Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
unit_name |
| 3428 |
|
according to drawing no. 95 100 130, with inlet pressure gauge and shut-off valve,Inlet pressure max: 12 bar<br />Outlet pressure: fixed at approx. 0.5 - 0.7 bar<br />Inlet: 7/16" x 28 NS2<br />Output: compression fitting 4 mm Ms nickel-plated<br />Inlet pressure gauge: 0 - 16 bar<br />Output pressure gauge: without (no connection available)<br />With flyer provided by Linde - Linde #43586000<br />Accessory pack: bag with 3 O-rings #11207000<br /><br />Minimum order quantity 300 pieces |
|
|
|
|
|
| 3429 |
|
single stage, with safety gauges acc. to ISO 5171inlet pressure max: 60 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max: 90 Nm³/h compressed air at 20 bar outlet pressure<br />in- and outlet: G3/8 RH female<br />inlet gauge: 0- 100/60 bar<br />outlet gauge: 0 – 40/20 bar <br />width x height x depth: 220 x 200 x 75 mm <br />with label on regulator |
|
|
|
|
|
| 3430 |
|
einstufige Bauart, mit Sicherheitsmanometern nach ISO 5171, Eingangsdruck max: 40 bar<br />Ausgangsdruck: 0 – 20 bar regelbar<br />Leistung max: 90 Nm³/h Druckluft bei 20 bar Hinterdruck <br />Ein- und Ausgang: Klemmring Ms 12 mm<br />ohne Eingangsmanometer<br />Ausgangsmanometer: 0 – 40/20 bar senkrecht<br />Breite x Höhe x Tiefe: 220 x 200 x 75 mm <br />mit Typenschild auf Druckminderer, mit Werkszeugnis 2.2 Bedienungsanleitung, Etikett mit Lindenummer/öl- und fettfrei auf Folie und Karton |
|
|
|
|
|
| 3436 |
|
In-line regulator for non aggressive gasesnot to use for: He/H2/C2H2/C3H8/CH4/C2H2<br />inlet pressure: max. 40 bar<br />working pressure : 0 - 20 bar adjustable<br />membrane : PTFE coatet<br />inlet gauge: without <br />working gauge : acc. to ISO 5171, 0- 40/20 bar<br />inlet an doutlet connection: 18 mm brass two ferrule compression type fitting<br />flow : max. 90 m3/h<br />free of oil- and grease<br />width x height x depth: 220 x 200 x 75 mm <br />With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "N", additional sticker on foil: "No cost-free redemption when foil is damaged "<br />The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br />Test report and test report 2.2 |
|
|
|
|
|
| 3437 |
|
<p>single stage, inlet pressure: max. 40 bar</p><p>working pressure : 0 - 20 bar adjustable<br><br>diaphragm: PTFE coatet<br><br>inlet gauge: without <br><br>working gauge : acc. to ISO 5171, 0- 40/20 bar<br><br>inlet an doutlet connection: 18 mm brass two ferrule compression type fitting<br><br>flow : max. 90 m3/h compresse air at 20 bar working pressure<br><br>free of oil- and grease<br><br>width x height x depth: 220 x 200 x 75 mm <br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
|
| 3438 |
|
In-line regulator, single stage,inlet pressure: max. 40 bar<br />working pressure : 0 - 20 bar adjustable<br />membrane : PTFE coatet<br />inlet gauge: without <br />working gauge : acc. to ISO 5171, 0- 40/20 bar<br />inlet an doutlet connection: 18 mm brass two ferrule compression type fitting<br />flow : max. 90 m3/h<br />free of oil- and grease<br />width x height x depth: 220 x 200 x 75 mm <br />With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br />The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br />Test report and test report 2.2 |
|
|
|
|
|
| 3452 |
|
<p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,</p><p>with shut off valve<br><br>inlet pressure max: 200 bar<br><br>outlet pressure: 0 - 30 Nl/min. (0 – 10 bar) adjustable<br><br>flow max: 30 Nl/min. at 10 bar outlet pressure <br><br>inlet connection: W 21,8x1/14 LH nut acc. to DIN 477-1, no. 1<br><br>outlet connection: G 3/8 LHk x 9 mm tail-piece acc. EN560<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 30 Nl/min.<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3453 |
|
<p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,</p><p>with shut off valve<br><br>inlet pressure max: 200 bar<br><br>outlet pressure: 0 - 50 Nl/min. (0 – 10 bar) adjustable<br><br>flow max: 50 Nl/min. at 10 bar outlet pressure <br><br>inlet connection: W 21,8x1/14 LH nut acc. to DIN 477-1, no. 1<br><br>outlet connection: G 3/8 LHk x 9 mm tail-piece acc. EN560<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 50 Nl/min.<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3477 |
