SELECT 
  cscart_product_descriptions.product_id, 
  cscart_product_descriptions.short_description, 
  IF(
    cscart_product_descriptions.short_description = '' 
    OR cscart_product_descriptions.short_description IS NULL, 
    cscart_product_descriptions.full_description, 
    ''
  ) AS full_description, 
  cscart_product_descriptions.meta_keywords, 
  cscart_product_descriptions.meta_description, 
  cscart_product_descriptions.search_words, 
  cscart_product_descriptions.promo_text, 
  cscart_product_descriptions.unit_name 
FROM 
  cscart_product_descriptions 
WHERE 
  cscart_product_descriptions.product_id IN (
    3492, 3496, 3490, 3494, 6951, 3502, 3503, 
    3493, 3498, 3428, 3433, 3432, 12594, 
    12609, 12424, 12554, 12536, 12546, 
    13127, 12464, 12624, 12654, 13148, 
    13153
  ) 
  AND cscart_product_descriptions.lang_code = 'en'

Query time 0.00118

JSON explain

{
  "query_block": {
    "select_id": 1,
    "cost_info": {
      "query_cost": "24.25"
    },
    "table": {
      "table_name": "cscart_product_descriptions",
      "access_type": "range",
      "possible_keys": [
        "PRIMARY",
        "product_id"
      ],
      "key": "PRIMARY",
      "used_key_parts": [
        "product_id",
        "lang_code"
      ],
      "key_length": "9",
      "rows_examined_per_scan": 24,
      "rows_produced_per_join": 24,
      "filtered": "100.00",
      "index_condition": "((`test2_gaseus`.`cscart_product_descriptions`.`product_id` in (3492,3496,3490,3494,6951,3502,3503,3493,3498,3428,3433,3432,12594,12609,12424,12554,12536,12546,13127,12464,12624,12654,13148,13153)) and (`test2_gaseus`.`cscart_product_descriptions`.`lang_code` = 'en'))",
      "cost_info": {
        "read_cost": "21.85",
        "eval_cost": "2.40",
        "prefix_cost": "24.25",
        "data_read_per_join": "109K"
      },
      "used_columns": [
        "product_id",
        "lang_code",
        "short_description",
        "full_description",
        "meta_keywords",
        "meta_description",
        "search_words",
        "promo_text",
        "unit_name"
      ]
    }
  }
}

Result

product_id short_description full_description meta_keywords meta_description search_words promo_text unit_name
3428 according to drawing no. 95 100 130, with inlet pressure gauge and shut-off valve,Inlet pressure max: 12 bar<br />Outlet pressure: fixed at approx. 0.5 - 0.7 bar<br />Inlet: 7/16" x 28 NS2<br />Output: compression fitting 4 mm Ms nickel-plated<br />Inlet pressure gauge: 0 - 16 bar<br />Output pressure gauge: without (no connection available)<br />With flyer provided by Linde - Linde #43586000<br />Accessory pack: bag with 3 O-rings #11207000<br /><br />Minimum order quantity 300 pieces
3432 <p>appropriate electrical equipment,marking: Ex II 1 G D [EEx ia] IIC, </p><p>to alarm and control in case of pressure drop, to connect 2 solenoid valves (230v 50Hz) and contact gauges with inductive contact, with integrated optical and acoustical signal, connection of additional external alarm possible, complete in box with potential free contact to connect contact gauges in explosive areas of group II, <br><br>box must be installed outside the explosive area, <br><br>power supply: 230V/ 50Hz</p>
3433 <p>for connecting, monitoring and switching two contact pressure gauges with inductive contacts and two solenoid valves, with internal signal display "Gas type operation OK empty" for each channel, extraction side selectable, with "Empty message hold function" (alarm must be acknowledged),Inputs: 2 x inductive contact</p><p>Output: 2 x solenoid valve 230V 50Hz<br><br>with potential-free contacts,<br><br>completely in plastic housing<br><br>Width x height x depth: 300 x 230 x 190 mm<br><br>With operating instructions, CE declaration of conformity for the electrical part, electr. Execution according to current VDE and European regulations, affixed type plate with Linde logo, glass front pane with Linde logo, Linde type designation, affixed Linde lettering, individually packed in a carton, with Linde adhesive tape</p>
