Result
| product_id |
short_description |
full_description |
meta_keywords |
meta_description |
search_words |
promo_text |
unit_name |
| 3428 |
|
according to drawing no. 95 100 130, with inlet pressure gauge and shut-off valve,Inlet pressure max: 12 bar<br />Outlet pressure: fixed at approx. 0.5 - 0.7 bar<br />Inlet: 7/16" x 28 NS2<br />Output: compression fitting 4 mm Ms nickel-plated<br />Inlet pressure gauge: 0 - 16 bar<br />Output pressure gauge: without (no connection available)<br />With flyer provided by Linde - Linde #43586000<br />Accessory pack: bag with 3 O-rings #11207000<br /><br />Minimum order quantity 300 pieces |
|
|
|
|
|
| 3429 |
|
single stage, with safety gauges acc. to ISO 5171inlet pressure max: 60 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max: 90 Nm³/h compressed air at 20 bar outlet pressure<br />in- and outlet: G3/8 RH female<br />inlet gauge: 0- 100/60 bar<br />outlet gauge: 0 – 40/20 bar <br />width x height x depth: 220 x 200 x 75 mm <br />with label on regulator |
|
|
|
|
|
| 3430 |
|
einstufige Bauart, mit Sicherheitsmanometern nach ISO 5171, Eingangsdruck max: 40 bar<br />Ausgangsdruck: 0 – 20 bar regelbar<br />Leistung max: 90 Nm³/h Druckluft bei 20 bar Hinterdruck <br />Ein- und Ausgang: Klemmring Ms 12 mm<br />ohne Eingangsmanometer<br />Ausgangsmanometer: 0 – 40/20 bar senkrecht<br />Breite x Höhe x Tiefe: 220 x 200 x 75 mm <br />mit Typenschild auf Druckminderer, mit Werkszeugnis 2.2 Bedienungsanleitung, Etikett mit Lindenummer/öl- und fettfrei auf Folie und Karton |
|
|
|
|
|
| 3436 |
|
In-line regulator for non aggressive gasesnot to use for: He/H2/C2H2/C3H8/CH4/C2H2<br />inlet pressure: max. 40 bar<br />working pressure : 0 - 20 bar adjustable<br />membrane : PTFE coatet<br />inlet gauge: without <br />working gauge : acc. to ISO 5171, 0- 40/20 bar<br />inlet an doutlet connection: 18 mm brass two ferrule compression type fitting<br />flow : max. 90 m3/h<br />free of oil- and grease<br />width x height x depth: 220 x 200 x 75 mm <br />With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "N", additional sticker on foil: "No cost-free redemption when foil is damaged "<br />The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br />Test report and test report 2.2 |
|
|
|
|
|
| 3437 |
|
<p>single stage, inlet pressure: max. 40 bar</p><p>working pressure : 0 - 20 bar adjustable<br><br>diaphragm: PTFE coatet<br><br>inlet gauge: without <br><br>working gauge : acc. to ISO 5171, 0- 40/20 bar<br><br>inlet an doutlet connection: 18 mm brass two ferrule compression type fitting<br><br>flow : max. 90 m3/h compresse air at 20 bar working pressure<br><br>free of oil- and grease<br><br>width x height x depth: 220 x 200 x 75 mm <br><br>With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, additional sticker on foil: "No cost-free redemption when foil is damaged "<br><br>The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br><br>Test report and test report 2.2</p> |
|
|
|
|
|
| 3438 |
|
In-line regulator, single stage,inlet pressure: max. 40 bar<br />working pressure : 0 - 20 bar adjustable<br />membrane : PTFE coatet<br />inlet gauge: without <br />working gauge : acc. to ISO 5171, 0- 40/20 bar<br />inlet an doutlet connection: 18 mm brass two ferrule compression type fitting<br />flow : max. 90 m3/h<br />free of oil- and grease<br />width x height x depth: 220 x 200 x 75 mm <br />With manufacturer's declaration, instruction manual, in food grade shrink wrap with sticker with Linde number / free of oil- and grease on box, individually wrapped in foam-lined box, with linde tape, "Glass-fork" symbol (according to Regulation (EC) 1935/2004, Annex II) on foil and box, code letter "O", additional sticker on foil: "No cost-free redemption when foil is damaged "<br />The regulator fulfills the requirements of Regulation (EC) 1935/2004, Regulation (EC) 2023/2006 and LFGB and is approved for contact with food suitable gases.<br />Test report and test report 2.2 |
|
|
|
|
|
| 3452 |
|