|
acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0-10 bar<br />flow: 0 – 20 Nl/min. adjustable<br />Inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 – 315/200 bar<br />outlet gauge: 0 – 20 Nl/min. double scale Ar/CO2 (0 - 10 bar)<br />width x height x depth: 210 x 230 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3478 |
|
acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171, with shut off valve,inlet pressure max: 200 bar<br />outlet pressure: 0 – 10 bar <br />flow: 0 – 30 Nl/min. adjustable<br />inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 30 Nl/min. (0 - 10 bar)<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde tape |
|
|
|
|
|
| 3479 |
|
acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0-10 bar<br />flow: 0 – 20 Nl/min. adjustable<br />Inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 – 315/200 bar<br />outlet gauge: 0 – 30 Nl/min. double scale Ar/CO2 (0 - 10 bar)<br />width x height x depth: 210 x 230 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3488 |
|
according to ISO 2503, class 3,single stage with high-pressure compensation, with safety gauges according to ISO 5171, including shut off valveinlet pressure max.: 300 bar<br />working pressure: 0 - 10 bar adjustable <br />flow max. 48 Nm³/h compressed air at 10 bar working pressure<br />inlet connection: W 30x2 RH acc. to DIN 477-5, no. 54<br />outlet connection: G 1/4 RH x 6 mm acc. to EN 560<br />cylinder gauge 0 - 400/300 bar<br />working gauge: 0 - 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3489 |
|
acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:300 bar<br />outlet pressure: 10 - 100 bar adjustable<br />flow max:380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 24,32x1/14 RH male DIN 477-1, no. 10<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 160/100 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3490 |
|
acc. to ISO 2503, single stage with safety gauges acc. to ISO5171inlet pressure max: 300 bar<br />outlet pressure: 10 - 300 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 24,32x1/14 RH male DIN 477-1, no. 10<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3491 |
|
acc. to ISO 2503, class3, with high pressure compensation, single stage with safety gauges acc. to DIN ISO 5171inlet pressure max:300 bar<br />outlet pressure: 0 – 10 bar adjustable<br />flow max: 48 Nm³/h at 10 bar outlet pressure<br />inlet connection: W 30x2LHk nut acc. to DIN 477-5, Nr. 57<br />outlet connection: G 3/8 LHk x 9mm tail-piece acc. to DIN EN 560<br />inlet gauge: 0 – 400 / 300 bar<br />working gauge: 0 – 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3492 |
|
acc. to ISO 2503, class 5, single stage, with high pressure compensation for constant working pressure, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 300 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max.: 75 Nm³/h air at 10 bar working pressure<br />Inlet connection: W30x2LH nut acc. to DIN 477-5 no. 57<br />outlet connection: G 3/8 LHk x 9 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 400/300 bar<br />working gauge: 0 - 40/20 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3493 |
|
<p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,</p><p>with shut off valve<br><br>inlet pressure max: 200 bar<br><br>outlet pressure: 0 - 50 Nl/min. (0 – 10 bar) adjustable<br><br>flow max: 50 Nl/min. at 10 bar outlet pressure <br><br>inlet connection: W 30x2 LH nut acc. to DIN 477-5 no. 57<br><br>outlet connection: G 3/8 LHk x 9 mm tail-piece acc. EN560<br><br>inlet gauge: 0 – 400/300 bar<br><br>working gauge: 0 – 50 Nl/min.<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3494 |
|
<p>acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar</p><p>outlet pressure: 0 – 60 bar adjustable<br><br>flow max: 140 Nm³/h at 60 bar working pressure<br><br>inlet connection: W30x2 RHf nut acc. to DIN 477-5, no. 54<br><br>outlet connection: G 1/4RHak acc. to EN560<br><br>inlet gauge: 0 – 400/300 bar<br><br>working gauge: 0 – 100/60 bar<br><br>width x height x depth: 210 x 210 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3495 |
|