3490 acc. to ISO 2503, single stage with safety gauges acc. to ISO5171inlet pressure max: 300 bar<br />outlet pressure: 10 - 300 bar adjustable<br />flow max: 380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 24,32x1/14 RH male DIN 477-1, no. 10<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3492 acc. to ISO 2503, class 5, single stage, with high pressure compensation for constant working pressure, with safety gauges acc. to ISO 5171, with shut off valve,inlet pressure max.: 300 bar<br />outlet pressure: 0 – 20 bar adjustable<br />flow max.: 75 Nm³/h air at 10 bar working pressure<br />Inlet connection: W30x2LH nut acc. to DIN 477-5 no. 57<br />outlet connection: G 3/8 LHk x 9 mm tailpiece acc. to EN 560<br />inlet gauge: 0 - 400/300 bar<br />working gauge: 0 - 40/20 bar<br />width x height x depth: 210 x 210 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3493 <p>acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171,</p><p>with shut off valve<br><br>inlet pressure max: 200 bar<br><br>outlet pressure: 0 - 50 Nl/min. (0 – 10 bar) adjustable<br><br>flow max: 50 Nl/min. at 10 bar outlet pressure <br><br>inlet connection: W 30x2 LH nut acc. to DIN 477-5 no. 57<br><br>outlet connection: G 3/8 LHk x 9 mm tail-piece acc. EN560<br><br>inlet gauge: 0 – 400/300 bar<br><br>working gauge: 0 – 50 Nl/min.<br><br>width x height x depth: 210 x 190 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p>
3494 <p>acc to DIN EN ISO 2503, single stage, with high pressure compensation for a constant working pressure on falling inlet pressure with safety gauges acc. to DIN ISO 5171inlet pressure max: 200 bar</p><p>outlet pressure: 0 – 60 bar adjustable<br><br>flow max: 140 Nm³/h at 60 bar working pressure<br><br>inlet connection: W30x2 RHf nut acc. to DIN 477-5, no. 54<br><br>outlet connection: G 1/4RHak acc. to EN560<br><br>inlet gauge: 0 – 400/300 bar<br><br>working gauge: 0 – 100/60 bar<br><br>width x height x depth: 210 x 210 x 75 mm<br><br>with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape</p>
3496 acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max: 300 bar<br />outlet pressure: 10 - 300 bar adjustable<br />flow max:380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: W 21,8x1/14 RH male DIN 477-1, no. 6<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 315/200 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3498 acc. to ISO 2503, single stage with safety gauges acc. to EN562inlet pressure max:300 bar<br />outlet pressure: 10 - 100 bar adjustable<br />flow max:380 Nm³/h at 50 bar outlet pressure <br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 59<br />outlet connection: G3/4RHf male DIN 477-1, no. 9<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 160/100 bar<br />width x height x depth: 170 x 140 x 180 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde adhesive tape
3502 <p>acc to ISO2503, single stage, with flowmeter for exact control of the flow in Nl/min, TÜV – approved following Pressure equipment Directive 97/23/EG with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 300 bar</p><p>outlet pressure: 1,5 bar pre adjusted<br><br>flow: 2 – 23 Nl/min. adjustable<br><br>inlet: W 30x2 LH nut acc. to DIN 477-5<br><br>outlet: G 3/8 LHk x 9 mm tail-piece acc. EN 560<br><br>inlet gauge: 0 – 400/300 bar<br><br>width x height x depth:: 210 x 230 x 75 mm</p>
