet: U-nut M 24×1.5 RH.
13316 Purge valve Vareo for Vareo VS/BS with angle valve EV UM M24×1.5RH-16S, for acetylene. Inlet: U-nut M 24×1.5 RH.
13317 Rail system Vulkan Modula FN 1-cylinder with non-return valve, left mounting. 1 inlet M 24×1.5 RH with non-return valve and sinter filter. Brass body, max 300 bar. Width: 125 mm.
13318 Rail system Vulkan Modula FN 1-cylinder with non-return valve, right mounting. 1 inlet M 24×1.5 RH with non-return valve and sinter filter. Brass body, max 300 bar. Width: 125 mm.
13319 Cylinder rack Vulkan Modula for securing gas cylinders against tipping. Fully stainless steel construction with wall fixture, chain with snap hook, and edge protection. For 1 cylinder. Width: 280 mm.