Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
| 64 |
|
<p>Working pressure reducer Vulkan AD 35 nitrogen 0 - 10 bar for AM 35, single-stage design, with safety pressure gauge according to DIN EN ISO 5171. Maximum inlet pressure: 20 bar. Output pressure: 0 - 10 bar, adjustable. Maximum output: 50 Nm³/h air at 10 bar outlet pressure. Inlet: G1/2" male thread, threaded connection according to DIN EN 560. Outlet: G3/8" male thread, threaded connection according to DIN EN 560. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 89 x 166 x 134 mm. This line pressure reducer is available in the following versions: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a gas purity of 5.0 with a stainless steel diaphragm. SS321 (1.4541)</p> |
|
|
|
|
| 104 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 105 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 106 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 107 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 108 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 109 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 110 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 118 |
|
<p>Working pressure reducer Vulkan AD 35 nitrogen 0 - 10 bar for AM 35, single-stage design, with safety pressure gauge according to DIN EN ISO 5171. Maximum inlet pressure: 20 bar. Output pressure: 0 - 10 bar, adjustable. Maximum output: 50 Nm³/h air at 10 bar outlet pressure. Inlet: G1/2" male thread, threaded connection according to DIN EN 560. Outlet: G3/8" male thread, threaded connection according to DIN EN 560. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 89 x 166 x 134 mm. This line pressure reducer is available in the following versions: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a gas purity of 5.0 with a stainless steel diaphragm. SS321 (1.4541)</p> |
|
|
|
|
| 203 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 204 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 205 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 206 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 207 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 208 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 209 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 224 |
|
<p>Working pressure reducer Vulkan AD 35 nitrogen 0 - 10 bar for AM 35, single-stage design, with safety pressure gauge according to DIN EN ISO 5171. Maximum inlet pressure: 20 bar. Output pressure: 0 - 10 bar, adjustable. Maximum output: 50 Nm³/h air at 10 bar outlet pressure. Inlet: G1/2" male thread, threaded connection according to DIN EN 560. Outlet: G3/8" male thread, threaded connection according to DIN EN 560. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 89 x 166 x 134 mm. This line pressure reducer is available in the following versions: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a gas purity of 5.0 with a stainless steel diaphragm. SS321 (1.4541)</p> |
|
|
|
|
| 225 |
|
<p>Working pressure reducer Vulkan AD 35 nitrogen 0 - 10 bar for AM 35, single-stage design, with safety pressure gauge according to DIN EN ISO 5171. Maximum inlet pressure: 20 bar. Output pressure: 0 - 10 bar, adjustable. Maximum output: 50 Nm³/h air at 10 bar outlet pressure. Inlet: G1/2" male thread, threaded connection according to DIN EN 560. Outlet: G3/8" male thread, threaded connection according to DIN EN 560. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 89 x 166 x 134 mm. This line pressure reducer is available in the following versions: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a gas purity of 5.0 with a stainless steel diaphragm. SS321 (1.4541)</p> |
|
|
|
|
| 285 |
|
<p>Working pressure reducer Vulkan AD 35 nitrogen 0 - 10 bar for AM 35, single-stage design, with safety pressure gauge according to DIN EN ISO 5171. Maximum inlet pressure: 20 bar. Output pressure: 0 - 10 bar, adjustable. Maximum output: 50 Nm³/h air at 10 bar outlet pressure. Inlet: G1/2" male thread, threaded connection according to DIN EN 560. Outlet: G3/8" male thread, threaded connection according to DIN EN 560. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 89 x 166 x 134 mm. This line pressure reducer is available in the following versions: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a gas purity of 5.0 with a stainless steel diaphragm. SS321 (1.4541)</p> |
|
|
|
|
| 324 |
|
<p>Vulkan L10 line pressure reducer for compressed air G1/2RH both sides, 0-10 bar, based on ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 20 bar. Output pressure: 0-10 bar, adjustable. Maximum output: 45 Nm³/h at 10 bar outlet pressure. Inlet: G1/2RHak according to EN 560. Outlet: G1/2RHak according to EN 560. Inlet pressure gauge: 0-40/20 bar. Outlet pressure gauge: 0-16/10 bar. Width x Height x Depth: 210 x 190 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm. Optional (Surcharge):- for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order numberGas purity/membraneInlet/outlet screw connection 107529 for technical gases up to 4.5, with standard membrane on both sides. external thread G1/2" RHk according to EN 560 107529-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 107529-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 107529-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107529-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107529-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107529-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107529-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107529-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107529-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107529-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107529-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107529-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107529-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 339 |