3503 acc to DIN EN ISO 2503, class 3, single stage, with safety gauges acc. to DIN ISO 5171, with shut off valve,inlet pressure max: 300 bar<br />outlet pressure: 0 – 10 bar <br />flow: 0 – 30 Nl/min. adjustable<br />inlet connection: W 30x2 RH nut acc. to DIN 477-5, no. 54<br />outlet connection: G 1/4RH x 6mm tail-piece<br />inlet gauge: 0 – 400/300 bar<br />working gauge: 0 – 30 Nl/min. (0 - 10 bar)<br />width x height x depth: 210 x 190 x 75 mm<br />with Linde-Logo stamped on body, with Linde operating manual and Linde tape
6951 acc to EN 13918, class 10, single stage, with flowmeter for exact control of the flow in Nl/min, TÜV – approved following Pressure equipment Directive 97/23/EG with high pressure compensation for constant working pressure with safety gauge acc. to ISO 5171, with shut off valveinlet pressure max: 300 bar<br />outlet pressure: 1,5 bar pre adjusted<br />flow: 4 – 32 Nl/min. adjustable<br />inlet: W 30x2 RH nut acc. to DIN 477-5<br />outlet: G 1/4 RHk x 6 mm tail-piece acc. EN 560<br />inlet gauge: 0 – 400/300 bar<br />width x height x depth:: 210 x 230 x 75 mm
12424 <p>Compact single-stage line pressure regulator according to ISO 2503 for technical, medical, corrosive, laboratory and high-purity gases. Inlet and outlet: 1/4" NPT-F thread or compression fitting. Outlet pressure gauge Ø50 mm according to DIN 837. 50 µm inlet filter and relief valve. Gas purity up to 6.0. Maximum inlet pressure up to 300 bar depending on standard; coding legend additionally defines inlet pressure classes L=70 bar, H=210 bar, 300=300 bar (brass only), 400=400 bar (stainless steel only). Outlet pressure ranges from 1.5 to 30 bar, special ranges up to 60 bar possible. Temperature range -40 to +70 °C. Body materials: chrome-plated brass, stainless steel or Monel. Membrane materials: stainless steel or Hastelloy. ECD suitable. Leak rate &lt; 1×10^-8 (helium). ATEX and PED compliant. Options include inlet gauge, shut-off or metering valve, self or external purge system, contact gauge or pressure transmitter.</p>
12464 <p>Compact single-stage pressure control station (manifold) for one cylinder, designed for technical, medical, corrosive, laboratory and high-purity gases. Equipped with one main pressure regulator, inlet and outlet pressure gauges (Ø 50 mm, DIN 837), 50 µm inlet filter and relief valve. Includes one stainless steel corrugated metal hose, 1,000 mm long, for cylinder connection. Completely mounted on a stainless steel base plate with fixing holes. Inlet: cylinder connection according to DIN 477 Part 1 or Part 5. Outlet: compression fitting or alternatively 1/4" NPT-F thread. Maximum inlet pressure up to 300 bar depending on standard. Outlet pressure ranges from 1.5 to 30 bar; special ranges up to 60 bar are possible. Temperature range: -40 to +70 °C. Body materials: chrome-plated brass, stainless steel or Monel. Membranes: stainless steel or Hastelloy. ECD suitable. Leak rate &lt; 1×10^-8 (helium). ATEX and PED compliant. Options include shut-off or metering valve, purge system and contact gauge or pressure transmitter.</p>
12536 Compact single-stage line pressure regulator type Thanos in accordance with ISO 2503 for technical, medical, corrosive, laboratory and high-purity gases. Features: compact design, high control accuracy, inlet and outlet: 1/4" NPT-F or according to customer requirements; outlet pressure gauge Ø 50 mm (DIN EN 837); 74 µm inlet filter; relief valve; gas purity up to 6.0; temperature range -20 to +60 °C; body materials: nickel-plated brass or stainless steel 316L; diaphragm: stainless steel 316L; seat: PCTFE; leak rate < 2×10⁻⁸ mbar·l/s (He); compliant with 2014/68/EU (PED) and 2014/34/EU (ATEX). Options: inlet pressure gauge, shut-off or metering valve, purge system (internal or external), contact gauge or pressure transmitter.