acc. to ISO 2503, single stage with safety gauges acc. to ISO 5171inlet pressure max:300 bar<br />outlet pressure: 10 - 100 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 21,8x1/14 RH male DIN 477-1, no. 6<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 160/100 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3496 |
|
acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max: 300 bar<br />outlet pressure: 10 - 300 bar adjustable<br />flow max:380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 21,8x1/14 RH male DIN 477-1, no. 6<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3497 |
|
according to ISO 2503, class 3, adiabatic compression tested, single stage with high-pressure compensation, with safety gauges according to ISO 5171, including shut off valveinlet pressure max.: 300 bar<br />working pressure: 0 - 10 bar adjustable <br />flow max. 48 Nm³/h compressed air at 10 bar working pressure<br />inlet connection: W 30x2 RH acc. to DIN 477-5, no. 59<br />outlet connection: G 1/4 RH x 6 mm acc. to EN 560<br />cylinder gauge 0 - 400/300 bar<br />working gauge: 0 - 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3498 |
|
acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:300 bar<br />outlet pressure: 10 - 100 bar adjustable<br />flow max:380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 59<br />outlet connection: G3/4RHf male DIN 477-1, no. 9<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 160/100 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3502 |
|
<p>acc to ISO2503, single stage, with flowmeter for exact control of the flow in Nl/min, TÜV – approved following Pressure equipment Directive 97/23/EG with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 300 bar</p><p>outlet pressure: 1,5 bar pre adjusted<br><br>flow: 2 – 23 Nl/min. adjustable<br><br>inlet: W 30x2 LH nut acc. to DIN 477-5<br><br>outlet: G 3/8 LHk x 9 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 400/300 bar<br><br>width x height x depth:: 210 x 230 x 75 mm</p> |
|
|
|
|
|
| 3503 |
|
acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171, with shut off valve,inlet pressure max: 300 bar<br />outlet pressure: 0 – 10 bar <br />flow: 0 – 30 Nl/min. adjustable<br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 30 Nl/min. (0 - 10 bar)<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde tape |
|
|
|
|
|
| 6840 |
|
Vulkan F15/200 Effect LabLine nitrogen cylinder pressure reducer 0-1.5 bar, fully chrome-plated with a metal diaphragm for gas purity 5.0, with pre-pressure compensation for constant back pressure under all operating conditions<br />Standards & Design:<br /><br />single-stage design, with shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br />according to DIN 477-1 No<br /><br />Functional elements:<br /><br />• shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br /><br />Technical data:<br /><br />• maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br />• outlet pressure: 0-1<br />• output: 8 Nm³/h compressed air at 1<br />• Inlet: W24<br />• outlet: 6 mm stainless steel compression fitting<br /><br />Dimensions:<br /><br />Width x Height x Depth: 210 x 190 x 75 mm |
|
|
|
|
|
| 6841 |
|
<p>Vulkan F15/200 Effect LabLine nitrogen cylinder pressure reducer 0-1.5 bar, fully chrome-plated with a metal diaphragm for gas purity 5.0, with pre-pressure compensation for constant back pressure under all operating conditions<br>Standards & Design:<br><br>single-stage design, with shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br>according to DIN 477-1 No<br><br>Functional elements:<br><br>• shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br><br>Technical data:<br><br>• maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br>• outlet pressure: 0-1<br>• output: 8 Nm³/h compressed air at 1<br>• Inlet: W24<br>• outlet: 6 mm stainless steel compression fitting<br><br>Dimensions:<br><br>Width x Height x Depth: 210 x 190 x 75 mm</p> |
|
|
|
|
|
| 6843 |
|
Vulkan F15/200 Effect LabLine nitrogen cylinder pressure reducer 0-1.5 bar, fully chrome-plated with a metal diaphragm for gas purity 5.0, with pre-pressure compensation for constant back pressure under all operating conditions<br />Standards & Design:<br /><br />single-stage design, with shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br />according to DIN 477-1 No<br /><br />Functional elements:<br /><br />• shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br /><br />Technical data:<br /><br />• maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br />• outlet pressure: 0-1<br />• output: 8 Nm³/h compressed air at 1<br />• Inlet: W24<br />• outlet: 6 mm stainless steel compression fitting<br /><br />Dimensions:<br /><br />Width x Height x Depth: 210 x 190 x 75 mm |