|
<p>Working pressure reducer Vulkan AD 35 nitrogen 0 - 10 bar for AM 35, single-stage design, with safety pressure gauge according to DIN EN ISO 5171. Maximum inlet pressure: 20 bar. Output pressure: 0 - 10 bar, adjustable. Maximum output: 50 Nm³/h air at 10 bar outlet pressure. Inlet: G1/2" male thread, threaded connection according to DIN EN 560. Outlet: G3/8" male thread, threaded connection according to DIN EN 560. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 89 x 166 x 134 mm. This line pressure reducer is available in the following versions: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a gas purity of 5.0 with a stainless steel diaphragm. SS321 (1.4541)</p> |
|
|
|
|
| 1345 |
|
Line dome pressure reducer Vulkan LD1 PN40 with control pressure reducer complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 40 bar, output pressure: 0.5 - 25 bar adjustable, maximum output: 1,700 Nm³/h air at 25 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
| 1346 |
|
Line dome pressure reducer Vulkan LD1 PN40 with control pressure reducer complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 40 bar, output pressure: 0.5 - 25 bar adjustable, maximum output: 1,700 Nm³/h air at 25 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
| 1347 |
|
Line dome pressure reducer Vulkan LD1 PN40 with control pressure reducer complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 40 bar, output pressure: 0.5 - 25 bar adjustable, maximum output: 1,700 Nm³/h air at 25 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
| 1348 |
|
Line dome pressure reducer Vulkan LD1 PN40 with control pressure reducer complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 40 bar, output pressure: 0.5 - 25 bar adjustable, maximum output: 1,700 Nm³/h air at 25 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
| 1349 |
|
Line dome pressure reducer Vulkan LD1 PN40 with control pressure reducer complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 40 bar, output pressure: 0.5 - 25 bar adjustable, maximum output: 1,700 Nm³/h air at 25 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
| 1350 |
|
Line dome pressure reducer Vulkan LD1 PN40 with control pressure reducer complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 40 bar, output pressure: 0.5 - 25 bar adjustable, maximum output: 1,700 Nm³/h air at 25 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
| 1351 |
|
Line dome pressure reducer Vulkan LD1 PN40 with control pressure reducer complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 40 bar, output pressure: 0.5 - 25 bar adjustable, maximum output: 1,700 Nm³/h air at 25 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
| 1352 |
|
Line dome pressure reducer Vulkan LD1 PN40 with control pressure reducer complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 40 bar, output pressure: 0.5 - 25 bar adjustable, maximum output: 1,700 Nm³/h air at 25 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
| 1353 |
|
Line dome pressure reducer Vulkan LD1 PN40 with control pressure reducer complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 40 bar, output pressure: 0.5 - 25 bar adjustable, maximum output: 1,700 Nm³/h air at 25 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
| 1354 |
|
Line dome pressure reducer Vulkan LD1 PN40 with control pressure reducer complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 40 bar, output pressure: 0.5 - 25 bar adjustable, maximum output: 1,700 Nm³/h air at 25 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
| 3096 |
|
Line pressure reducer Vulkan L10 acetylene G1/2RHak external thread on both sides<br />Standards & Design:<br /><br />Single-stage design, with safety pressure gauges according to DIN EN ISO 5171<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 1<br />• outlet pressure<br />• Output pressure: 0 - 1<br />• Inlet: external thread G1/2RHak, Outlet: external thread G1/2RHak<br />• Outlet: external thread G1/2RHak<br />• Inlet pressure gauge: 0 - 2<br />• Outlet pressure gauge: 0 - 2<br /><br />Dimensions:<br /><br />Width x Height x Depth: 162 x 190 x 75 mm |
|
|
|
|
| 3104 |
|
Vulkan LHR3 line pressure reducer for compressed air G 2RHi, 0.3 - 3.0 bar<br />Standards & Design:<br /><br />single-stage design, without pressure gauge<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 6 bar<br />• outlet pressure<br />• Output pressure: 0<br /><br />Dimensions:<br /><br />Width x Height x Depth: 240 x 300 x 240 mm |
|
|
|
|
| 3105 |
|
