Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
unit_name |
| 6840 |
|
Vulkan F15/200 Effect LabLine nitrogen cylinder pressure reducer 0-1.5 bar, fully chrome-plated with a metal diaphragm for gas purity 5.0, with pre-pressure compensation for constant back pressure under all operating conditions<br />Standards & Design:<br /><br />single-stage design, with shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br />according to DIN 477-1 No<br /><br />Functional elements:<br /><br />• shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br /><br />Technical data:<br /><br />• maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br />• outlet pressure: 0-1<br />• output: 8 Nm³/h compressed air at 1<br />• Inlet: W24<br />• outlet: 6 mm stainless steel compression fitting<br /><br />Dimensions:<br /><br />Width x Height x Depth: 210 x 190 x 75 mm |
|
|
|
|
|
| 6841 |
|
<p>Vulkan F15/200 Effect LabLine nitrogen cylinder pressure reducer 0-1.5 bar, fully chrome-plated with a metal diaphragm for gas purity 5.0, with pre-pressure compensation for constant back pressure under all operating conditions<br>Standards & Design:<br><br>single-stage design, with shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br>according to DIN 477-1 No<br><br>Functional elements:<br><br>• shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br><br>Technical data:<br><br>• maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br>• outlet pressure: 0-1<br>• output: 8 Nm³/h compressed air at 1<br>• Inlet: W24<br>• outlet: 6 mm stainless steel compression fitting<br><br>Dimensions:<br><br>Width x Height x Depth: 210 x 190 x 75 mm</p> |
|
|
|
|
|
| 6843 |
|
Vulkan F15/200 Effect LabLine nitrogen cylinder pressure reducer 0-1.5 bar, fully chrome-plated with a metal diaphragm for gas purity 5.0, with pre-pressure compensation for constant back pressure under all operating conditions<br />Standards & Design:<br /><br />single-stage design, with shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br />according to DIN 477-1 No<br /><br />Functional elements:<br /><br />• shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br /><br />Technical data:<br /><br />• maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br />• outlet pressure: 0-1<br />• output: 8 Nm³/h compressed air at 1<br />• Inlet: W24<br />• outlet: 6 mm stainless steel compression fitting<br /><br />Dimensions:<br /><br />Width x Height x Depth: 210 x 190 x 75 mm |
|
|
|
|
|
| 6846 |
|
<p>Vulkan F15/200 Effect LabLine nitrogen cylinder pressure reducer 0-1.5 bar, fully chrome-plated with a metal diaphragm for gas purity 5.0, with pre-pressure compensation for constant back pressure under all operating conditions<br>Standards & Design:<br><br>single-stage design, with shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br>according to DIN 477-1 No<br><br>Functional elements:<br><br>• shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br><br>Technical data:<br><br>• maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br>• outlet pressure: 0-1<br>• output: 8 Nm³/h compressed air at 1<br>• Inlet: W24<br>• outlet: 6 mm stainless steel compression fitting<br><br>Dimensions:<br><br>Width x Height x Depth: 210 x 190 x 75 mm</p> |
|
|
|
|
|
| 7108 |
|
Vulkan F15/200 Effect LabLine nitrogen cylinder pressure reducer 0-1.5 bar, fully chrome-plated with a metal diaphragm for gas purity 5.0, with pre-pressure compensation for constant back pressure under all operating conditions<br />Standards & Design:<br /><br />single-stage design, with shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br />according to DIN 477-1 No<br /><br />Functional elements:<br /><br />• shut-off valve, with safety gauges according to DIN EN ISO 5171, maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br /><br />Technical data:<br /><br />• maximum inlet pressure: 200 bar, adjustable outlet pressure: 0-1<br />• outlet pressure: 0-1<br />• output: 8 Nm³/h compressed air at 1<br />• Inlet: W24<br />• outlet: 6 mm stainless steel compression fitting<br /><br />Dimensions:<br /><br />Width x Height x Depth: 210 x 190 x 75 mm |
|
|
|
|
|
| 12850 |
|
Tapping point regulator Vulkan LabLine E10, single stage. Chrome-plated brass body, stainless steel diaphragm, EPDM seals. Gas purity up to 5.0. Safety gauges acc. to DIN EN ISO 5171. Leakage rate 1×10⁻⁶ mbar·l/s. Inlet pressure max 20 bar. Outlet pressure 0–10 bar (adjustable). Max. flow 40 Nm³/h at 10 bar back pressure. Inlet: G 3/8 RH (right-hand) nut acc. to EN 560. Outlet: stainless steel clamp ring fitting 6 mm. LP gauge: 0–16 bar. Dimensions: 120 × 180 × 65 mm, weight 1.0 kg. |
|
|
|
|
|
| 12869 |
|
Tapping point regulator Vulkan LabLine E10F for oxygen, single stage with integrated flowmeter and regulating valve for precise flow control. Chrome-plated brass body, stainless steel diaphragm, EPDM seals. Gas purity up to 5.0. Leakage rate 1×10⁻⁶ mbar·l/s. Inlet pressure max 200 bar. Outlet pressure 5.0 bar (fixed). Flow range 1.0–15.0 Nl/min (adjustable). Inlet: G 3/8 RH (right-hand) nut acc. to EN 560. Outlet: stainless steel clamp ring fitting 6 mm. Dimensions: 120 × 220 × 65 mm, weight 1.0 kg. |
|
|
|
|
|