|
|
|
|
|
| 6846 |
|
<p>Vulkan F15/200 Effect LabLine nitrogen cylinder pressure reducer 0-1.5 bar, fully chrome-plated with a metal diaphragm for gas purity 5.0, with pre-pressure compensation for constant back pressure under all operating conditions<br>Standards & Design:<br><br>single-stage design, with shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br>according to DIN 477-1 No<br><br>Functional elements:<br><br>• shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br><br>Technical data:<br><br>• maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br>• outlet pressure: 0-1<br>• output: 8 Nm³/h compressed air at 1<br>• Inlet: W24<br>• outlet: 6 mm stainless steel compression fitting<br><br>Dimensions:<br><br>Width x Height x Depth: 210 x 190 x 75 mm</p> |
|
|
|
|
|
| 6951 |
|
acc to EN 13918, class 10, single stage, with flowmeter for exact control of the flow in Nl/min, TÜV – approved following Pressure equipment Directive 97/23/EG with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 300 bar<br />outlet pressure: 1,5 bar pre adjusted<br />flow: 4 – 32 Nl/min. adjustable<br />inlet: W 30x2 RH nut acc. to DIN 477-5<br />outlet: G 1/4 RHk x 6 mm tail-piece acc. EN 560<br />inlet gauge: 0 – 400/300 bar<br />width x height x depth:: 210 x 230 x 75 mm |
|
|
|
|
|
| 12802 |
|
|
|
|
|
|
|
| 12850 |
|
Tapping point regulator Vulkan LabLine E10, single stage. Chrome-plated brass body, stainless steel diaphragm, EPDM seals. Gas purity up to 5.0. Safety gauges acc. to DIN EN ISO 5171. Leakage rate 1×10⁻⁶ mbar·l/s. Inlet pressure max 20 bar. Outlet pressure 0–10 bar (adjustable). Max. flow 40 Nm³/h at 10 bar back pressure. Inlet: G 3/8 RH (right-hand) nut acc. to EN 560. Outlet: stainless steel clamp ring fitting 6 mm. LP gauge: 0–16 bar. Dimensions: 120 × 180 × 65 mm, weight 1.0 kg. |
|
|
|
|
|
| 12869 |
|
Tapping point regulator Vulkan LabLine E10F for oxygen, single stage with integrated flowmeter and regulating valve for precise flow control. Chrome-plated brass body, stainless steel diaphragm, EPDM seals. Gas purity up to 5.0. Leakage rate 1×10⁻⁶ mbar·l/s. Inlet pressure max 200 bar. Outlet pressure 5.0 bar (fixed). Flow range 1.0–15.0 Nl/min (adjustable). Inlet: G 3/8 RH (right-hand) nut acc. to EN 560. Outlet: stainless steel clamp ring fitting 6 mm. Dimensions: 120 × 220 × 65 mm, weight 1.0 kg. |
|
|
|
|
|
| 13274 |
|
In-line regulator Vulkan LabLine L10, single stage, chrome-plated body with stainless steel diaphragm for gas purity up to 5.0. With safety gauges acc. to DIN EN ISO 5171. Inlet pressure max 20 bar, outlet pressure 0–10 bar adjustable. Max. flow 45 Nm³/h at 10 bar. Inlet: clamp ring 8 mm. Outlet: clamp ring 8 mm. Dimensions: 200 × 190 × 75 mm, 1.5 kg. |
|
|
|
|
|
| 13280 |
|
In-line regulator Vulkan LabLine L15, single stage, chrome-plated body with stainless steel diaphragm for gas purity up to 5.0. With safety gauges acc. to DIN EN ISO 5171. Inlet pressure max 20 bar, outlet pressure 0–1.5 bar adjustable. Max. flow 8 Nm³/h at 1.5 bar. Inlet: clamp ring 8 mm. Outlet: clamp ring 8 mm. Dimensions: 200 × 190 × 75 mm, 1.5 kg. |
|
|
|
|
|
| 13286 |
|
In-line regulator Vulkan LabLine L10/2, double stage, chrome-plated body with stainless steel diaphragm for gas purity up to 5.0. With safety gauges acc. to DIN EN ISO 5171. Inlet pressure max 20 bar, outlet pressure 0–10 bar adjustable. Max. flow 30 Nm³/h at 10 bar. Inlet: clamp ring 8 mm. Outlet: clamp ring 8 mm. Dimensions: 240 × 190 × 75 mm, 2.0 kg. |
|
|
|
|
|
| 13292 |
|
In-line regulator Vulkan LabLine L15/2, double stage, chrome-plated body with stainless steel diaphragm for gas purity up to 5.0. With safety gauges acc. to DIN EN ISO 5171. Inlet pressure max 20 bar, outlet pressure 0–1.5 bar adjustable. Max. flow 8 Nm³/h at 1.5 bar. Inlet: clamp ring 8 mm. Outlet: clamp ring 8 mm. Dimensions: 240 × 190 × 75 mm, 2.0 kg. |
|
|
|
|
|