Vulkan LP216 line pressure reducer for compressed air G1/4RHi, 1 - 250 mbar<br />Standards & Design:<br /><br />single-stage design, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 21 bar, output pressure: 1 - 250 mbar, adjustable<br /><br />Technical data:<br /><br />• maximum inlet pressure: 21 bar, output pressure: 1 - 250 mbar, adjustable<br />• output pressure: 1 - 250 mbar, adjustable<br />• Inlet: internal thread G1/4RHi, output: internal thread G1/4RHi, output gauge: 0 - 250 mbar<br /><br />Dimensions:<br /><br />Width x Height x Depth: 108 x 162 x 108 mm |
|
|
|
|
| 3107 |
|
Vulkan L15 line pressure reducer for compressed air G1/2RH, 0 - 1.5 bar<br />Standards & Design:<br /><br />single-stage design with safety pressure gauges according to DIN ISO 5171<br />according to EN 560<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 20 bar<br />• outlet pressure<br />• Output pressure: 0 - 1<br />• Inlet: external thread G1/2RH according to EN 560<br />• Outlet: external thread G1/2RH according to EN 560<br />• Inlet pressure gauge: 0 - 40/20 bar<br />• Outlet pressure gauge: 0 - 2<br /><br />Dimensions:<br /><br />Width x Height x Depth: 200 x 200 x 75 mm |
|
|
|
|
| 3111 |
|
In-line dome pressure reducer Vulkan LD1 MD Helium G1RHi, 0.5 - 99 bar, both sides, not for carbon dioxide. Material: Brass/Viton<br />Standards & Design:<br /><br />Single-stage design<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 100 bar<br />• outlet pressure<br />• Output pressure: 0<br />• Inlet: Internal thread G1RHi<br />• Outlet: Internal thread G1RHi<br /><br />Dimensions:<br /><br />Width x Height x Depth: 130 x 170 x 130 mm |
|
|
|
|
| 3112 |
|
Line dome pressure reducer Vulkan LD1 MD inert gases G1RHi both sides. 0.5 - 99 bar not for carbon dioxide, material: brass / Viton<br />Standards & Design:<br /><br />single-stage design, maximum inlet pressure: 100 bar, output pressure: 0<br /><br />Technical data:<br /><br />• maximum inlet pressure: 100 bar, output pressure: 0<br />• outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: without, output pressure gauge: without, width x height x depth: 130 x 170 x 130 mm<br />• output pressure: 0<br /><br />Dimensions:<br /><br />width x height x depth: 130 x 170 x 130 mm |
|
|
|
|
| 3118 |
|
Line pressure reducer Vulkan LP216 Helium G1/4RHi, 1 - 250 mbar<br />Standards & Design:<br /><br />single-stage design, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 21 bar, output pressure: 1 - 250 mbar, adjustable<br /><br />Technical data:<br /><br />• maximum inlet pressure: 21 bar, output pressure: 1 - 250 mbar, adjustable<br />• output pressure: 1 - 250 mbar, adjustable<br />• Inlet: internal thread G1/4RHi, output: internal thread G1/4RHi, output gauge: 0 - 250 mbar<br /><br />Dimensions:<br /><br />Width x Height x Depth: 108 x 162 x 108 mm |
|
|
|
|
| 3122 |
|
Vulkan L15 line pressure reducer for fuel gases G1/2RH, 0 - 1.5 bar<br />Standards & Design:<br /><br />single-stage design, with safety pressure gauges according to DIN ISO 5171, maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br /><br />Technical data:<br /><br />• maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />• outlet pressure, input: external thread G1/2RH according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br />• output pressure: 0 to 1<br /><br />Dimensions:<br /><br />width x height x depth: 200 x 200 x 75 mm |
|
|
|
|
| 3124 |
|
In-line dome pressure reducer Vulkan LD1 MD hydrogen G1RHi, both sides 0.5 - 99 bar. Materials: Brass<br />Standards & Design:<br /><br />single-stage design, maximum inlet pressure: 100 bar<br /><br />Technical data:<br /><br />• maximum inlet pressure: 100 bar<br />• outlet pressure<br />• Output pressure: 0<br />• Inlet: internal thread G1RHi, outlet: internal thread G1RHi<br />• outlet: internal thread G1RHi<br /><br />Dimensions:<br /><br />Width x Height x Depth: 130 x 170 x 130 mm |
|
|
|
|
| 3144 |
|
In-line dome pressure reducer Vulkan LD1 PN50 nitrogen, with control pressure reducer and pressure gauges. Complete with control pressure reducer. Material: brass/Viton<br />Standards & Design:<br /><br />Single-stage design<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 50 bar<br />• outlet pressure<br />• Output pressure: 0<br />• Inlet: internal thread G1RHi<br />• Outlet: internal thread G1RHi<br />• Inlet pressure gauge: 0-50<br />• Outlet pressure gauge: 0 - 49 bar |
|
|
|
|
| 3145 |
|
In-line dome pressure reducer Vulkan LD1 PN50 helium, with control pressure reducer and pressure gauges, complete with control pressure reducer, material: brass/Viton<br />Standards & Design:<br /><br />single-stage design, maximum inlet pressure: 50 bar, output pressure: 0<br /><br />Technical data:<br /><br />• maximum inlet pressure: 50 bar, output pressure: 0<br />• outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: 0-50, output pressure gauge: 0 - 49 bar<br />• output pressure: 0 |
|
|
|
|
| 3147 |
|
In-line dome pressure reducer Vulkan LD1 PN50 nitrogen, with control pressure reducer and<br />Standards & Design:<br /><br />single-stage design, maximum inlet pressure: 50 bar, output pressure: 0<br /><br />Technical data:<br /><br />• maximum inlet pressure: 50 bar, output pressure: 0<br />• outlet pressure gauge complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 50 bar, output pressure: 0<br />• output pressure: 0<br />• inlet: internal thread G1RHi, outlet: internal thread G1RHi, input pressure gauge: without, output pressure gauge: 0 - 49 bar<br />• outlet: internal thread G1RHi, input pressure gauge: without, output pressure gauge: 0 - 49 bar<br />• outlet pressure gauge complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 50 bar, output pressure: 0 |