<p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,</p><p>with shut off valve<br><br>inlet pressure max: 200 bar<br><br>outlet pressure: 0 - 30 Nl/min. (0 – 10 bar) adjustable<br><br>flow max: 30 Nl/min. at 10 bar outlet pressure <br><br>inlet connection: W 21,8x1/14 LH nut acc. to DIN 477-1, no. 1<br><br>outlet connection: G 3/8 LHk x 9 mm tail-piece acc. EN560<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 30 Nl/min.<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3453 |
|
<p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,</p><p>with shut off valve<br><br>inlet pressure max: 200 bar<br><br>outlet pressure: 0 - 50 Nl/min. (0 – 10 bar) adjustable<br><br>flow max: 50 Nl/min. at 10 bar outlet pressure <br><br>inlet connection: W 21,8x1/14 LH nut acc. to DIN 477-1, no. 1<br><br>outlet connection: G 3/8 LHk x 9 mm tail-piece acc. EN560<br><br>inlet gauge: 0 – 315 /200 bar<br><br>working gauge: 0 – 50 Nl/min.<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3477 |
|
acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0-10 bar<br />flow: 0 – 20 Nl/min. adjustable<br />Inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 – 315/200 bar<br />outlet gauge: 0 – 20 Nl/min. double scale Ar/CO2 (0 - 10 bar)<br />width x height x depth: 210 x 230 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3478 |
|
acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171, with shut off valve,inlet pressure max: 200 bar<br />outlet pressure: 0 – 10 bar <br />flow: 0 – 30 Nl/min. adjustable<br />inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 315/200 bar<br />working gauge: 0 – 30 Nl/min. (0 - 10 bar)<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde tape |
|
|
|
|
|
| 3479 |
|
acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar<br />outlet pressure: 0-10 bar<br />flow: 0 – 20 Nl/min. adjustable<br />Inlet connection: W 21,8x1/14 RH nut acc. to DIN 477-1, no. 6<br />outlet connection: G 1/4 RHk x 6 mm tailpiece acc. to EN 560<br />inlet gauge: 0 – 315/200 bar<br />outlet gauge: 0 – 30 Nl/min. double scale Ar/CO2 (0 - 10 bar)<br />width x height x depth: 210 x 230 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3488 |
|
according to ISO 2503, class 3,single stage with high-pressure compensation, with safety gauges according to ISO 5171, including shut off valveinlet pressure max.: 300 bar<br />working pressure: 0 - 10 bar adjustable <br />flow max. 48 Nm³/h compressed air at 10 bar working pressure<br />inlet connection: W 30x2 RH acc. to DIN 477-5, no. 54<br />outlet connection: G 1/4 RH x 6 mm acc. to EN 560<br />cylinder gauge 0 - 400/300 bar<br />working gauge: 0 - 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3489 |
|
acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:300 bar<br />outlet pressure: 10 - 100 bar adjustable<br />flow max:380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 24,32x1/14 RH male DIN 477-1, no. 10<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 160/100 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3490 |
|
acc. to ISO 2503, single stage with safety gauges acc. to ISO5171inlet pressure max: 300 bar<br />outlet pressure: 10 - 300 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 24,32x1/14 RH male DIN 477-1, no. 10<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3491 |
|
acc. to ISO 2503, class3, with high pressure compensation, single stage with safety gauges acc. to DIN ISO 5171inlet pressure max:300 bar<br />outlet pressure: 0 – 10 bar adjustable<br />flow max: 48 Nm³/h at 10 bar outlet pressure<br />inlet connection: W 30x2LHk nut acc. to DIN 477-5, Nr. 57<br />outlet connection: G 3/8 LHk x 9mm tail-piece acc. to DIN EN 560<br />inlet gauge: 0 – 400 / 300 bar<br />working gauge: 0 – 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3492 |
|
acc. to ISO 2503, class 5, single stage, with high pressure compensation for constant working pressure, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 300 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max.: 75 Nm³/h air at 10 bar working pressure<br />Inlet connection: W30x2LH nut acc. to DIN 477-5 no. 57<br />outlet connection: G 3/8 LHk x 9 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 400/300 bar<br />working gauge: 0 - 40/20 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3493 |