12546 Compact two-stage line pressure regulator type Thanos II in accordance with ISO 2503 for technical, medical, corrosive, laboratory and high-purity gases. Two-stage design provides absolutely constant outlet pressure even as inlet pressure fluctuates. Features: compact design, high control accuracy, inlet and outlet: 1/4" NPT-F or according to customer requirements; outlet pressure gauge Ø 50 mm (DIN EN 837); 74 µm inlet filter; relief valve; gas purity up to 6.0; temperature range -20 to +60 °C; body materials: nickel-plated brass or stainless steel 316L; diaphragm: stainless steel 316L; seat: PCTFE; leak rate < 2×10⁻⁸ mbar·l/s (He); compliant with 2014/68/EU (PED) and 2014/34/EU (ATEX). Options: inlet pressure gauge, shut-off or metering valve, purge system (internal or external), contact gauge or pressure transmitter.
12554 Compact two-stage line pressure regulator type Sigma II in accordance with ISO 2503 for technical, medical, corrosive, laboratory and high-purity gases. Two-stage design provides absolutely constant outlet pressure even as inlet pressure fluctuates. Features: compact design with high control accuracy; inlet and outlet: 1/4" NPT-F, alternatively compression fitting; outlet pressure gauge Ø 50 mm (DIN EN 837); 50 µm inlet filter; relief valve per stage; gas purity up to 6.0; temperature range -40 to +70 °C; body materials: chrome-plated brass, stainless steel or Monel; diaphragm: stainless steel or Hastelloy; seat: PCTFE; ECD compatible; ATEX compliant (94/9/EG); PED compliant (97/23/EG). Options: inlet pressure gauge Ø 50 mm, shut-off or metering valve, gas purging system (internal or external), contact gauge or pressure transmitter.
12594 Compact single-stage line fine pressure regulator type Omega I in accordance with ISO 2503 for technical, medical, corrosive, laboratory and high-purity gases. Designed for precise millibar-range outlet pressure control. Features: compact design with high control accuracy; inlet and outlet: 1/4" NPT-F, alternatively compression fitting; outlet pressure gauge Ø 63 mm; 50 µm inlet filter; relief valve; gas purity up to 6.0; temperature range -40 to +70 °C; body materials: chrome-plated brass, stainless steel or Monel; diaphragm: stainless steel or Hastelloy; seat: PCTFE; ECD compatible; ATEX compliant (94/9/EG); PED compliant (97/23/EG). Options: inlet pressure gauge, shut-off or metering valve, gas purging system (internal or external), contact gauge or pressure transmitter.
12609 Compact two-stage line fine pressure regulator type Omega II in accordance with ISO 2503 for technical, medical, corrosive, laboratory and high-purity gases. Two-stage design provides exceptionally stable millibar-range outlet pressure. Features: compact design with high control accuracy; inlet and outlet: 1/4" NPT-F, alternatively compression fitting; outlet pressure gauge Ø 63 mm; 50 µm inlet filter; 2 relief valves (one per stage); gas purity up to 6.0; temperature range -40 to +70 °C; body materials: chrome-plated brass, stainless steel or Monel; diaphragm: stainless steel or Hastelloy; seat: PCTFE; ECD compatible; ATEX compliant (94/9/EG); PED compliant (97/23/EG). Options: inlet pressure gauge, shut-off or metering valve, gas purging system (internal or external), contact gauge or pressure transmitter.