|
|
|
|
| 3148 |
|
In-line dome pressure reducer Vulkan LD1 PN50 hydrogen, with control pressure reducer and<br />Standards & Design:<br /><br />single-stage design, maximum inlet pressure: 50 bar, output pressure: 0<br /><br />Technical data:<br /><br />• maximum inlet pressure: 50 bar, output pressure: 0<br />• outlet pressure gauge complete, with control pressure reducer, material: brass/Viton, single-stage design, maximum inlet pressure: 50 bar, output pressure: 0<br />• output pressure: 0<br />• inlet: internal thread G1RHi, outlet: internal thread G1RHi, input pressure gauge: without, output pressure gauge: 0 - 49 bar<br />• outlet: internal thread G1RHi, input pressure gauge: without, output pressure gauge: 0 - 49 bar<br />• outlet pressure gauge complete, with control pressure reducer, material: brass/Viton, single-stage design, maximum inlet pressure: 50 bar, output pressure: 0 |
|
|
|
|
| 3150 |
|
In-line dome pressure reducer Vulkan LD1 PN40 oxygen, with control pressure reducer and<br />Standards & Design:<br /><br />single-stage design, max<br /><br />Technical data:<br /><br />• outlet pressure gauge complete, with control pressure reducer, material: brass / Viton, single-stage design, max<br />• output: 1,900 Nm³/h air at 35 bar outlet pressure, inlet: internal thread G1RHi, outlet: internal thread G1RHi, inlet pressure gauge: without, outlet pressure gauge: 0 - 49 bar<br />• inlet: internal thread G1RHi, outlet: internal thread G1RHi, inlet pressure gauge: without, outlet pressure gauge: 0 - 49 bar<br />• outlet: internal thread G1RHi, inlet pressure gauge: without, outlet pressure gauge: 0 - 49 bar<br />• inlet pressure gauge: without, outlet pressure gauge: 0 - 49 bar<br />• outlet pressure gauge complete, with control pressure reducer, material: brass / Viton, single-stage design, max |
|
|
|
|
| 3151 |
|
Line dome pressure reducer Vulkan LD1 PN50 Helium, with control pressure reducer complete, with control pressure reducer, material: brass / Viton<br />Standards & Design:<br /><br />single-stage design, max<br /><br />Technical data:<br /><br />• outlet pressure: 0<br />• output: 2,100 Nm?/h air at 35 bar outlet pressure (200 Nm?/h air at 49 bar outlet pressure) Inlet: internal thread G1RHi, outlet: internal thread G1RHi, input pressure gauge: without, output pressure gauge: without<br />• Inlet: internal thread G1RHi, outlet: internal thread G1RHi, input pressure gauge: without, output pressure gauge: without<br />• outlet: internal thread G1RHi, input pressure gauge: without, output pressure gauge: without |
|
|
|
|
| 3698 |
|
Line dome pressure reducer Vulkan LD1 PN40 with control pressure reducer complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 40 bar, output pressure: 0.5 - 25 bar adjustable, maximum output: 1,700 Nm³/h air at 25 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
| 3699 |
|
Line dome pressure reducer Vulkan LD1 PN40 with control pressure reducer complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 40 bar, output pressure: 0.5 - 25 bar adjustable, maximum output: 1,700 Nm³/h air at 25 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
| 3700 |
|
Line dome pressure reducer Vulkan LD1 PN40 with control pressure reducer complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 40 bar, output pressure: 0.5 - 25 bar adjustable, maximum output: 1,700 Nm³/h air at 25 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
| 3701 |
|
Line dome pressure reducer Vulkan LD1 PN40 with control pressure reducer complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 40 bar, output pressure: 0.5 - 25 bar adjustable, maximum output: 1,700 Nm³/h air at 25 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
| 3702 |
|
Line dome pressure reducer Vulkan LD1 PN40 with control pressure reducer complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 40 bar, output pressure: 0.5 - 25 bar adjustable, maximum output: 1,700 Nm³/h air at 25 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
| 3703 |
|
Line dome pressure reducer Vulkan LD1 PN40 with control pressure reducer complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 40 bar, output pressure: 0.5 - 25 bar adjustable, maximum output: 1,700 Nm³/h air at 25 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
| 3704 |
|
Line dome pressure reducer Vulkan LD1 PN40 with control pressure reducer complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 40 bar, output pressure: 0.5 - 25 bar adjustable, maximum output: 1,700 Nm³/h air at 25 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
| 3705 |
|
Line dome pressure reducer Vulkan LD1 PN40 with control pressure reducer complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 40 bar, output pressure: 0.5 - 25 bar adjustable, maximum output: 1,700 Nm³/h air at 25 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
| 3706 |
|
Line dome pressure reducer Vulkan LD1 PN40 with control pressure reducer complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 40 bar, output pressure: 0.5 - 25 bar adjustable, maximum output: 1,700 Nm³/h air at 25 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