|
<p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,</p><p>with shut off valve<br><br>inlet pressure max: 200 bar<br><br>outlet pressure: 0 - 50 Nl/min. (0 – 10 bar) adjustable<br><br>flow max: 50 Nl/min. at 10 bar outlet pressure <br><br>inlet connection: W 30x2 LH nut acc. to DIN 477-5 no. 57<br><br>outlet connection: G 3/8 LHk x 9 mm tail-piece acc. EN560<br><br>inlet gauge: 0 – 400/300 bar<br><br>working gauge: 0 – 50 Nl/min.<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3494 |
|
<p>acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar</p><p>outlet pressure: 0 – 60 bar adjustable<br><br>flow max: 140 Nm³/h at 60 bar working pressure<br><br>inlet connection: W30x2 RHf nut acc. to DIN 477-5, no. 54<br><br>outlet connection: G 1/4RHak acc. to EN560<br><br>inlet gauge: 0 – 400/300 bar<br><br>working gauge: 0 – 100/60 bar<br><br>width x height x depth: 210 x 210 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p> |
|
|
|
|
|
| 3495 |
|
acc. to ISO 2503, single stage with safety gauges acc. to ISO 5171inlet pressure max:300 bar<br />outlet pressure: 10 - 100 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 21,8x1/14 RH male DIN 477-1, no. 6<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 160/100 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3496 |
|
acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max: 300 bar<br />outlet pressure: 10 - 300 bar adjustable<br />flow max:380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 21,8x1/14 RH male DIN 477-1, no. 6<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3497 |
|
according to ISO 2503, class 3, adiabatic compression tested, single stage with high-pressure compensation, with safety gauges according to ISO 5171, including shut off valveinlet pressure max.: 300 bar<br />working pressure: 0 - 10 bar adjustable <br />flow max. 48 Nm³/h compressed air at 10 bar working pressure<br />inlet connection: W 30x2 RH acc. to DIN 477-5, no. 59<br />outlet connection: G 1/4 RH x 6 mm acc. to EN 560<br />cylinder gauge 0 - 400/300 bar<br />working gauge: 0 - 16/10 bar<br />width x height x depth: 210 x 190 x 75 mm <br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3498 |
|
acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:300 bar<br />outlet pressure: 10 - 100 bar adjustable<br />flow max:380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 59<br />outlet connection: G3/4RHf male DIN 477-1, no. 9<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 160/100 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape |
|
|
|
|
|
| 3502 |
|
<p>acc to ISO2503, single stage, with flowmeter for exact control of the flow in Nl/min, TÜV – approved following Pressure equipment Directive 97/23/EG with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 300 bar</p><p>outlet pressure: 1,5 bar pre adjusted<br><br>flow: 2 – 23 Nl/min. adjustable<br><br>inlet: W 30x2 LH nut acc. to DIN 477-5<br><br>outlet: G 3/8 LHk x 9 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 400/300 bar<br><br>width x height x depth:: 210 x 230 x 75 mm</p> |
|
|
|
|
|
| 3503 |
|
acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171, with shut off valve,inlet pressure max: 300 bar<br />outlet pressure: 0 – 10 bar <br />flow: 0 – 30 Nl/min. adjustable<br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 30 Nl/min. (0 - 10 bar)<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde tape |
|
|
|
|
|
| 6951 |
|
acc to EN 13918, class 10, single stage, with flowmeter for exact control of the flow in Nl/min, TÜV – approved following Pressure equipment Directive 97/23/EG with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 300 bar<br />outlet pressure: 1,5 bar pre adjusted<br />flow: 4 – 32 Nl/min. adjustable<br />inlet: W 30x2 RH nut acc. to DIN 477-5<br />outlet: G 1/4 RHk x 6 mm tail-piece acc. EN 560<br />inlet gauge: 0 – 400/300 bar<br />width x height x depth:: 210 x 230 x 75 mm |
|
|
|
|
|