12624 Compact single-stage pressure control station (manifold) for two cylinders with manual changeover, designed for technical, medical, corrosive, laboratory and high-purity gases. Equipped with one main pressure regulator, inlet and outlet pressure gauges (Ø 50 mm, DIN 837), 50 µm inlet filter and relief valve. Includes 2 distribution blocks with shut-off valves for left and right cylinder changeover, and 2 stainless steel corrugated metal hoses (1,000 mm) for cylinder connection. Completely mounted on a stainless steel base plate with fixing holes. Inlet: cylinder connection according to DIN 477 Part 1 or Part 5. Outlet: compression fitting or alternatively 1/4" NPT-F thread. Maximum inlet pressure up to 300 bar depending on standard. Outlet pressure ranges from 1.5 to 30 bar; special ranges up to 60 bar. Temperature range: -40 to +70 °C. Body materials: chrome-plated brass, stainless steel or Monel. Diaphragm: stainless steel or Hastelloy. Seat: PCTFE. ECD suitable. Leak rate < 1×10⁻⁸ mbar·l/s (He). ATEX and PED compliant. Options: shut-off or metering valve, extension for more cylinders, purge system, contact gauge or pressure transmitter.
12654 Compact two-stage pressure control station (manifold) for two cylinders with manual changeover, designed for technical, medical, corrosive, laboratory and high-purity gases. Two-stage regulation ensures highly stable outlet pressure regardless of declining inlet pressure. Equipped with one main two-stage pressure regulator, inlet and outlet pressure gauges (Ø 50 mm, DIN 837), 50 µm inlet filter and relief valve per stage. Includes 2 distribution blocks with shut-off valves for left and right cylinder changeover, and 2 stainless steel corrugated metal hoses (1,000 mm) for cylinder connection. Completely mounted on a stainless steel base plate with fixing holes. Inlet: cylinder connection according to DIN 477 Part 1 or Part 5. Outlet: compression fitting or alternatively 1/4" NPT-F thread. Maximum inlet pressure up to 300 bar depending on standard. Outlet pressure ranges from 1.5 to 30 bar; special ranges up to 60 bar. Temperature range: -40 to +70 °C. Body materials: chrome-plated brass, stainless steel or Monel. Diaphragm: stainless steel or Hastelloy. Seat: PCTFE. ECD suitable. Leak rate < 1×10⁻⁸ mbar·l/s (He). ATEX and PED compliant. Options: shut-off or metering valve, extension for more cylinders, purge system, contact gauge or pressure transmitter.
13127 Manual manifold base station Vulkan LabLine BS 50/300 Effect, chrome-plated. Modular add-on system (Modula Vareo). Manual switching. Complete on stainless steel base plate: 1× distributing block, 1× manifold regulator H10 acc. to ISO 7291, 1× main shut-off valve, with purge valves. Inlet max 300 bar, outlet 0–10 bar. Max. flow 50 Nm³/h. Stainless steel diaphragm. Gas purity up to 5.0. Dimensions: 570 × 250 × 210 mm, 10 kg.
13148 Single-cylinder manifold station Vulkan LabLine SE 10/2 300 (with standard gauges), chrome-plated. Modular add-on system. Manual switching. Complete on stainless steel base plate: 1× HP shut-off valve, 1× manifold regulator H10/2 double stage acc. to ISO 7291, 1× main shut-off valve, 1× purge valve, 1× cylinder rack. Inlet max 300 bar, outlet 0–10 bar. Max. flow 30 Nm³/h at 10 bar. Stainless steel diaphragm, gas purity up to 5.0. Dimensions: 480 × 280 × 110 mm.
13153 Single-cylinder manifold station Vulkan LabLine SE 10/2 300 (with contact gauge (Reed switch)), chrome-plated. Modular add-on system. Manual switching. Complete on stainless steel base plate: 1× HP shut-off valve, 1× manifold regulator H10/2 double stage acc. to ISO 7291, 1× main shut-off valve, 1× purge valve, 1× cylinder rack. Inlet max 300 bar, outlet 0–10 bar. Max. flow 30 Nm³/h at 10 bar. Stainless steel diaphragm, gas purity up to 5.0. Dimensions: 480 × 280 × 110 mm.