| 3707 |
|
Line dome pressure reducer Vulkan LD1 PN40 with control pressure reducer complete, with control pressure reducer, material: brass / Viton, single-stage design, maximum inlet pressure: 40 bar, output pressure: 0.5 - 25 bar adjustable, maximum output: 1,700 Nm³/h air at 25 bar outlet pressure, input: internal thread G1RHi, output: internal thread G1RHi, input pressure gauge: optional (add in the selection window), output pressure gauge: optional (add in the selection window) |
|
|
|
|
| 3863 |
|
In-line dome pressure reducer Vulkan LD1 PN50 hydrogen, with control pressure reducer and pressure gauges, complete, with control pressure reducer, material: brass/Viton<br />Standards & Design:<br /><br />single-stage design, maximum inlet pressure: 50 bar, output pressure: 0<br /><br />Technical data:<br /><br />• maximum inlet pressure: 50 bar, output pressure: 0<br />• outlet pressure, inlet: internal thread G1RHi, outlet: internal thread G1RHi, input pressure gauge: 0-50, output pressure gauge: 0 - 49 bar<br />• output pressure: 0<br />• inlet: internal thread G1RHi, outlet: internal thread G1RHi, input pressure gauge: 0-50, output pressure gauge: 0 - 49 bar<br />• outlet: internal thread G1RHi, input pressure gauge: 0-50, output pressure gauge: 0 - 49 bar |
|
|
|
|
| 3864 |
|
Line dome pressure reducer Vulkan LD1 PN50 Helium, with control pressure reducer complete, with control pressure reducer, material: brass / Viton<br />Standards & Design:<br /><br />single-stage design, max<br /><br />Technical data:<br /><br />• outlet pressure: 0<br />• output: 2,100 Nm?/h air at 35 bar outlet pressure (200 Nm?/h air at 49 bar outlet pressure) Inlet: internal thread G1RHi, outlet: internal thread G1RHi, input pressure gauge: without, output pressure gauge: without<br />• Inlet: internal thread G1RHi, outlet: internal thread G1RHi, input pressure gauge: without, output pressure gauge: without<br />• outlet: internal thread G1RHi, input pressure gauge: without, output pressure gauge: without |
|
|
|
|
| 3975 |
|
<p>Working pressure reducer Vulkan AD 35 nitrogen 0 - 10 bar for AM 35, single-stage design, with safety pressure gauge according to DIN EN ISO 5171. Maximum inlet pressure: 20 bar. Output pressure: 0 - 10 bar, adjustable. Maximum output: 50 Nm³/h air at 10 bar outlet pressure. Inlet: G1/2" male thread, threaded connection according to DIN EN 560. Outlet: G3/8" male thread, threaded connection according to DIN EN 560. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 89 x 166 x 134 mm. This line pressure reducer is available in the following versions: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a gas purity of 5.0 with a stainless steel diaphragm. SS321 (1.4541)</p> |
|
|
|
|
| 4013 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 4014 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 4015 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 4016 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 4017 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 4018 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 4019 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 4027 |
|
<p>Working pressure reducer Vulkan AD 35 nitrogen 0 - 10 bar for AM 35, single-stage design, with safety pressure gauge according to DIN EN ISO 5171. Maximum inlet pressure: 20 bar. Output pressure: 0 - 10 bar, adjustable. Maximum output: 50 Nm³/h air at 10 bar outlet pressure. Inlet: G1/2" male thread, threaded connection according to DIN EN 560. Outlet: G3/8" male thread, threaded connection according to DIN EN 560. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 89 x 166 x 134 mm. This line pressure reducer is available in the following versions: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a gas purity of 5.0 with a stainless steel diaphragm. SS321 (1.4541)</p> |
|
|
|
|
| 4087 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 4088 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 4089 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 4090 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 4091 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 4092 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 4093 |
|
<p>Vulkan L40 line pressure reducer for compressed air G1/2RH both sides, 0 - 40 bar, based on DIN EN ISO 7291, single-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 100 bar. Output pressure: 0 - 40 bar, adjustable. Maximum output: 90 Nm³/h at 40 bar outlet pressure. Inlet connection: G1/2RHak according to DIN EN 560. Outlet connection: G1/2RHak according to DIN EN 560. Inlet pressure gauge: 0 - 160 / 100 bar. Outlet pressure gauge: 0 - 60 / 40 bar. Width x Height x Depth: 165 x 210 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with Standard membrane Optional (surcharge): - for pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107523 for technical gases up to 4.5, with standard membrane, external thread G1/2" RHk on both sides according to EN 560 107523-6M-6M for technical gases up to 4.5, with standard membrane, compression fitting VA 6mm on both sides 107523-8M-8M for technical gases up to 4.5, with standard membrane, compression fitting VA 8mm on both sides 107523-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10mm 107523-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 12mm 107523-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 15mm 107523-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 18mm 107523-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107523-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 6mm 107523-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 8mm 107523-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 10mm 107523-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 12mm 107523-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 15mm 107523-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 4108 |
|
<p>Working pressure reducer Vulkan AD 35 nitrogen 0 - 10 bar for AM 35, single-stage design, with safety pressure gauge according to DIN EN ISO 5171. Maximum inlet pressure: 20 bar. Output pressure: 0 - 10 bar, adjustable. Maximum output: 50 Nm³/h air at 10 bar outlet pressure. Inlet: G1/2" male thread, threaded connection according to DIN EN 560. Outlet: G3/8" male thread, threaded connection according to DIN EN 560. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 89 x 166 x 134 mm. This line pressure reducer is available in the following versions: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a gas purity of 5.0 with a stainless steel diaphragm. SS321 (1.4541)</p> |
|
|
|
|
| 4109 |
|
<p>Working pressure reducer Vulkan AD 35 nitrogen 0 - 10 bar for AM 35, single-stage design, with safety pressure gauge according to DIN EN ISO 5171. Maximum inlet pressure: 20 bar. Output pressure: 0 - 10 bar, adjustable. Maximum output: 50 Nm³/h air at 10 bar outlet pressure. Inlet: G1/2" male thread, threaded connection according to DIN EN 560. Outlet: G3/8" male thread, threaded connection according to DIN EN 560. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 89 x 166 x 134 mm. This line pressure reducer is available in the following versions: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a gas purity of 5.0 with a stainless steel diaphragm. SS321 (1.4541)</p> |
|
|
|
|
| 4170 |
|
<p>Working pressure reducer Vulkan AD 35 nitrogen 0 - 10 bar for AM 35, single-stage design, with safety pressure gauge according to DIN EN ISO 5171. Maximum inlet pressure: 20 bar. Output pressure: 0 - 10 bar, adjustable. Maximum output: 50 Nm³/h air at 10 bar outlet pressure. Inlet: G1/2" male thread, threaded connection according to DIN EN 560. Outlet: G3/8" male thread, threaded connection according to DIN EN 560. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 89 x 166 x 134 mm. This line pressure reducer is available in the following versions: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a gas purity of 5.0 with a stainless steel diaphragm. SS321 (1.4541)</p> |
|
|
|
|
| 4177 |
|
<p>Vulkan L10/2N line pressure reducer for compressed air G1/2RHak both sides 0 - 1.5 bar, two-stage design, with safety pressure gauges according to DIN EN ISO 5171. Maximum inlet pressure: 20 bar. Output pressure: 0 - 1.5 bar, adjustable. Maximum output: 5 Nm³/h air at 1.5 bar outlet pressure. Inlet: external thread G1/2RHak, Outlet: external thread G1/2RHak, Inlet pressure gauge: 0 - 40/20 bar, Outlet pressure gauge: 0 - 2.5/1.5 bar, Width x Height x Depth: 220 x 190 x 75 mm. This line pressure reducer is available in the following versions, among others: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with standard diaphragm. Optional (surcharge): - for Pure gases up to a gas purity of 5.0 with stainless steel membrane SS321 (1.4541) Special outlet screw connection: Standard: - external thread G1/2" RHk on both sides according to EN 56 Options (surcharge): Order number Gas purity/Membrane Inlet/outlet screw connection 107564 for technical gases up to 4.5, with standard membrane on both sides. external thread G1/2" RHk according to EN 560 107564-6M-6M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 6mm 107564-8M-8M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 8mm 107564-10M-15M for technical gases up to 4.5, with standard membrane on both sides. Compression fitting VA 10 mm 107564-12M-15M for technical gases up to 4.5, with standard membrane on both sides. Stainless steel compression fitting 12 mm 107564-15M-15M for technical gases up to 4.5, with standard membrane on both sides. Stainless steel compression fitting 15 mm 107564-18M-18M for technical gases up to 4.5, with standard membrane on both sides. Stainless steel compression fitting 18 mm 107564-MM for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. External thread G1/2" RHk according to EN 560 107564-MM-6M-6M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Stainless steel compression fitting 6 mm 107564-MM-8M-8M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 8mm stainless steel compression fitting 107564-MM-10M-10M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 10mm stainless steel compression fitting 107564-MM-12M-12M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 12mm stainless steel compression fitting 107564-MM-15M-15M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. 15mm stainless steel compression fitting 107564-MM-18M-18M for pure gases up to 5.0, with metal membrane SS321 (1.4541) on both sides. Compression fitting VA 18 mm</p> |
|
|
|
|
| 4223 |
|
<p>Working pressure reducer Vulkan AD 35 nitrogen 0 - 10 bar for AM 35, single-stage design, with safety pressure gauge according to DIN EN ISO 5171. Maximum inlet pressure: 20 bar. Output pressure: 0 - 10 bar, adjustable. Maximum output: 50 Nm³/h air at 10 bar outlet pressure. Inlet: G1/2" male thread, threaded connection according to DIN EN 560. Outlet: G3/8" male thread, threaded connection according to DIN EN 560. Outlet pressure gauge: 0 - 16/10 bar. Width x Height x Depth: 89 x 166 x 134 mm. This line pressure reducer is available in the following versions: Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with a standard diaphragm. Optional (surcharge): - for pure gases up to a gas purity of 5.0 with a stainless steel diaphragm. SS321 (1.4541)</p> |
|
|
|
|
| 6675 |
|
Vulkan L15 line pressure reducer for fuel gases G1/2RH, 0 - 1.5 bar<br />Standards & Design:<br /><br />single-stage design, with safety pressure gauges according to DIN ISO 5171, maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br /><br />Technical data:<br /><br />• maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />• outlet pressure, input: external thread G1/2RH according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br />• output pressure: 0 to 1<br /><br />Dimensions:<br /><br />width x height x depth: 200 x 200 x 75 mm |
|
|
|
|
| 6677 |
|
Vulkan L15 line pressure reducer for fuel gases G1/2RH, 0 - 1.5 bar<br />Standards & Design:<br /><br />single-stage design, with safety pressure gauges according to DIN ISO 5171, maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br /><br />Technical data:<br /><br />• maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />• outlet pressure, input: external thread G1/2RH according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br />• output pressure: 0 to 1<br /><br />Dimensions:<br /><br />width x height x depth: 200 x 200 x 75 mm |
|
|
|
|
| 6686 |
|
Vulkan L15 line pressure reducer for fuel gases G1/2RH, 0 - 1.5 bar<br />Standards & Design:<br /><br />single-stage design, with safety pressure gauges according to DIN ISO 5171, maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br /><br />Technical data:<br /><br />• maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />• outlet pressure, input: external thread G1/2RH according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br />• output pressure: 0 to 1<br /><br />Dimensions:<br /><br />width x height x depth: 200 x 200 x 75 mm |
|
|
|
|
| 6696 |
|
Vulkan L15 line pressure reducer for fuel gases G1/2RH, 0 - 1.5 bar<br />Standards & Design:<br /><br />single-stage design, with safety pressure gauges according to DIN ISO 5171, maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br /><br />Technical data:<br /><br />• maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />• outlet pressure, input: external thread G1/2RH according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br />• output pressure: 0 to 1<br /><br />Dimensions:<br /><br />width x height x depth: 200 x 200 x 75 mm |
|
|
|
|
| 6703 |
|
Vulkan L15 line pressure reducer for fuel gases G1/2RH, 0 - 1.5 bar<br />Standards & Design:<br /><br />single-stage design, with safety pressure gauges according to DIN ISO 5171, maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br /><br />Technical data:<br /><br />• maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />• outlet pressure, input: external thread G1/2RH according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br />• output pressure: 0 to 1<br /><br />Dimensions:<br /><br />width x height x depth: 200 x 200 x 75 mm |
|
|
|
|
| 6704 |
|
<p>Vulkan L15 line pressure reducer for fuel gases G1/2RH, 0 - 1.5 bar<br>Standards & Design:<br><br>single-stage design, with safety pressure gauges according to DIN ISO 5171, maximum inlet pressure: 20 bar, output pressure: 0 to 1<br>according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br><br>Technical data:<br><br>• maximum inlet pressure: 20 bar, output pressure: 0 to 1<br>• outlet pressure, input: external thread G1/2RH according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br>• output pressure: 0 to 1<br><br>Dimensions:<br><br>width x height x depth: 200 x 200 x 75 mm</p> |
|
|
|
|
| 6709 |
|
Vulkan L15 line pressure reducer for fuel gases G1/2RH, 0 - 1.5 bar<br />Standards & Design:<br /><br />single-stage design, with safety pressure gauges according to DIN ISO 5171, maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br /><br />Technical data:<br /><br />• maximum inlet pressure: 20 bar, output pressure: 0 to 1<br />• outlet pressure, input: external thread G1/2RH according to EN 560, output: external thread G1/2RH according to EN 560, input pressure gauge: 0 to 40/20 bar, output pressure gauge: 0 to 2<br />• output pressure: 0 to 1<br /><br />Dimensions:<br /><br />width x height x depth: 200 x 200 x 75 mm |
|
|
|
|
| 6717 |
|
Tapping Points: Pressure Reducer Vulkan E10F Flowmeter LabLine Forming Gas 34 Nl/min. Completely chrome-plated with metal diaphragms for gas purity 5.0, based on ISO 2503<br />Standards & Design:<br /><br />Class 20<br />single-stage design, with flowmeter for monitoring the exact flow rate in Nl/min<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 20 bar<br />• Output pressure: 4<br />• Inlet: G 3/8 LHk U-nut according to DIN EN 560<br />• Outlet: 6mm double clamp ring, stainless steel<br /><br />Dimensions:<br /><br />Width x Height x Depth: 120 x 210 x 65 mm |
|
|
|
|
| 6718 |
|
Tapping Points: Pressure Reducer Vulkan E10F Flowmeter LabLine Forming Gas 34 Nl/min. Completely chrome-plated with metal diaphragms for gas purity 5.0, based on ISO 2503<br />Standards & Design:<br /><br />Class 20<br />single-stage design, with flowmeter for monitoring the exact flow rate in Nl/min<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 20 bar<br />• Output pressure: 4<br />• Inlet: G 3/8 LHk U-nut according to DIN EN 560<br />• Outlet: 6mm double clamp ring, stainless steel<br /><br />Dimensions:<br /><br />Width x Height x Depth: 120 x 210 x 65 mm |
|
|
|
|
| 6720 |
|
Tapping Points: Pressure Reducer Vulkan E10F Flowmeter LabLine Forming Gas 34 Nl/min. Completely chrome-plated with metal diaphragms for gas purity 5.0, based on ISO 2503<br />Standards & Design:<br /><br />Class 20<br />single-stage design, with flowmeter for monitoring the exact flow rate in Nl/min<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 20 bar<br />• Output pressure: 4<br />• Inlet: G 3/8 LHk U-nut according to DIN EN 560<br />• Outlet: 6mm double clamp ring, stainless steel<br /><br />Dimensions:<br /><br />Width x Height x Depth: 120 x 210 x 65 mm |
|
|
|
|
| 6721 |
|
Tapping Points: Pressure Reducer Vulkan E10F Flowmeter LabLine Forming Gas 34 Nl/min. Completely chrome-plated with metal diaphragms for gas purity 5.0, based on ISO 2503<br />Standards & Design:<br /><br />Class 20<br />single-stage design, with flowmeter for monitoring the exact flow rate in Nl/min<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 20 bar<br />• Output pressure: 4<br />• Inlet: G 3/8 LHk U-nut according to DIN EN 560<br />• Outlet: 6mm double clamp ring, stainless steel<br /><br />Dimensions:<br /><br />Width x Height x Depth: 120 x 210 x 65 mm |
|
|
|
|
| 6722 |
|
Tapping Points: Pressure Reducer Vulkan E10F Flowmeter LabLine Forming Gas 34 Nl/min. Completely chrome-plated with metal diaphragms for gas purity 5.0, based on ISO 2503<br />Standards & Design:<br /><br />Class 20<br />single-stage design, with flowmeter for monitoring the exact flow rate in Nl/min<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 20 bar<br />• Output pressure: 4<br />• Inlet: G 3/8 LHk U-nut according to DIN EN 560<br />• Outlet: 6mm double clamp ring, stainless steel<br /><br />Dimensions:<br /><br />Width x Height x Depth: 120 x 210 x 65 mm |
|
|
|
|
| 6723 |
|
Tapping Points: Pressure Reducer Vulkan E10F Flowmeter LabLine Forming Gas 34 Nl/min. Completely chrome-plated with metal diaphragms for gas purity 5.0, based on ISO 2503<br />Standards & Design:<br /><br />Class 20<br />single-stage design, with flowmeter for monitoring the exact flow rate in Nl/min<br />according to DIN EN 560<br /><br />Technical data:<br /><br />• Maximum inlet pressure: 20 bar<br />• Output pressure: 4<br />• Inlet: G 3/8 LHk U-nut according to DIN EN 560<br />• Outlet: 6mm double clamp ring, stainless steel<br /><br />Dimensions:<br /><br />Width x Height x Depth: 120 x 210 x 65 mm |
|
|
|
|
| 12223 |
|
Working pressure reducer Vulkan AD 35 for fuel gases 0 - 10 bar for AM 35<br />
Standards & Design:<br />
<br />
single-stage design, with safety pressure gauge according to DIN EN ISO 5171<br />
according to DIN EN 560<br />
<br />
Technical data:<br />
<br />
• Maximum inlet pressure: 20 bar<br />
• Output pressure: 0 - 10 bar<br />
• Outlet pressure gauge: 0 - 16/10 bar<br />
<br />
Performance:<br />
<br />
• Maximum output: 50 Nm³/h<br />
• at 10 bar outlet pressure<br />
<br />
Connections:<br />
<br />
• Inlet connection: External thread G1/2RHak according to DIN EN 560<br />
• Outlet connection: External thread G3/8RHak according to DIN EN 560<br />
<br />
Dimensions:<br />
<br />
Width x Height x Depth: 89 x 166 x 134 mm<br />
<br />
Variants & options:<br />
<br />
• Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with a standard membrane<br />
• Optional (surcharge): - for pure gases up to a gas purity of 5.0 with a stainless steel membrane<br />
• SS321 (1.4541) |
|
|
|
|
| 12224 |
|
Working pressure reducer Vulkan AD 35 for fuel gases 0 - 10 bar for AM 35<br />
Standards & Design:<br />
<br />
single-stage design, with safety pressure gauge according to DIN EN ISO 5171<br />
according to DIN EN 560<br />
<br />
Technical data:<br />
<br />
• Maximum inlet pressure: 20 bar<br />
• Output pressure: 0 - 10 bar<br />
• Outlet pressure gauge: 0 - 16/10 bar<br />
<br />
Performance:<br />
<br />
• Maximum output: 50 Nm³/h<br />
• at 10 bar outlet pressure<br />
<br />
Connections:<br />
<br />
• Inlet connection: External thread G1/2RHak according to DIN EN 560<br />
• Outlet connection: External thread G3/8RHak according to DIN EN 560<br />
<br />
Dimensions:<br />
<br />
Width x Height x Depth: 89 x 166 x 134 mm<br />
<br />
Variants & options:<br />
<br />
• Gas purity/diaphragm: Standard: - for technical gases up to a gas purity of 4.5 with a standard membrane<br />
• Optional (surcharge): - for pure gases up to a gas purity of 5.0 with a stainless steel membrane<br />
• SS321 (1.4541) |
|
|
|
|